GOODWE GW3648D-ES Hybrid Inverter Installation Guide
- June 15, 2024
- GOODWE
Table of Contents
Quick Installation Guide
Hybrid Inverter
ES Series
(GW3648D-ES | GW5048D-ES | GW5048C-ES | GW3648C-ES)
V1.2-2022-12-30
01 Safety Precautions
General Disclaimer
- The information in this quick installation guide is subject to change due to product updates or other reasons. This guide cannot replace the product labels or the safety precautions in the user manual unless otherwise specified. All descriptions here are for guidance only.
- Before installations, read through the quick installation guide. For additional information, please see the user manual.
- All operations should be performed by trained and knowledgeable technicians who are familiar with local standards and safety regulations.
- Check the deliverables for correct model, complete contents, and intact appearance. Contact the manufacturer if any damage is found or any component is missing.
- Use insulating tools and wear personal protective equipment when operating the equipment to ensure personal safety. Wear anti-static gloves, clothes, and wrist strip when touching electronic components to protect the inverter from damage. The manufacturer shall not be liable for any damage caused by static electricity.
- Strictly follow the installation, operation, and configuration instructions in this guide and user manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not follow the instructions. For more warranty details, please visit https://en.goodwe.com/ warranty.
Safety Disclaimer
Warning
DC Side:
- Ensure the component frames and the bracket system are securely grounded.
- Connect the DC cables using the delivered PV connectors. The manufacturer shall not be liable for equipment damage if other connectors are used.
- Ensure the DC cables are connected tightly, securely, and correctly. Inappropriate wiring may cause poor contacts or high impedances, and damage the inverter.
- Measure the DC cable using the multimeter to avoid reverse polarity connection. Also, the voltage should be under the max DC input voltage. The manufacturer shall not be liable for the damage caused by reverse connection and extremely high voltage.
- To avoid shock hazards, ensure the minimum impedance of the PV string to the ground exceeds R, R=Max. Input Voltage (V)/30mA.
- Keep the battery off, and the inverter disconnects with PV panels and other AC power before connecting the battery and the inverter. The rated voltage of the battery should meet specifications of the inverter.
- The PV modules used with the inverter must have an IEC61730 class A rating.
AC Side:
- The voltage and frequency at the connecting point should meet the on-grid requirements.
- Additional protective devices like circuit breakers or fuses are recommended on the AC side. Specification of the protective device should be at least 1.25 times the Max. Output Current.
- PE cable of the inverter must be connected firmly.
- You are recommended to use copper cables as AC output cables. If you prefer aluminum cables, remember to use copper to aluminum adapter terminals.
Product:
-
Do not apply mechanical load to the terminals, otherwise the terminals can be damaged.
-
All labels and warning marks should be visible after the installation. Do not scrawl, damage, or cover any label on the device.
-
Do not touch the running equipment to avoid being hurt as its temperature may exceed 60°C. Do not install the equipment at a place within children’s reach.
-
Unauthorized dismantling or modification may damage the equipment, the damage is not covered under the warranty.
-
Do not start the BACK-UP function if the inverter is not connected to the battery.
-
If there is any radio or wireless communication equipment below 30MHz near the inverter, you have to:
• Install the inverter at least 30m far away from the wireless equipment.
• Add a low pass EMI filter or a multi winding ferrite core to the DC input cable or AC output cable of the inverter. -
Warning labels on the inverter are as follows.
| HIGH VOLTAGE HAZARD. Disconnect all incoming power and turn off the product
before working on it.| | Delayed discharge. Wait 5 minutes after power off
until the components are completely discharged.
---|---|---|---
| Read through the guide before working on this device. | | Potential risks
exist. Wear proper PPE before any operations.
| High-temperature hazard. Do not touch the product under operation to avoid
being burnt.| | Grounding point. Indicates the position for connecting the PE
cable.
| CE marking| | Do not dispose of the inverter as household waste. Discard the
product in compliance with local laws and regulations, or send it back to the
manufacturer.
Check before Power-on
No.|
Check Item
---|---
1
| The product is firmly installed at a clean place that is well-ventilated and easy-to-operate.
2
| The PE, DC input, AC output, and communication cables are connected correctly and securely.
3
| Cable ties are intact, routed properly and evenly.
4
| Unused ports and terminals are sealed.
5
| The voltage and frequency at the connection point meet the inverter grid connection requirements.
EU Declaration of Conformity
GoodWe Technologies Co., Ltd. hereby declares that the inverter with wireless communication modules sold in the European market meets the requirements of the following directives:
- Radio Equipment Directive 2014/53/EU (RED)
- Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS)
- Waste Electrical and Electronic Equipment 2012/19/EU
- Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH)
GoodWe Technologies Co., Ltd. hereby declares that the inverter without wireless communication modules sold in the European market meets the requirements of the following directives:
- Electromagnetic compatibility Directive 2014/30/EU (EMC)
- Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD)
- Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS)
- Waste Electrical and Electronic Equipment 2012/19/EU
- Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH)
You can download the EU Declaration of Conformity on https://en.goodwe.com.
LED Indicators
Indicator
| Status|
Explanation
---|---|---
SYSTEM
| | ON = The system is ready.
| BLINK = The system is starting.
| OFF = The system is not working.
BACK-UP
| | ON = Back-up is ready / power available.
| OFF = Back-up is off / power not available.
SOLAR
| | ON = Solar inputs #1 and #2 are active.
| BLINK 1 = Solar input #1 is active /#2 is not active.
| BLINK 2 = Solar input #2 is active /#1 is not active.
| OFF = Solar input #1 and #2 are not active.
BATTERY
| | ON = The battery is charging.
| BLINK 1 = The battery is discharging.
| BLINK 2 = The battery is low / soc is low.
| OFF = The battery is disconnected/not active.
GRID
| | ON = The grid is active and connected.
| BLINK = The grid is active but not connected.
| OFF = The grid is not active.
ENERGY
| | ON = Consuming energy from grid / buying.
| BLINK 1 = Supplying energy to grid / zeroing.
| BLINK 2 = Supplying energy to grid / selling.
| OFF = The grid is not connected or the system is not working.
WiFi
| | ON = WiFi connected / active.
| BLINK 1 = WiFi is resetting.
| BLINK 2 = WiFi is not connected to the router.
| BLINK 4 = WiFi server problem.
| OFF = WiFi is not active.
FAULT
| | ON = A fault has occured.
| BLINK 1 = Back-up output overload / reduce load.
| OFF = No fault.
Introduction
02 Product Introduction
Parts
- Battery Terminal (BATTERY +/-)
- PV Input Terminal (PV1/PV2)
- DC Switch (optional)
- DC Switch Locking Hole[1]
- Communication Module Port (WiFi or LAN)
- METER Communication Port
- DRED or Remote Shutdown Communication Port
- BMS Communication Port
- RS485 Communication Port
- Reserved Port
- AC Terminal (ON-GRID and BACKUP)
- Indicators
- Mounting Plate
- Heat Sink
- PE Terminal
[1] For Australia only.
Dimensions
03 Inverter Installation
| | | |
---|---|---|---|---
x 1| x 1| x 1| x 1| x 6
| | | |
x 2| x 1| x 1| x 1| x 2
| | | |
x 1| x N| x 2| x 1| x 1
N = Quantity depends on the inverter model.
Space Requirements
Children No Touch
Angle Requirements
Installing the Inverter
(4) For Australia only.
04 Electrical Connection
PE Cable
AC Cable (ON-GRID &BACK-UP)
DC Cable (PV)
MC4
Vaconn
Battery Cable (BATTERY)
05 Communication Connection
DRED Communication Cable
• DRED: Australia and New Zealand.
Remote Shutdown Communication Cable
BMS or Smart Meter
- To Battery
- Battery
- Reserved
- To Smart Meter
- Smart Meter
No. | Color | BMS | Smart Meter | RS485 (EMS) |
---|---|---|---|---|
1 | Orange & White | 485_A2 | NC | 485_A |
2 | Orange | NC | NC | 485_B |
3 | Green & White | 485_B2 | 485_B1 | 485_A |
4 | Blue | CAN_H | NC | NC |
5 | Blue & White | CAN_L | NC | NC |
6 | Green | NC | 485_A1 | 485_B |
7 | Brown & White | NC | 485_B1 | NC |
8 | Brown | NC | 485_A1 | NC |
Communication Module
WiFi Kit, Bluetooth, Wi-Fi/LAN Kit module: optional
06 Power On and Off
Recommended Circuit Breaker
Model | GW3648D-ES GW3648C-ES | GW5048D-ES GW5048C-ES |
---|---|---|
(1) | 125A/60V DC Isolator | |
(2) | 25A/230V AC Breaker | 32A/230V AC Breaker |
(3) | 16A/230V AC Breaker | 20A/230V AC Breaker |
(4) | Depends on loads |
(5)
(6) (optional)| 30A/600V DC Isolator
Power On
Turn on (5)→(3)→(1)→(6)→(4)→(2)
Power Off
Turn off (3)→(5)→(4)→(2)→(1)→(6)
- Battery
- PV
- To Battery
- BACK-UP Loads
- To Smart Meter
- Loads
- CT
- Power Meter
- Grid
07 Commissioning and Monitoring
Commissioning via SolarGo APP
⇓
⇓
Monitoring via SEMS Portal App
⇓
⇓
For more detailed instructions, scan the QR codes below.