Navien NPE-180A Condensing Water Heater User Manual

June 11, 2024
Navien

Navien-NPE-180A-Condensing-Water-Heater-User Manual

Model
NPE-180A/ 210A/ 240A
NPE-180S/ 210S/ 240S

Keep this manual near this water heater for future reference whenever maintenance or service is required.

The wetted surface of this product contacted by consumable water contains less than one quarter of one percent(0.25%) of lead by weight.

WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death.

  • Do not store or use gasoline or other flammable vapors – and liquids in the vicinity of this or any other appliance.
  • WHAT TO DO IF YOU SMELL GAS
    • Do not try to light any appliance.
    • Do not touch any electrical switch; do not use any phone in your building.
    • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
    • If you cannot reach your gas supplier, call the fire department.
  • Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Safety Information

The following safety symbols are used in this manual. Read and follow all safety instructions in this manual precisely to avoid unsafe operating conditions, fire, explosion, property damage, personal injury, or death. Keep this manual for future reference.

DANGER
Indicates an imminently hazardous situation which, if not avoided, could result in severe injury or death.

WARNING
Indicates a potential hazardous situation which, if not avoided, may result in injury or death.

CAUTION
Indicates a potentially hazardous situation that, if not avoided, could result in property damage.

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

  • A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.
    B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
    WHAT TO DO IF YOU SMELL GAS

    • Do not try to light any appliance.
    • Do not touch any electric switch; do not use any phone in your building.
    • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
    • If you cannot reach your gas supplier, call the fire department.
  • C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

  • D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

DANGER

To prevent burns:

  • Use the lowest operating temperature setting necessary to provide comfortably-hot water.
  • If your household has children or elderly or disabled residents, consider using a lower temperature setting.
  • Read all the instructions in this manual carefully before changing the temperature setting.
  • Feel the water before using it on children, the elderly, or the disabled.
  • If it is necessary to set the water heater above 125°F (52°C),have a temperature-limiting valve or mixing valve installed on the water heater.

This water heater is set to 120°F (49°C) at the factory for your safety and comfort. Increasing the temperature increases the risk of accidental scalding. Water temperatures at or above 125°F (52°C) can cause instant scalding, severe burns, or death.
Before you decide to change the temperature setting, read the following charts carefully.

Water Temperature| Time in which a young child can suffer a **full thickness (3rd degree) burn***
---|---
70°C (160°F)| Less than 1 second
60°C (140°F)| 1 second
55°C (130°F)| 10 second
49°C (120°F)| 10 minutes
37°C (100°F)| very low scald risk

Before setting the temperature at or above 125°F (52°C), consider installing a thermostatically-controlled mixing valve or temperaturelimiting valve. Contact a licensed plumber or your local plumbing authority for more information.

WARNING

  • Shut off the gas supply if the water heater is damaged.
    Have your installer or plumber show you the location of the gas shut off valve and demonstrate how to close the valve. If the water heater is damaged as a result of overheating, fire,flood, or any other reason, close the manual shut off valve and do not operate the water heater again until it has been inspected by a qualified technician.

  • Do not store or use gasoline or other flammable liquids near this water heater.
    Doing so may result in fire or explosion.

  • Do not place combustibles, such as newspapers or laundry, near the water heater or venting system.
    Doing so may result in a fire.

  • Do not place or use hair sprays, spray paints, or any other compressed gases near the water heater or venting system, including the vent termination.
    Doing so may result in fire or explosion.

  • Do not operate the water heater with the front cover opened.
    Doing so may result in fire or carbon monoxide (CO) poisoning, which may result in property damage, personal injury, or death.

  • Do not operate this water heater without proper venting.
    Doing so may result in fire or carbon monoxide (CO) poisoning, which may result in property damage, personal injury, or death. Inspect the vent termination and air intake supply annually to ensure proper operation of the water heater. Turn off and discontinue use of the water heaterif any of the vent pipes, vent elbows, or intake pipes are damaged in any way, separated at a joint, or show evidence of corrosion, rusting, or melting.

  • Do not touch the power cord or internal components of the water heater with wet hands.
    Doing so may result in electric shock.

CAUTION

  • Do not attempt to repair or replace any part of the water heater, unless it is specifically recommended in this manual.

  • For all other service, contact an authorized technician or licensed professional. Improper adjustments, alterations,service, or maintenance may lead to property damage, personal injury, or death and will void your warranty.

  • Do not operate the water heater if you feel something is wrong with it.
    Doing so may result in product damage or personal injury.

  • Do not allow children to operate or access the water heater.
    Doing so may result in product damage or personal injury.

  • Do not attempt to change the water temperature while the water heater is being used.
    Doing so may result in personal injury.

  • Do not turn on the water heater unless the water and gas supplies are fully opened.
    Doing so may damage the water heater.

  • Do not turn on the water if the cold water supply shutoff valve is closed.
    Doing so may damage the water heater.

  • Do not use this water heater for anything other than its intended purpose, as described in this manual.

  • Do not remove the front cover unless the power to the water heater is turned off or disconnected.
    Failure to do so may result in electric shock.

  • When servicing the controls, label all wires prior to disconnecting them.
    Failure to do so may result in wiring errors, which can lead to improper or dangerous operation.

  • Do not use unapproved replacement or accessory parts.
    Doing so may result in improper or dangerous operation and will void the manufacturer’s warranty.

  • Do not place anything in or around the vent terminals, such as a clothes line, that could obstruct the air flow in or out of the water heater.

  • This water heater has been approved for use in the USA and Canada only.
    Using the water heater in any other country will void the manufacturer’s warranty.

  • Should overheating occur or the gas supply fail to shut off, turn off the manual gas valve to the appliance.

  • Do not use this appliance if any part has been under water.
    Immediately call a qualifed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

About the Water Heater

Description of the Water Heater
The NPE-series water heater is available in 6 models: NPE-180A,NPE-180S, NPE- 210A. NPE-210S, NPE-240A and NPE-240S.

The main features are as follows:

  • Potable domestic hot water, combination space heating, and commercial applications
  • Maximum temperature: 182°F (83°C)
  • Dual stainless steel Heat Exchangers with stainless steel piping
  • Built-in pump and 0.4 US gallon (1.5 liter) Buffer Tank for internal or external recirculation (“A” model only)

Parts of the Water Heater

Navien-NPE-180A-Condensing-Water-Heater-User Manual-1

Bottom View

Navien-NPE-180A-Condensing-Water-Heater-User Manual-2

# Description Remark
a Pump Drain Port “A” model only
b Gas Inlet
c Hot Water Outlet Connection
d Recirculation Inlet “A” model only
e Condensate Water Clean-out
f Inlet Water Filter
g Cold Water Inlet Connection
h Condensate Drain Connection

The Front Panel
The front panel allows you to adjust the water temperature and view the operating status or error codes. Remove the protective sheet from the front panel before using it.

Navien-NPE-180A-Condensing-Water-Heater-User Manual-4

Operating the Water Heater

Turning the Water Heater On or Off
To turn the water heater on or off, press the Power button.

When the power is on, the temperature will appear on the front panel display.

Adjusting the Water Temperature

WARNING
Before adjusting the water temperature, read “To prevent burns:” on page 4 carefully. Water above 120°F can cause instant scalding, severe burns, or death.

The water heater is set to 120°F (49°C) by default. To adjust the water temperature:

  1. Make sure that all hot water faucets are closed, and ensure that the internal circulator and any external circulating pumps are off.
    Note If a hot water faucet is open, you can adjust the temperature only from 98-110°F (37-43°C).

  2. Press the + (Up) or – (Down) buttons until the desired temperature appears on the display. You can adjust the temperature while the display is flashing. Once the display stops flashing, the temperature setting is stored.

Note The water heater will retain your settings during a power outage.

You can adjust the temperature by the below 10-degree increments, depending on the temperature range:

Temperature range Adjusting the water temperature
98°F-120°F (Fahrenheit mode) 36°C-50°C (Celsius mode) 1°F or 0.5°C increments
120°F-140°F (Fahrenheit mode) 50°C-60°C (Celsius mode) Press for 2 seconds to

adjust in 5°F or 2°C increments

The water heater will not provide hot water instantly at the hot water faucet unless a recirculation line has been installed from the furthest fixture back to the water heater. For “A” models, the unit must be set to “external recirculation” mode.

Using Commercial Mode
To use water above 140°F (60°C) (up to 182°F (83°C)), you can use Commercial Mode.

  • To enter Commercial Mode: Press the up (+) and down (-) button simultaneously for 10 seconds. “HIGH” appears on the display.
  • To exit Commercial Mode: Press the up (+) and down (-) button simultaneously for 10 seconds. “LoW” appears on the display.

Note

  • To adjust the temperature, press the up (+) button for 5 seconds to adjust in 10°F (5°C) increments.
  • Commercial Warranty Applies when this mode is used. Refer to the Warranty for more details.
Viewing Basic Information

To view information about the water heater, press the Information button.

Press the + or – buttons to switch between the information types.

To exit information mode, press the Reset button.

Resetting the Water Heater
If an error message appears, you can try resetting the water heater to resolve the problem. To reset the water heater, press the Reset button.

If resetting the water heater does not solve the problem, refer to the Troubleshooting section of this manual or contact Technical Support at 1-800-519-8794.

Maintaining the Water Heater

Cleaning the Water Heater

CAUTION
Make sure the water heater is turned off and the power supply is disconnected before cleaning the water heater. The water heater may remain hot for several minutes after it is turned off.
To prevent burns, wait until the water heater has cooled down before cleaning.

To clean the water heater, wipe the outside with a damp cloth. Use a non- acidic, non-abrasive cleaner to remove any surface stains.
The front panel is moisture resistant, but it is not waterproof. Keep it as dry as possible.

Draining the Water Heater

You need to drain the water heater before performing maintenance tasks, such as cleaning the inlet water filter, or to prevent the water heater from freezing when it will not be used for an extended period.
Refer to the “2.2 Parts of the Water Heater” on page 6 for details about part locations.

To drain the water heater:

  1. Place a bucket under the water heater, to collect the residual water inside the water heater.
  2. Press the Power button on the front panel to turn off the power to the water heater.
  3. Close the gas valve.
  4. Close the water supply valve on the inlet to the water heater. If there is no valve, turn off the water supply at the water main.
  5. Open all hot water faucets completely. The water that remains in the plumbing lines will drain out.
  6. Remove the recirculation inlet filter from the bottom of the water heater (“A” model only).Navien-NPE-180A-Condensing-Water-Heater-User Manual-14
  7. Open the pump drain plug (“A” model only).
  8. Remove the cold water inlet filter.
  9. Allow the residual water to drain from the water heater.
  10. When the water is completely drained, reinsert the recirculation inlet filter and the cold water inlet filter, and then close the pump drain plug.
  11. To refill the water heater follow the steps of “Draining the Water Heater” in reverse.
Flushing the Heat Exchanger

CAUTION
Flushing the Heat Exchanger is a somewhat complicated procedure. Read the following instructions carefully beforeattempting this procedure. If you are uncertain about any of the steps in the procedure, contact an authorized technician or licensed professional. Keep in mind that improper maintenance can void your warranty.

Refer to the “2.2 Parts of the Water Heater” on page 6 for details about part locations.

Before flushing the Heat Exchanger, gather the following items:

  • A bucket that is 5 gallons or larger
  • Cleaning solution diluted with water
  • 3 hoses
  • A water circulation pump

To flush the Heat Exchanger:

Navien-NPE-180A-Condensing-Water-Heater-User Manual-15

  1. Press the Power button on the front panel to turn off the water heater.
  2. Disconnect the power supply to the water heater.
  3. Close the “C” and “D” valves on the hot and cold water lines.
  4. Connect one tube to the “A” valve and place the free end in the bucket.
  5. Connect one of the tubes to the circulation pump outlet and the cold water line at the “B” valve.
  6. Connect one tube to the circulation pump inlet and place the free end in the bucket.
  7. Pour the cleaning solution into the bucket.
  8. Open both “A” and “B” valves.
  9. Turn on the circulation pump and allow the solution to circulate through the water heater for at least 45 minutes.
  10. Rinse the cleaning solution from the water heater:
    • Remove the free end of the drain tube from the bucket and place it in the condensate drain or laundry tub (wherever the water heater drains).
    • Close the “B” valve and open the “D” valve. Do not open the “C” valve yet.
    • Allow water to flow through the water heater for 5 minutes.
    • Close the “A” valve and open the “C” valve.
  11. Disconnect all tubes.
  12. Remove the cold water inlet filter from the water heater and clean out any residue.
  13. Reinsert the filter and ensure the filter cap is securely tightened.
  14. Reconnect the power supply to the Water Heater.
  15. Press the Power button on the front panel to turn on the water heater.

Cleaning the Inlet Water Filter and Recirculation Inlet Filter

To clean the filters:

  1. Drain the water heater. Refer to “4.2 Draining the Water Heater” on page 10.
  2. While the filters are removed, rinse it with clean running water (cold) and, if necessary, scrub it clean with a brush.
  3. Reinsert and tighten the filters.
  4. Refill the water heater. Refer to “4.2 Draining the Water Heater” on page 10.

Cleaning the Air Intake Filter
If the air intake filter becomes clogged by dust or lint, the water heater will cease to operate and “Error Code 10” will appear on the front panel display. To properly maintain the water heater, you should clean the air intake filter every 3-4 months.

To clean the air intake filter:

  1. Press the Power button on the front panel to turn off the water heater.
  2. Disconnect the power supply to the water heater.
  3. Remove the front cover of the water heater.
  4. Remove the screw that secures the air intake filter (the filter is located at the top left of the water heater).
  5. Pull the filter out of the water heater.
  6. Remove the filter from the plastic assembly and clean it with a toothbrush and clean running water.
  7. Allow the filter to dry completely.
  8. Reinsert the filter into the plastic assembly.
  9. Place the filter assembly back into the water heater and secure it with the screw.
  10. Replace the front cover.
  11. Reconnect the power supply to the water heater.
  12. Press the Power button on the front panel to turn on the water heater.

Protecting the Water Heater from Freezing

CAUTION
Damage due to freezing is not covered by the Navien limited warranty.

  • Freezing damage is most likely to occur due to back drafting caused by negative pressure in the building. This is not a manufacturing defect, and therefore, Navien will not warrantany damages due to freezing. The installer is responsible for ensuring that there is sufficient make-up air to avoid such a situation and the owner is responsible for ensuring that protection against freezing is maintained.
  • To avoid freezing issues, we strongly recommend the use of a direct vent exhaust and intake system. Your installer should ensure that the exhaust vent pipe and the air intake pipe are both connected directly from the collars on the top of the water heater to the outdoors. This type of vent system minimizes air movement within the water heater.
  • This water heater has an optional recirculation mode that is used for freeze protection. This mode should prevent the water heater from freezing, even if the intake air duct is not vented directly.
  • The water heater is designed for indoor or outdoor installation. However, it should not be installed outdoors in areas that are prone to freezing temperatures.

To ensure that the water heater does not freeze, follow these guidelines:

  • Do not unplug the power supply cord, except for routine maintenance. The water heater has a freeze protection function that requires electricity. The freeze protection function will operate regardless of whether or not the power is turned on or off, as long as the electric supply is still connected.
  • Do not close the gas valve, except for routine maintenance, as this will limit additional freeze protection (“A” model only).
  • If the power or gas supplies must be disconnected for an extended period, drain the water heater. Freezing damage may occur if there is a loss of power or an interruption in the gas supply to the water heater.
  • If the water heater will not be used for an extended period, drain the water heater.

If hot water will not flow and you suspect that the water heater is frozen, follow these steps:

  1. Press the Power button on the front panel to turn off the water heater.
  2. Close the gas valve.
  3. Open the hot water faucet that is closest to the water heater.
  4. Use a hair dryer or a portable electric heater to heat up both the primary and secondary Heat Exchangers.
  5. Check every few minutes to see if water is running at the open faucet.
  6. When the water starts flowing again, check the water heater and piping for leaks. If you detect any leaks or the water heater is not operating properly, contact an authorized technician or licensed professional

Troubleshooting

Solving Basic Problems
If you experience a problem with the water heater, refer to the following chart for possible remedies. Error codes that appear on the front panel display are explained in the following section.
For minor problems, resetting the water heater may resolve the issue. To reset the water heater, press the Reset button on the front panel.

If resetting the water heater and attempting the remedies suggested below do not resolve the problem, contact an authorized technician, a licensed professional, or Technical Support at 1-800-519-8794 for service instructions.

Problem Possible Cause(s) What to do

No water comes out when the hot water tap is opened.

| ●    Is the cold water inlet filter clean?

●    Is an error code displayed on the front panel?

●    Is the water heater frozen?

| ●    Ensure that the shut–off valves on the hot and cold pipes are open.

●    If an error code is displayed, refer to “5.2 Understanding Error Codes” on page 16.

The water from the hot water faucet is cold or turns cold and stays cold.

| ●    Is the cold water inlet filter clean?

●    Is the hot water faucet open wide enough draw at least 0.5 gallons of water per minute (GPM) through the water heater?

●    Is an error code displayed on the front panel?

●    If there is an external recirculation system installed, is there a check valve on the recirculation return line?

|

●    Clean the cold water inlet filter. See

“4.4 Cleaning the Inlet Water Filter and Recirculation Inlet Filter” on page 12.

●    Open the hot water faucet completely.

●    If an error code is displayed, refer to “5.2 Understanding Error Codes” on page 16.

It takes too long for hot water to reach the fixtures.|

Are you using the external recirculation mode?

| Have a contractor install a recirculation return line from the furthest faucet back to the water heater.

The water is not hot enough.

|

Is the set temperature too low?

| ●    Check the water heater’s temperature setting. Refer to “3.2 Adjusting the Water Temperature” on page 8.

●    Check for cross plumbing between the cold and hot water lines.

The water is too hot.

|

Is the set temperature set too high?

| Check the water heater’s temperature setting. See “3.2 Adjusting the Water Temperature” on page 8.

Understanding Error Codes
When an error code appears on the front panel, refer to the following chart for a definition and possible remedy for the situation.

Error Code Reason Self-diagnostic / Action
E003 Ignition failure ●    Ensure that the main gas supply valve is open.
E004 False flame detection ●    Ensure that the electrical cord is properly

grounded.
E012| Flame loss| ●    Clean the intake air filter. See page 13.

●    Ensure that the electrical cord is properly grounded.

E016

|

Overheating of heat exchanger

| ●    Turn off the system for at least 30 minutes, and then restart it.

●    Clean the cold water inlet filter. See page 12.

●    Flush the heat exchanger. See page 11.

E030

| Exhaust overheating (the water heater shuts down when the flue temperature exceeds 149°F (65°C)| ●    Turn off the system for at least 30 minutes, and then restart it.

●    Clean the cold water inlet filter. See page 12.

●    Flush the heat exchanger. See page 11.

E046| Abnormal operation: limit control| Contact Technical Support at 1-800-519-8794.
E047| Abnormal operation: exhaust thermostat| Contact Technical Support at 1-800-519-8794.
E060| Abnormal operation: dual venturi| Contact Technical Support at 1-800-519-8794.
E109| Abnormal operation: fan motor| Clean the intake air filter. See page 13.
E110| Abnormal air pressure| ●    Ensure that the exhaust pipe is free of obstructions.

●    Clean the intake air filter. See page 13.

E407| Hot water outlet: thermistor open or short circuit| Contact Technical Support at 1-800-519-8794.
E421| Cold water inlet1: thermistor open or short circuit| Contact Technical Support at 1-800-519-8794.
E432| Cold water inlet2: thermistor open or short circuit| Contact Technical Support at 1-800-519-8794.
E434| Abnormal operation: water adjustment valve| Contact Technical Support at 1-800-519-8794.
E438| Abnormal operation: circulation pump| ●    External: Ensure that all water supply and return lines are open.

●    Internal: Check the direction of the 2-way valve.

E439| Abnormal operation: flow sensor| Contact Technical Support at 1-800-519-8794.
E441| Hot water inlet2: thermistor open or short circuit| Contact Technical Support at 1-800-519-8794.
E445| Abnormal operation: Bypass mixing valve| Contact Technical Support at 1-800-519-8794.
E515| Abnormal operation: PCB| Ensure that the electrical cord is properly grounded.
E517| Abnormal operation: DIP switch setting| Contact Technical Support at 1-800-519-8794.
E593| Abnormal operation: front panel key| Contact Technical Support at 1-800-519-8794.
E615| Abnormal operation: input and memory| Contact Technical Support at 1-800-519-8794.
E736| Abnormal operation: cascade communication| Contact Technical Support at 1-800-519-8794.
E760| Flushing/service alarm| Contact the installer to perform routine service.
E782| Abnormal operation: main panel communication| Contact Technical Support at 1-800-519-8794.

If any of these remedies do not resolve the problem, contact Technical Support at 1-800-519-8794.

LIMITED WARRANTY

NAVIEN AMERICA, INC.

Warranty Period
Navien products come with a limited warranty covering labor, parts and the heat exchanger. The following warranty periods begin to run from the date of original installation. The date of original installation must be provided to Navien, and upon request, proof of the original installation date must also be provided to Navien. When the product is installed in a new construction, the commencement date shall be dated upon which the end-user takes title to the property.

APPLICABLE WARRANTY PERIOD


Product

| Labor Warranty| Parts Warranty| Heat Exchanger Warranty
---|---|---|---
NPE Series Water Heater (Single Family Residential Use)| ****

1 year

| ****

5 years

| ****

15 years

NPE Series Water Heater (Commercial or Combi* Use)| ****

1 year

| ****

3 years

| ****

10 years

Combi refers to a combination potable water and space heating application.
Water heaters cannot be used in space heating only applications.

Warranty Claim Procedures
To obtain warranty repair service, the end user or homeower must contact the original installer of your Navien product. If the original installer cannot be identified, the end user or homeowner may contact Navien’s
Technical Administration Department at 800-519-8794. Proof of purchase is required to obtain warranty service.

Warranty Service

At its option, Navien will replace the defective component (part(s) or heat exchanger), in accordance with the terms of this Limited Warranty, if it fails in normal use and service during the Applicable Warranty Period identified above. The replacement component must be Navien original factory component. Navien, at its sole discretion, may replace the product with a new or refurbished product of comparable quality and design. The replacement component will be warranted only for the unexpired portion of the original component’s Applicable Warranty Period. Payment for labor in completing the warranty service is subject to Navien’s prior written approval and shall be subject to Navien’s schedule of approved labor allowances.

Warranty Exclusions

Navien’s Limited Warranty shall be void in the event of an occurrence of any of the following:

  • Improper installation, failure to install in strict compliance withthe Installation Manual procedures, installed by a non-licensed installer, and installation in violation of applicable rules, laws or building codes.

  • Product purchased through the internet, other e-commerce channels, or any installer that obtained the Product from a supplier or distributor not authorized by Navien.

  • Failure to perform regular maintenance, misuse, operation at settings other than those recommended or specified, non-compliance with instructions or guidelines set forth in the User’s Operation Manual.

  • Modification or alteration of the Product in any manner, including but not limited to, removal of any component or part, addition of any non-approved components, relocating or moving the Product from its original installation site, or any accidental or intentional damage to the Product.

  • Installation for non-recommended uses.

  • Any damage caused by local adverse conditions including but not limited to hard water deposits, lime or mineral build-up, operating in corrosive atmospheric elements.

  • Damage or problems caused by gas flow issues, electrical surges, flooding, fire, abnormal external temperature, and any other cause of damage not directly caused by a manufacturing defect.

  • Installer’s failure to fully comply with the Warranty Service and Return Policy procedures previously provided to Installer and as is available on Navien’s website. Such policies include but are not limited to the Installer’s failure to first contact Navien Technical
    Support while in front of the product for purposes of trouble shooting the identified problem or issue.
    Use of the NPE Series Water Heater for space heating only purposes shall void the warranty.

  • Performance problems caused by improper sizing of the water heater, the gas supply line, the venting connection, combustion air openings, electric service voltage, wiring, fusing or any other components, parts or specifications.

  • Improper conversion from natural gas to LP gas or LP gas to natural gas or attempt to operate with a type of gas not specified for the water heater.

  • Any damage, malfunction or failure caused by abuse, negligence, alteration, accident, fire, flood, freezing, wind, lightning and other acts of God.

  • Operating, using or storing the water heater in a corrosive or contaminated atmosphere or environment.

  • Operating the water heater at water temperatures outside the factory calibrated temperature limits and/or exceeding the maximum setting of the high limit control.

  • Operating the water heater when it is not supplied with potable water at all times.

  • Subjecting the heat exchanger to pressures or firing rates greater or lesser than those shown on the rating plate.

  • Installation at any location outside the United States and Canada.

  • Removal or alteration of the rating plate.

Other Terms: This Limited Warranty is subject further to the terms and conditions set forth herein and as may be further specified in the Terms and Conditions page located on Navien’s website at www.navienamerica.com.

WITH THE EXCEPTION OF THIS LIMITED WARRANTY, NAVIEN DISCLAIMS ANY OBLIGATION OR LIABILITY WITH RESPECT TO THE PRODUCTS OR THEIR SALE AND USE, AND NAVIEN NEITHER ASSUMES NOR AUTHORIZES THE ASSUMPTION OF, ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE PRODUCTS. THIS DISCLAIMER INCLUDES ANY OTHER WARRANTIES, EXPRESS, IMPLIED OR STATUTORY RESPECTING THE PRODUCTS OR ANY PARTS OR COMPONENTS THEREOF, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Navien’s total liability for any claim arising hereunder shall not exceed the purchase price which you paid for the Product.

NAVIEN SHALL NOT IN ANY EVENT BE LIABLE FOR INDIRECT, SPECIAL, CONSEQUENTIAL OR LIQUIDATED DAMAGES OR PENALTIES, INCLUDING CLAIMS FOR LOST REVENUE, PROFITS OR BUSINESS OPPORTUNITIES, EVEN IF NAVIEN HAD OR SHOULD HAVE HAD ANY KNOWLEDGE, ACTUAL OR CONSTRUCTIVE, OF THE POSSIBILITY OF SUCH DAMAGES.

Getting Service
If your water heater requires service, you have several options for getting service:

  • Contact Technical Support at 1-800-519-8794 or on the website: www.navienamerica.com.
    For warranty service, always contact Technical Support firt.

  • Contact the technician or professional who installed your water heater.

  • Contact a licensed professional for the affected system (for example, a plumber or electrician).

When you contact Technical Support, please have the following information at hand:

  • Model number
  • Serial number
  • Date purchased
  • Installation location and type
  • Error code, if any appears on the front panel display.

Navien America, Inc.
20 Goodyear lrvine, CA 92618 TEL +949-420-0420 FAX +949-420-0430 www.navienamerica.com

Download PDF:Navien NPE-180A Condensing Water Heater User Manual

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>