ELKAY 2AC8RNFC3 LZ Series Bottle Filling Stations and Coolers Instruction Manual

June 15, 2024
ELKAY

ELKAY 2AC8RNFC3 LZ Series Bottle Filling Stations and Coolers

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-Coolers-
product

Product Information

  • Product Name: LZSTL8WSSP-W1
  • Product Type: Bottle Filling Stations & Coolers
  • Model : LZ TM Series
  • Connected Ready : Yes

Specifications

Versatile cooler design allows units to be installed either left-hand high and right-hand low or left-low and right high. Basin change may be required. See desired rough-in to help determine if the basin change is necessary. Important: The refrigerated coolers must be hung on the right side.

Enhanced

INSTALLATION & USE MANUAL

LZ ™ Series Bottle Filling Stations & Coolers CONNECTED READY

  • Versatile cooler design allows units to be installed either left-hand high and right-hand low or left-low and right high.
  • Basin change may be required. See desired rough-in to help determine if the basin change is necessary. Important: The refrigerated coolers must be hung on the right side.

STANDARD ROUGH-IN FOR LEFT-HAND HIGH, BOTTLE FILLER LOW MODELS

BOSQUEJO ESTÁNDAR PARA MODELOS CON LA LLENADORA DE BOTELLAS BAJA Y LA PARTE IZQUIERDA ALTA DISPOSITION DE CANALISATIONS STANDARD, POUR INSTALLATION GAUCHE HAUTE ET REMPLISSEUSE DE BOUTEILLE BASSE

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-01

EGEND/LEYENDA/LÉGENDE 4 = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) | MAXIMUM OUT FROM WALL UBICACIÓN RECOMENDADA DEL SUMINISTRO DE AGUA. TUBERIA DE COBRE SIN REVES TIMIENTO DE 36 DE DIÁM. EXT. ADAPTADOR DE NO NE A T A S TO DE I EXT. RACCORDER A LA CONDUITE D’ALIMENTATION AVEC UN ROBINET D’ARRÊT (NON FOURNI) À 76 mm (3 PO) MAXIMUM DU MUR 3 = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2 O.D. DRAIN STUB 2 IN. OUT FROM WALL (2 PO) HORS DU MUR C = 1-1/2″ TRAP NOT FURNISHED NO SE INCLUYE SIFON DE 1-1/2′ SIPHON DE 1-1/2 PO NON FOURNI

ALTERNATE ROUGH-IN FOR RIGHT-HAND HIGH, BOTTLE FILLER LOW MODELS – REQUIRES BASIN ASSY CHANGE
BOSQUEJO ALTERNATIVO PARA MODELOS CON LA LLENADORA DE BOTELLAS BAJA Y LA PARTE DERECHA ALTA: REQUIERE CAMBIAR EL CONJUNTO DE TARJA AUTRE DISPOSITION DE CANALISATIONS, POUR INSTALLATION DROITE HAUTE ET REMPLISSEUSE DE BOUTEILLE BASSE – MODIFICATION DE LA FONTAINE REQUISE

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-02

ALTERNATE ROUGH-IN FOR LEFT-HAND LOW, BOTTLE FILLER HIGH MODELS
BOSQUEJO ALTERNATIVO PARA MODELOS CON LA LLENADORA DE BOTELLAS ALTA Y LA PARTE IZQUIERDA BAJA AUTRE DISPOSITION DE CANALISATIONS, POUR INSTALLATION GAUCHE BASSE ET REMPLISSEUSE DE BOUTEILLE HAUTE

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-03

ALTERNATE ROUGH-IN FOR RIGHT-HAND LOW, BOTTLE FILLER HIGH MODELS – REQUIRES BASIN ASSY CHANGE
BOSQUEJO ALTERNATIVO PARA MODELOS CON LA LLENADORA DE BOTELLAS ALTA Y LA PARTE DERECHA BAJA: REQUIERE CAMBIAR EL CONJUNTO DE TARJA AUTRE DISPOSITION DE CANALISATIONS, POUR INSTALLATION DROITE BASSE ET REMPLISSEUSE DE BOUTEILLE HAUTE – MODIFICATION DE LA FONTAINE REQUISE

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-04 NOTE

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-05

  1. Ensure that there are no plumbing or external objects below the wrapper in the specified dimension. This minimum distance is required for
    the wrapper to swing out.

  2. To access internal components, remove security screw and gently move wrapper down and rotate. When servicing is completed and once wrapper is in place prior to engaging security screw with frame threads, ensure thru hole is aligned with frame threads. Ensure screw is angled relative to the ground and perpendicular to wrapper surface prior to engagement. Hand tighten prior to using hand tool to avoid cross-threading. DO NOT USE POWER TOOL TO TIGHTEN. DO NOT OVERTIGHTEN.

  3. Removing the wrapper from the pivoting bracket when servicing the unit is recommended. The wrapper may be left in place for quick serviceability.

  4. CAUTION : DO NOT LEAN ON WRAPPER.

  5. CAUTION : WRAPPER DROPS AND SWINGS WHEN SECURITY SCREWS ARE REMOVED.

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-06

NOTE
The highlighted portion in red color is acceptable plumbing rough-in for installation.

NOTE
To mitigate the wrapper rotation interferences, zip tie lines (plumbing and electrical) running between the cooler units to the waste line (PVC pipe).

HANGER BRACKETS INSTALLATION

  1. Remove hanger bracket fastened to back of coolers by removing one (1) screw.

  2. Determine your mounting configuration from the figures shown on pages 2 – 5. Refrigeration unit must be on right hand side. IMPORTANT NOTE: If the Bottle Filler is to be mounted on the left hand cooler, a basin assembly change will be needed.
    Determine your configuration by referring to the Configuration Instructions on page 9 prior to continuing.

  3. Mount the hanger bracket as shown in Figures 1 – 4 (Pages 2 – 5).
    NOTE : Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mountin holes.
    IMPORTANT : 5-7/8 in. (150 mm) dimension from wall to centerline of trap must be maintained for proper fit. INSTALLATION OF COOLER

  4. Remove the two front screws holding the lower front panel to the cooler frame (see Fig 5, Pg. 7). Rotate the front panel down (see Fig D, Pg. 6) and remove.

  5. Hang only the refrigerated cooler on the hanger bracket. Be certain hanger bracket is properly in the slots on the cooler backs as shown in Figures 1 (Pg. 2), 2 (Pg.3), 3 (Pg. 4), and (Fig. 4, Pg. 5).

  6. Hang the non-refrigerated cooler on the hanger bracket. Be certain hanger bracket is engaged properly in the slots on the cooler backs as shown in Figures 1, (Pg. 2), 2 (Pg. 3), 3 (Pg. 4), and 4 (Pg. 5).

  7. Unbend the loose wires in the refrigerated cooler for the NFC board. Stretch it out and thread through the left side of the refrigerated cooler and into the right side of the non-refrigerated cooler. Plug into the NFC board that is behind the filter head.

  8. Secure each cooler frame to wall by installing (2) screws and washers (not supplied). See pictures below. Make sure the screws engage in a structural member.
    ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-08

  9. Connect the supply water to the filter 3/8” copper inlet tube.

  10. Connect the waterline from the outlet of the filter to the inlet of the evaporator in the refrigerated cooler by inserting it into the quick connector.

  11. Connect the waterline from the solenoid in the non-refrigerated cooler to the open 1/4” inch tee fitting in the refrigerated cooler.

  12. Find your cooler configuration on page 11 and connect the drain assembly together.

  13. Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap. Assemble the slip nut and gasket to the trap and tighten securely.
    IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.
    BOTTLE FILLER INSTALLATION

  14. Remove two (2) mounting screws with 5/32” Allen wrench holding Bottle Filler to wall mounting plate (See Fig. 8). Note do not discard mounting screws, they will be needed to secure Bottle Filler to wall mounting plate.

  15.  Remove wall mounting plate from Bottle Filler (See Fig. 8 ). Place wall mounting plate against wall on top of basin. Center the wall mounting plate side to side with the basin. Mark the six (6) mounting holes with a pencil (See Fig. 1, Pg. Place tape over wiring harness connection on top of cooler to prevent debris from falling into Connection(See Fig. 6, Pg. 7).

  16. Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add fixture support carrier if wall will not provide adequate support.

  17. Install wall mounting plate to wall using six (6) 7/16” obround mounting holes (mounting
    bolts not included) (See Fig. 7, Pg. 7). Use appropriate fasteners for your wall type.

  18.  Install gasket on bottom of Bottle Filler with gasket support bracket & (2) screws. (See Fig. 8).

  19. Route 3/8” tubing through the opening in the bottle filler gasket and plug into bulkhead fitting in basin. Route the wiring harness through the gasket and plug into the connector on the top of the basin.

  20.  Place Bottle Filler on the four (4) hooks on the mounting plate installed on wall.
    ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-010ELKAY-2AC8RNFC3-LZ-
Series-Bottle Filling-Stations-and-Coolers-011 FINAL INSTALLATION (FILTER)

  21. Remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise. Ensure that filter label can be read when filter is installed. (See Fig. 12)

  22. Turn water supply on and inspect for leaks. In both cooler and Bottle Filler. Fix all leaks before continuing.

  23.  Once cooler and bottle filter have been inspected for leaks and any leaks corrected, plug cooler into wall.

  24. Reinstall two mounting screws from first step above. Caution do not over tighten screws.

  25. Once power is applied to the cooler the GREEN LED light will illuminate on the bottle filler showing good filter status along with the LCD Bottle Counter.

  26. Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify that the water dispenses. Note: the first initial dispenses might have air in line which may cause a sputter. This will be eliminated when all air is purged from the line.

  27. Once unit tests out, install Lower Panels back on water coolers. (See pages 12-13 for versatile wrapper installation). Units are now ready for use.

INSTRUCTIONS FOR REPLACING FILTERS

  1. Remove the two front screws holding the lower front panel to the cooler frame (see Fig 5, Pg. 7). Rotate the front panel down (see Fig D, Pg. 6) and remove.
  2. Turn off water supply; dispense water to relieve pressure.
  3. Remove power by unplugging cooler.
  4. Turn used filter counterclockwise 1/4 turn to remove from filter head.
  5. Remove cap from new filter and use to seal used filter.
  6. Insert new filter into existing filter head and turn fully clockwise. Make sure you can read the label on the front of the filter once it is installed.(See Fig. 22 on Pg.15).
  7. Plug in unit to restore power.
  8. Turn on water supply and run a minimum of two gallons of water through the filter to purge air any fine carbon particles from filter. Also run water through bottle filler.
    Note : Filter status light will automatically reset once new filter is installed.

INSTRUCTIONS TO ACCESS PROGRAMMING BUTTON

  1. Remove lower cover on refrigerated unit by removing (2) screws.
  2.  Button is located in lower right corner of unit (See Fig. 13).
    ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-013

CONFIGURATION INSTRUCTIONS

INSTRUCTIONS TO MOVE THE BOTTLE FILLER & BASIN TO THE LEFT SIDE (NON- REFRIGERATED) FOR ALTERNATE MOUNTING VERSATILE BI-LEVEL

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-014 ELKAY-2AC8RNFC3-LZ-
Series-Bottle Filling-Stations-and-Coolers-015

ONLY move the filler panel and j-clip to the refrigerated (right) side if right side will be mounted “high”

  1. Remove the two front screws holding the lower front panel to the cooler frame (see Fig 5, Pg. 7). Rotate the front panel down (see Fig D, Pg.6 ) and remove.

  2. Remove filler panel from cooler using a 5/16” socket.

  3. Using a T25 (6-point star) bit, loosen the shroud screws on both sides of both coolers.

  4. Lift the basin/shroud assembly from each cooler. Disconnect the water line from the solenoid and the shroud wires from the wiring harness and solenoid. Set aside.

  5. Unfasten the electrical harness connector from the electrical bracket. Using a T25 (6-point star) bit, remove the electrical bracket from the mounting bracket. Snap the electrical harness connector into the cutout of the mounting bracket with the connector facing down. (See Fig 14.)

  6. Install the electrical bracket on the filter bracket of the non-refrigerated cooler by removing the two screws towards the front of the cooler and reinstalling them through the bracket. Attach the female end of the bi-level extension into the electrical bracket.

  7. Only move the filler panel and J-clip to the refrigerated (right) cooler if the right side will be mounted high.

  8. Install the non-bottle filler basin on the refrigerated cooler. Connect the water line to the solenoid and the electrical connections to the wiring harness and solenoid. Tighten the (4) T25 screws.

  9. Mount the refrigerated cooler on the right-hand hanger bracket. Secure to wall.

  10. Install the bottle filler basin on the non-refrigerated cooler. Connect the water line to the solenoid and the electrical connections to the wiring harness and solenoid. Be certain the electrical connector is protruding through the cutout in the top of the basin. Tighten the (4) T25 screws.

  11.  Mount the non-refrigerated cooler on the left-hand hanger bracket. Secure to wall.

  12. Route the bi-level extension through the coolers and connect to the refrigerated electrical harness mounted in the mounting bracket (See Figs. 15 & 16).

  13. Hook up the drains using the attached drain kit.

  14. Make all water and electrical connections.

  15. Reinstall wrappers using (2) screws for each wrapper.

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-017

LZSTL8WSSP-W1

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-018 ELKAY-2AC8RNFC3-LZ-
Series-Bottle Filling-Stations-and-Coolers-019

Swap drain parts in shroud: Loosen each hose clamp retaining the drain pieces. Remove each drain piece and swap to other basin.

Tighten each hose clamp.

Enhanced EZH2O Error Codes

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-028PLUMBING DIAGRAMS VERSATILE BI-LEVEL

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-020

Versatile Wrapper and Trim Kit Installation Instructions

Left Hand Wrapper (High Side)

  1. Remove the (2) screws from the wrapper, rotate the wrapper down, and remove.
  2. Screw trim piece to wrapper with (2) screws (provided).
  3. Re-install wrapper with (2) screws.
  4. Dispose of unused cover plate.
    Right Hand Wrapper (Low Side)

Right Hand Wrapper (Low Side)

  1. Remove the (2) screws from the wrapper, rotate the wrapper down, and remove.
  2.  Clip cover plate, sliding until plate sits flush with the wall.
  3. Re-install wrapper with (2) screws.

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-023115V Refrigerated Wiring Diagram with Alpha/Numeric Display Connected Ready – Enhanced Bottle Filler

ELKAY-2AC8RNFC3-LZ-Series-Bottle Filling-Stations-and-
Coolers-026OPEOPERARATION OF QUICK CTION OF QUICK CONNECT FITTINGSONNECT FITTINGS

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ELKAY User Manuals

Related Manuals