AVCOMM AP316 Series Industrial Cellular Poe Routing Switch Installation Guide
- June 15, 2024
- AVCOMM
Table of Contents
Quick Installation Guide
Industrial Cellular PoE
Routing Switch
AP316
www.avcomm.cn
Overview
The LTE PoE router AP316 provides ultra-resilient network by latest G.8032
ERPS v2 ring technology with 6 Giga ports, 2port 100/1000M fiber ports, and
simultaneous supports highspeed LTE routing. The LTE can backup network in
case of ring failure and works as a redundant gateway. Dual SIM standby
enables auto switch to secondary cellular network if primary network
disconnects. Moreover, the router offers 4 Gigabit PoE/PoE+ ports for feeding
IP cam or wireless AP.
Integrated firewall ensures safe data transmission. Compact size and
ruggedized design bring reliable deployment under the harshest conditions.
Model Name | Description |
---|---|
AP316WLAN-SFP | Industrial Wireless Ring Network IIoT Routing POE |
Gateway,802.11 b/g/n WLAN Cat. 4. 2×2 MIMO,4G/3G/2G, 4-Port Gigabit POE Plus
2-Port Gigabit SFP,ITU standard ring redundancy protocol, under 50ms
protection and recovery switch, dual power 46 to 57VDC, -40°C to 75°C, IP30
AP316-LTESFP| Industrial Wireless Ring Network IIoT Routing POE Gateway,LTE
CAT.4, 2×2 MIMO,4G/3G/2G, 4-Port Gigabit POE Plus 2-Port Gigabit SFP,ITU
Standard Ring Redundancy Protocol, Protection and Recovery Switching below
50ms, Dual Power 46 to 57VDC, To 40 ° C to 75 ° C, IP30
Package Checklist
- 1 x Product Unit (Without SFP transceiver)
- 1 x 6-pin Removable Terminal Connector
- 1 x Attached Din Clip
- 2 x LTE Antenna, Black
- 1 x Quick Installation Guide Optional Accessory (for detailed information please refer to the Datasheet)
- Wall-mounting kit with 2 plates and 8 screws
Installation
SIM Card Slot
The SIM Card Slot is used to insert the cellular card.
Warning: Be careful when install the SIM Card, wrong installation
procedure will cause damage. Make sure that pinhole of tray holder is facing
up.
DIN Rail mount
To mount the router on the DIN Rail track, insert the upper end of the
DIN‐Rail clip into the back of the DIN‐Rail track from its upper side and
lightly push the bottom of the DIN‐Rail clip into the track. The DIN Rail
should comply with DIN EN50022 standard. Using wrong DIN rail may cause
unsafe installation.
Grounding Screw
The grounding screw is located on the bottom sideof the router. For avoiding
system damage by noise or electric shock, establish a direct connection
between the ground screw and the grounding surface prior to connecting
devices.
Wiring the Relay Output
The relay output of the 2-pin terminal block connector are used to detect
user-configured events. The two wires attached to the fault contacts form a
close circuit when a user- configured event is triggered. If a user-
configured event does not occur, the fault circuit remains opened.
Wiring the Power Input
- Insert the positive and negative wires into the V+ and V- contact on the terminal block connector.
- Tighten screws when the wire is connected.
- Connect the power wires to suitable DC Switching type power supply.
USB Port
Use the USB port in order to save or restore the configuration and upload the
firmware upgrade file.
For further configurations, please refer to User Manual.
Appearance
AP 316
LED Indication
LED | Status | Description |
---|---|---|
PWR (1/2) | Green On | DC-IN Power is On |
Off | No Power in DC-IN |
System
LED| Green On| Ready
Green Blinking| Firmware Updating
Off| Not Ready
DO| Red On| Any failures in port link by SW
control
Off| No failure occurs
Fiber Port| Green On| Links established
Green Blinking| Packets transmitting/receiving
Off| Link is inactive
Ring LED| Green On| Ring Normal (Not RPL Owner)
Green Blinking| Ring Normal (RPL Owner)
Amber On| Ring Abnormal
Amber Blinking| Ring Port Fail
Off| Ring is disabled
PoE LED| Green On| PoE delivering in progress
Green Off| PoE is disabled / No Powered
Device
Radio LED
Model Name | LTE Status |
---|---|
Ra | 4G Connection: Green On |
2/3G connection: Green Blinking
Disconnected: Off
Antenna
The device supports up to 2 antennas sockets. AVCOMM provides the optional accessories, where the antenna color is black for the LTE.
| AP316
---|---
Ant 1| LTE-Main
Ant 2| LTE- Aux
Safety Precautions
➢ Turn off DC power input source before connecting the DC Power supply module
to the terminal block connectors. Do not turn-on the source of DC power module
and make sure all connections were well established, then power on the DC
source to powering the device.
➢ Do make sure that models connect to the corresponding supply voltage. The
device is to be supplied by Limited Power Supply.
➢ The router is designed for Industrial IoT, ITS, wayside surveillance
application.
➢ Never install or work on/with the equipment or the cabling during the period
of its lightning activity.
Management
This device supports both in-band and out-of-band network management.
The user can either configure the device through the user-friendly Web/HTTPS
management or remotely manage the device through the network Telnet/SSH.
-
Preparation for Web management: First, verify that device is properly installed in the network and that every PC of this network can access the router through the web browser (Google Chrome, Internet Explorer, Mozilla Firefox).
• Type http://IP_address in your browser (the default IP address is http://192.168.10.1/)
• Key in the username and password in login screen. The default username and password is admin.
• After you click OK, the Welcome page of the web-based management interface will appear.
• On the left side you can see the list of software features, on the right side – available settings.
◆ To link with the device, please make sure that the IP Address of the PC is located in the same subnet (192.168.10.x). -
Preparation for Telnet/SSH management: You can connect to the device by Telnet and the command lines. Below are the steps to open Telnet connection to the router.
• Start -> Open Command prompt ->Enter
• Type the Telnet 192.168.10.1 (or the IP address of the router). And then press Enter.
SSH (Secure Shell)
The device also supports SSH console. You can remotely connect to the router
to access command line interface. The SSH connection can secure all the
configuration commands you sent to the switch.
SSH is a client/server architecture while the Router is the SSH server.
When you want to make SSH connection with the switch, you should download the
SSH client tool first.
SSH Client
There are many free, sharewares, trials or charged SSH clients you can find on
the internet.
◆ For further feature configurations, please refer to User Manual.
Support
At AVCOMM, you can use the online service forms to request the support. The submitted forms are stored in server for AVCOMM team member to assign tasks and monitor the status of your service. Please feel free to write to sales@n-tron.com.cn if you encounter any problems.
Warranty
5-year Global warranties are available for AVCOMM products assuring our customers that the products shall remain free from defects in workmanship or materials and conform in all material respects to AVCOMM specifications, or Purchaser’s supplied and accepted specifications. The warranty is limited to the repair and/or replacement, at AVCOMM’ sole discretion, of the defective product during its warranty period. The customer must obtain a Return Merchandise Authorization (RMA) approval code prior to returning the defective Product to AVCOMM for service. The customer agrees to prepay shipping charges, to use the original shipping container or equivalent, and to ensure the Product or assume the risk of loss or damage in transit. Repaired or replaced products are warranted for ninety (90) days from the date of repair or replacement, or for the remainder of the original product’s warranty period, whichever is longer.
Disclaimer
AVCOMM reserves the right to make changes to this QIG or to the product
hardware at any time without notice. It is the user’s responsibility to
determine whether there have been any such updates or amendments herein.
Defects, malfunctions, or failures of the warranted Product(s) caused by
damage resulting from unforeseeable incidents (such as lightings, floods,
fire, etc.), environmental and atmospheric disturbances, other external forces
such as power line disturbances and surge, host computer malfunction and
virus, incorrect power input, or incorrect cabling, incorrect grounding and
damages caused by misuse, abuse and unauthorized alteration or repair are not
warranted.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>