Specifications

  • Product Name: Fire Rated 093V Expansion
  • Intumescent Tape Rating: 1 and 2 hours
  • Accommodates building movement up to / inch

Product Usage Instructions

Step 1: Before Installation

Snap chalk lines as a guide. Measure, cut, and dry fit the
bead.

Step 2: Prepare the Bead and Drywall

Coat both the bead and drywall with Trim-Tex 847 Spray
Adhesive.

Step 3: Install the Bead

Press the bead in place, applying pressure to the mud legs.

Step 4: Finish with Drywall Compound

Apply drywall compound to the installed bead to create a smooth
finish.

Step 5: Sanding and Final Touches

Remove tear-off strips prior to sanding. After sanding, perform
any final touch-ups as needed.

Frequently Asked Questions (FAQ)

Q: What is the fire rating of the intumescent tape?

A: The intumescent tape is rated for 1 and 2 hours of fire
resistance.

Q: How much building movement can the bead accommodate?

A: The flexible bead can accommodate up to / inch of building
movement.

Q: What adhesive should be used to coat the bead and

drywall?

A: Trim-Tex 847 Spray Adhesive is recommended for coating both
the bead and drywall.

Fire Rated 093V Expansion
Building out fire-rated control joints on wall assemblies using traditional methods is costly and time consuming. Our fire rated 093X-V expansion bead revolutionizes this process. Integrated intumescent tape rated for 1 and 2 hours, and the flexible bead accommodates up to / ” in building movement.

Installation Guide
Technical Specs /” /”
/”

Scan Below for Installation Video

Step 1:

Before Installation:
Snap chalk lines as a guide. Measure, cut and dry fit the bead.
Step 1:
Coat both the bead and drywall with Trim-Tex 847 Spray Adhesive.
Step 2:
Press the bead in place, applying pressure to the mud legs.
Step 3:
Staple every 6″-8″ using ½” staples.
Step 4:
Finish with drywall compound.
Step 5:
Remove tear-off strips prior to sanding.

Step 3: Step 5:

Step 2: Step 4: