MITSUBISHI ELECTRIC PLFY-M25VEM6-E City Multi Fan Coils PLFY-M 4 Way Standard Cassette Instruction Manual

June 15, 2024
Mitsubishi Electric

MITSUBISHI ELECTRIC - logol

PLFY-M VEM6-E

INDOOR UNITS – 4-way cassette 900×900

city multi

Ideal for…

New design of 4-way cassette VEM model suits most commercial applications thanks to its elegance and syle. Its peculiar features are horizontal flow function, individually settable vanes and possibility to install 3D i-see sensor for top environment comfort control.

3D i-see sensor: Temperature sensor

3D i-see sensor is able to detect temperature distribution inside the room, making it possible to direct airflow to those areas which generally receive less air, making them more uncomfortable (too cold or too hot) for users.

Horizontal flow

This new indoor unit is capable of handling five vane positions, making it possible to achieve horizontal flow that spreads across the ceiling, maximizing the Coanda effect. This allows to avoid, if needed, direct airflow to users in the room, which can sometimes be uncomfortable.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Temperature sensor 2

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Temperature sensor 3

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Temperature sensor 4

Key Technologies

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Temperature sensor 5

3D i-see sensor: Direct/Indirect flow function

Optional 3D i-see sensor allows to detect and count users in the environment and their position. User can set either Direct or Indirect flow to occupied areas, with single control on four vanes.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Temperature sensor 6

3D i-see sensor: Energy saving

3D i-see sensor features allow to optimize comfort conditions and at the same time achieve energy saving. Thanks to the occupancy sensor the unit is able to automatically handle and reduce power output accordingly to users actually being present in the room or in certain areas of it. This feature is particularly helpful in those environments in which occupancy varies significantly during the day.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Temperature sensor 7

Optimum airflow

2-, 3-, 4-way airflow pattern selection
Three outlet options are available–bidirectional, three-way, and four way–to suit different types of installation. Select, for example, the four-way pattern for installation in the center of the room and three-way pattern for installation in the corner.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Temperature sensor 8

Individual vane angle settings
Vane direction can be changed or fixed from the remote controller to direct the supply air at or away from objects or occupants in the room.
The airflow direction of each vane can be set using the wired remote controller or wireless remote controller (PAR-SL101A-E).

  • Optional shuffle placement is required for 2- and 3-way patterns.

2-, 3-, 4-way airflow pattern selection
+
Individual vane angle settings
Combinations with individual vane settings enable an optimal outlet setting for each room layout to ensure even temperature distribution throughout each room. The result is uniformly comfortable air conditioning.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Temperature sensor 10

Equipped with high- and low-ceiling modes

Units are equipped with high- and low-ceiling operation modes that make it possible to switch the airflow volume to match the height of the room.
Being able to choose the optimum airflow volume helps optimize the breezy sensation felt throughout the room.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Temperature sensor 11

Airflow range

Model Airflow
pattern| M20-M80| M100/M125
---|---|---
High-ceiling
setting| Standard
setting| Low-ceiling
setting| High-ceiling
setting| Standard
setting| Low-ceiling
setting
4-way| 3.5 m| 2.7 m| 2.5 m| 4.5 m| 3.2 m| 2.7 m
3-way| 3.5 m| 3.0 m| 2.7 m| 4.5 m| 3.6 m| 3.0 m
2-way| 3.5m| 3.3m| 3.0 m| 4.5m| 4.0 m| 3.3m

Automatic air-speed adjustment

An automatic air-speed mode automatically adjusts airflow speed to maintain comfortable room conditions at all times. This setting automatically adjusts the air speed to conditions that match the room environment.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Key Technologies 1

Panel and control

The unit is supplied with PLP-6EA panel which does not include signal receiver. This component (PAR-SE9FA-E) can be installed as a corner accessory, as well as 3D i-See Sensor (PAC-SE1ME-E). The unit is compatible with all wired MA and ME remote controls and, if equipped with signal receiver, wireless remote controls. New PAR-SL101A-E is compatible with PLFY-M VEM, and presents numerous new features, such as weekly timer, backlit display, 0,5°C temperature setting and monitoring, as well as functions for 3D i-see sensor (optional).

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Panel and control 1

Connectable to Plasma Quad Connect
The optional Plasma Quad Connect PAC-SK51FT-E can be installed on the indoor units.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Panel and control 2

Simplified installation

Thanks to new temporary panel supports maintenance and installation operation are now easier for field technicians.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Panel and control 3

Also, panel weight has been reduced by 20% thanks to a new design.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Panel and control 4

A simple loosening of support screws allows the removal of the control box and corner accessories.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Panel and control 5

Electrical box wiring
After reviewing the power supply terminal position in the electrical box, the structure has been redesigned to improve connectivity. This makes complex wiring work easier.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Panel and control 6

Increased space for plumbing work
The top and bottom positions of the liquid and gas pipes have been reversed to allow the gas pipe work, which requires more effort, to be completed first. Further, through structural innovations related to the space around the pipes, the area for the spanner has been increased, thus improving liquid piping work and enabling it to be completed smoothly.

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - Panel and control 7

Technical specifications

MITSUBISHI ELECTRIC PLFY M25VEM6 E City Multi Fan Coils PLFY M 4 Way
Standard Cassette - icon 2

  • 1 Cooling/Heating capacity is the maximum value measured in the following conditions.
    Cooling: indoor 27°C (81°F) DB/19°C (66°F) WB, outdoor 35°C (95°F) BS. Heating: indoor 20°C (68°F) DB, outdoor 7°C (45°F) DB/6°C (43°F) WB.
  • 2 High-mid1-mid2-low setting
  • 3 Measured in anechoic chamber with 230V power supply.
Optional parts DESCRIPTION
PAC-SK51FT-E Plasma Quad Connect
PAC-SE1ME-E Corner 3D I-see Sensor for PLFY-M VEM-E
PLP-6EALM Panel with wireless remote controller

MITSUBISHI ELECTRIC - logol

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals