Technical Specifications

Performance

  • Description: Field adjustable lumen output and CCT provide installation flexibility when replacing traditional HID. Integrated AUX port to add lamp-level sensor control.
  • Wattage Equivalency: 320W/400W/600W Metal Halide
  • Input Wattage: 80W/100W/120W

Lumens (Nominal):

  • 80W: 3000K @ 10,800lm; 4000K @ 11,600lm; 5000K @ 11,200lm
  • 100W: 3000K @ 13,500lm; 4000K @ 14,500lm; 5000K @ 14,000lm
  • 120W: 3000K @ 16,200lm; 4000K @ 17,400lm; 5000K @ 16,800lm

Efficacy:

  • 80W/100W/120W: 3000K @ 135lm/W; 4000K @ 145lm/W; 5000K @ 140lm/W
  • L70 Lifespan: 50,000-Hour LED lifespan based on IES LM-70 results

Electrical

  • THD: ≤20%
  • Power Factor: ≥0.9
  • Dimmable: Yes via the Lightcloud Blue mobile app and devices. This lamp will not operate properly when connected to a standard (incandescent) dimmer or dimming control.
  • Input Voltage: 100-277V
  • Operating Frequency: 50/60Hz
  • Input Current @ 120V (mA): 1,031mA
  • Input Current @ 208V (mA): 613mA
  • Input Current @ 240V (mA): 543mA
  • Input Current @ 277V (mA): 433mA
  • Operating Temperature: -22°F to 140°F (-30°C to 60°C)
  • Flicker: <30%
  • Surge Protection: 4kV

LED Characteristics

  • Color Temperature: Field adjustable via dip switch 3000K/4000K/5000K
  • Color Accuracy (CRI): ≥80 CRI
  • R9 Value: High color performance with R9 no less than 0
  • Color Consistency: <6-step MacAdam Ellipse binning to achieve consistent fixture-to-fixture color
  • Color Stability: LED color temperature is warrantied to shift no more than 200K in color temperature over 5 years

Color Uniformity:

  • RAB’s range of Correlated Color Temperature follows the guidelines of the American National Standard for Specifications for the Chromaticity of Solid State Lighting (SSL) Products, ANSI C78.377-2017.

Installation

  • Installation Method: UL Type B, Ballast Bypass
  • Installation Orientation: Vertical

Construction

  • Base Type: EX39
  • Finish: Clear
  • Bulb Shape: Post top (sensor)
  • Endcap Material: Metal
  • Enclosure Material: Polycarbonate

Compliance

  • Listings: UL Listed, UL Classified
  • Environment: Suitable for use in dry and damp environments
  • Fixture Rating: Suitable for use in enclosed fixtures
  • IP Rating: IP64

Model Number for Certification:

  • H20042(HIDFA-120S-EX39-8CCT-BYP/5SP)
  • California Energy Commission (CEC) Status: Lawful for Sales in California

RoHS:

  • Mercury and UV free. RoHS-compliant components.

FCC

  • Complies with Part 15B of the FCC Rules

DLC Listed

  • This product is on the Design Lights Consortium (DLC) Qualified Products List and is eligible for rebates from DLC Member Utilities. Designed to meet DLC 5.1 requirements.
  • DLC Product Code: PZW8AHTW

Other

Compatible Products

  • Add the Lightcloud Blue 5-Pin Plug-in Controller with an optional sensor to connect to the Lightcloud
  • Blue Bluetooth Mesh Wireless Network Lighting
  • Control System. Learn more about Lightcloud Blue.

Accessories

  • CONTROL/W/AUX/5SP/LCB
  • Lightcloud Blue 5-Pin Plug-in Controller
  • CONTROL/W/AUX/5SP/LCBS
  • Lightcloud Blue 5-Pin Plug-in Controller with PIR
  • Sensor
  • CONTROL/W/AUX/5SP/LCBS/MVS
  • Lightcloud Blue 5-Pin Plug-in Controller with MVS Sensor

Warranty

  • RAB warrants that our LED products will be free from defects in materials and workmanship for five (5) years from the date of delivery to the end user, including coverage of light output, color stability, driver performance, and fixture finish.
  • RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.

Note:

  • All values are typical (tolerance +/- 10%)

Buy American Act Compliance:

  • RAB values USA manufacturing! Upon request, RAB may be able to manufacture this product to be compliant with the Buy American Act (BAA). Please contact customer service to request a quote for the product to be made BAA compliant.

Case and Pallet Dimensions

  QTY LENGTH (in) WIDTH (in) HEIGHT (in)
CASE 6 17.32 13.38 12
PALLET 7 48 40 47.34

Dimension

Features

  • Replaces traditional metal halide or high-pressure sodium HID lamp.
  • Adjustable wattage and CCT allow for in-field customization.
  • The integral driver enables the lamp to be wired directly to line voltage without the need for an external driver or ballast.
  • Rated for use in enclosed fixtures in dry or damp locations.
Ordering Matrix
  • Need help? Tech help line: 888-722-1000 Email: sales@rablighting.com
  • Website: www.rablighting.com
  • Copyright © 2023 RAB Lighting All Rights Reserved
  • Note: Specifications are subject to change at any time without notice
  • Project: ————————-
  • Type: —————————
  • Prepared By: ——————
  • Date: —————————

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals