Even heat distribution
Boards with built in foil diffuser layer for quick and easy installation that
provides even heat distribuion across the entire floor.
Lower floor heights
Identical installation method and finished floor heights for all floor
finishes.
For timber suspended & battened floors
Perfect for installation in refurbishment projects and retrofits – where
services or other obstructions are already within the floor void.
Fluted grooves on all panel edges
‘’Fluted’ exit on panel edges to ensure an easy transition into the
neighbouring panel – for a quicker and simpler installation.
Overview
VLo Econna-12 is designed for use over both battened and joisted floors
leaving the void between them free for other services. The profiled 22mm thick
chipboard panels can be installed over battens or joists with spacings of up
to 600mm centres.
The Econna-12 system is ideal for new and old floors alike but when planning
to refurbish an existing floor it can be difficult to know what you will find
without lifting the floor up first. The Econna-12 system is simply installed
over the unknown in place of a standard floor deck rather than competing for
space with the other services within the void beneath.
Typical Floor Build-Up
All floor finishes
-
Floor finish
-
6 mm minimum plywood deck This layer must be screwed to complete the structural deck
-
Floor sensor
Must be recessed into the Econna panel and taped in position. -
Econna panels
Panels secured together using a D4 adhesive on BOTH sides of the tongue and groove and fit together.
Panels then glued and screwed to the joists. -
Warmup 12 mm PE-RT pipe
-
Joists ≤ 600 mm centres Refer to tiling standards for maximum joist centres for floors to receive tiles
-
Insulation layer
Thickness in line with building regulations -
Flow and return pipes *
Installed beneath the Econna panels, notched or through holes drilled in the joists in line with building regulations.
- Service pipes must be insulated within the joist space and supported at 300 mm intervals on horizontal runs and 500 mm on vertical runs using pipe clips
Technical Specifications
Product Code | EC-PANEL |
---|---|
Dimensions | 2400 mm x 600 mm |
Thickness | 22 mm |
Composition | Routed P5 grade chipboard with aluminium heat |
diffuser foil layer
Installation height| 22mm (+ 6 mm plywood layer)
Pipe centres| 150 mm
Weight with water and 6mm ply| Approx. 14 kg/m²
Thermal conductivity| 0.12 W/mK
Soft body impact| BS EN 12871 = Pass
Point load| BS EN 12871, joists at 600mm centres
Ultimate Load, Fmax (kN) = 7.01
Deflection at Fmax (mm) = 28.25
Floor Stiffness, R (Nmm -1 ) = 407.40
Deformation at 0.4 Fmax, Wm (mm) = 7.99
System performance
kH Value – W/m²K
Resistance of Floor
Covering, tog| 0| 0.25| 0.5| 0.75| 1| 1.25| 1.5| 1.75| 2| 2.25| 2.5| 2.75| 3
150mm Pipe Centres| 3.41| 3.11| 2.86| 2.64| 2.46| 2.3| 2.16| 2.04| 1.93| 1.83|
1.74| 1.66| 1.58
q = Specific Heat Output, W/m²| kH = System Performance Factor, W/m²K
---|---
Twater = Mean water Temperature| Tair = Room Air Temperature
Using the system kH value to calculate the system heat output:
q = kH x ( Twater – Tair )
Example:
The heat output through an 18 mm thick, ≈ 1.25 tog timber floor, over Econna
with 6 mm ply, fitted with pipe at 150 mm centres, in a 21°C room heated with
40°C water is;
q = 2.30 x (40 – 21) = 2.30 x 19 = 43.7 W/m²
Alternatively, using the system kH value to calculate the required water
temperature, knowing the required heat output:
Twater
= ( q / kH ) + Tair
Example:
The water temperature required to produce a heat output of 55W/m², through a 3
mm thick ≈ 0.25 tog LVT floor finish, over Econna panels with 6 mm ply, fitted
with pipe at 150 mm centres, in a 22°C room is;
Twater = (55 / 3.11) + 22 = 18.5 + 22 ≈ 40.5°C
Components
| PE-RT Pipe – PERT-12 x XX
Warmup PE-RT (Polyethylene of Raised Temperature Resistance) pipe. The pipe
guarantees leak free performance with a smooth internal structure for improved
flow, reduced pressure loss and deposit formation.
---|---
| Warmup 6iE – 6iE-01-OB-DC / 6iE-01-BP-LC
The world’s first UFH thermostat with a smartphone touchscreen providing
effortless control at your fingertips. Connected to the internet by WiFi, it
can be controlled from
a smart phone, tablet or computer as well as its own touchscreen interface.
Working automatically; it learns your routines and location through background
communication
with your smartphone. Using this knowledge it suggests ways to save energy.
| Warmup Element – RSW-01-WH-RG (ELM-01-WH-RG) / RSW-01-OB-DC (ELM-01-OB-DC)
Warmup’s Element WiFi Thermostat has been designed with simplicity and stylish
functionality in mind. It brings energy-efficient heating control to all
Warmup floor heaters. Combining smart technology with simple, contemporary
design, the Element WiFi Thermostat is the perfect all-rounder to control
Warmup heating systems.
| Pipe bend supports – WHS-P-BEND12
The bend support is used for supporting pipes to make a smooth 90-degree turn
where needed & provides a rigid bend which changes the pipes direction without
causing
excessive bending
| Pipe clips – UK-WUK-HY-ACC-PIPECLIPS12
The robust pipe clips feature a press in to secure and press in to release
design making mounting of the pipe easy. They link together to form a single
rail and secure pipes at
25mm centres, neatly aligning them to the manifold ports.
Contact
Warmup plc
www.warmup.co.uk
uk@warmup.com
T: 0345 345 2288
F: 0345 345 2299
Warmup plc n 704 Tudor Estate n Abbey Road n London n NW10 7UW n UK
Warmup – TS – Econna-12 – V1.2 2023-04-19_EN
Documents / Resources
|
Warmup VLo Econna-12 Joisted Floor
System
[pdf] Instruction Manual
VLo Econna-12 Joisted Floor System, VLo Econna-12, Joisted Floor System, Floor
System, System
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>