legrand ENP2050-NA WiFi Compatible Electrical Box Installation Guide

June 15, 2024
Legrand

Plastic Enclosure
Installation Instructions

Catalog Number(s)
Country of Origin: Made in USA

ENP2050-NA 20” (50.8cm)| 20″ / 30″ / 42” Plastic Enclosure with Hinged Door and Trim Ring
---|---
ENP2060-NA 20” (50.8cm)| 20″ / 30″ / 42” Plastic Door and Trim Ring, Only
ENP2080-NA 20” (50.8cm)| 20″ / 30″ / 42” Plastic Enclosure, Only

INSTALLATION INSTRUCTIONS – Please read these instructions completely before you begin.

IMPORTANT SAFETY INSTRUCTIONS

  1. Do not use this product near water; such as a bath tub, wash bowl, kitchen sink, laundry tub, swimming pool, or in a wet basement.
  2. Never push objects of any kind into this product through openings, as they may touch dangerous voltages. Never touch uninsulated telephone wires or terminals, unless the telephone line has been disconnected at the network interface.
  3. Never install communications wiring, or components, during a lightning storm.
  4.  Equipment shall be installed in accordance with ANSI/NFPA 70, National Electrical Code (NEC), NFPA 72, CAN-ULC-S540, Canadian Electrical Code, and/or other applicable sections of ANSI/IEEE C2 & National Electrical Safety Code (NESC). Equipment intended for installation in information technology equipment (computer) rooms should be installed in accordance with NFPA 75, Standard for the Fire Protection of Information Technology Equipment. NOTE: The enclosure is not fire rated and should not be mounted in fire rated walls.
  5. Power supplied to fire or burglary components must be provided by UL Listed Class 2 fire / burglary power limited power supply.
  6. All power limited and non-power limited wiring must be separated by a minimum of ¼” spacing.
  7. Installation shall be completed by a professional electrical contractor or low voltage technician.
  8. Maximum load carrying capacity of 30 lb.
    ** These enclosures are only compatible with subassembly components as described in the individual subassembly’s installation instructions.

Tools Required

legrand ENP2050-NA WiFi Compatible Electrical Box -
Tools

  1. Enclosure Physical Installation
    Locate enclosure indoors in a low humidity, climate controlled (0°C / 32°F – 49°C / 120°F) area. Remove cable and receptacle knockouts as needed. When required, 2″ rubber grommets (AC1034) are available for the top facing 2″ cable knockouts. Surface Mounting
    Mount to a plywood backboard using the pre-drilled mounting holes on the rear of the enclosure. The use of a level is recommended for correct installation of the enclosure. Recessed Mounting
    Use provided mounting tabs on the sides of the enclosure to secure to wall studs. The use of a level is recommended for correct installation of the enclosure.

  2. Running Power to the Enclosure
    Install a single-gang metal outlet box. Connect 15 amp, 120 volt power receptacle to power cable with approved wiring method to local codes. NOTE: Legrand offers both non-surge protected (F7526) and surge protected (364569-02-V1) outlet kits.![legrand ENP2050-NA WiFi Compatible Electrical Box

  • Fig4](https://manuals.plus/wp-content/uploads/2023/12/legrand-ENP2050-NA- WiFi-Compatible-Electrical-Box-Fig4.jpg)

    1. Trim Ring Assembly
      Align the edges of two trim pieces and push them together until you hear a “CLICK”, indicating the locking tab has engaged.Fit remaining pieces together to complete assembly.legrand ENP2050-NA WiFi Compatible Electrical Box -
Assembly

    2. Affix Trim Ring to Enclosure or Wall
      Using the included screws, affix the Trim Ring to the corresponding holes located in the enclosure frame (4a). If desired, the Trim Ring can be affixed directly to wall studs (4b).legrand ENP2050-NA WiFi Compatible Electrical
Box - Assembly1

    3. Attach Door to Trim Ring
      Starting with the top hinge location, align the door hinge to the trim ring and push until you hear a “CLICK” indicating the hinge is connected. Fit remaining door and trim hinges together to complete installation.legrand
ENP2050-NA WiFi Compatible Electrical Box - Assembly2

    4. Locking the Door
      The enclosure door can lock to the trim ring by applying the provided Phillips head screws to the holes located on the top and bottom corners of the door. A keyed lock is optional (364478-01).

ENP2001-NA 20” (50.8cm)| ENP3001-NA 30” (76.2cm)| ENP4201-NA 42” (106.68cm)
---|---|---
20″ Replacement Trim Ring Kit| 30″ Replacement Trim Ring Kit| 42″ Replacement Trim Ring Kit

Replacement Trim Kits
In the event a provided Trim Ring becomes lost or damaged, Legrand offers a replacement kit for 20”, 30” and 42” sizes.
Alignment of Trim Ring shown below:

legrand ENP2050-NA WiFi Compatible Electrical Box -
Assembly4

No: 1507319 Rev. E