AVCOMM 6006GX2-POE Industrial 4G + 2GF L2+-L3 PoE Cyber Security Switch
Overview
The new 6006GX2-POE is full Gigabit Managed Switch with Layer 2 functions. Both switches provide more flexibility in planning a large-scale IP network. 6006GX2-POE is equipped with 4-port 10/100/1000Base-T RJ-45 and 2-port 100/1000 Base-X SFP connectivity, where 6006GX2-POE supported 8 x100M 802.3at PoE ports. These switches provide reliable network with high performance. It supports critical cyber security features that meet IEC62443-4-2 criteria. Advanced management and redundancy features guarantee the fastest network recovery, zero packet loss data transmission, and high level of network protection against the hackers’ attacks. Besides, for 6006GX2-POE , it has a rugged design with EN 61850-3/IEEE 1613/EN 50121-4 standard which is the best choice for substation and railway wayside applications.
| 6006GX2- POE
---|---
10/100Base- T| 4
100/1000Base SFP| 2
PoE Mode| IEEE 802.3af/at
Power input
|
46~57VDC (50~57VDC for 802.3at)
Package Checklist
- 1 x Product Unit (Without SFP transceiver)
- 1 x 8-pin Removable Terminal Connector
- 1 x Din Clip
- 1 x Quick Installation Guide
Optional Accessory (for detailed information please refer to the Datasheet):
- 10Gbps SFP+ Transceiver
- 1000Mbps SFP Transceiver
- RS232 Console Cable
- Wall-mounting kit with 2 plates and 8 screws
Installation
DIN Rail mount
To mount the switch on the DIN Rail track, insert the upper end of the
DIN‐Rail clip into the back of the DIN‐Rail track from its upper side and
lightly push the bottom of the DIN‐Rail clip into the track. The DIN Rail
should comply with DIN EN50022 standard. Using wrong DIN rail may cause unsafe
installation.
Grounding Screw
For avoiding system damage by noise or electric shock, establish a direct
connection between the ground screw and the grounding surface prior to
connecting devices.
Wiring the Relay Output
The relay output of the 2-pin terminal block connector are used to detect
user-configured events. The two wires attached to the fault contacts form a
close circuit when a user configured event is triggered. If a user-configured
event does not occur, the fault circuit remains opened.
Wiring the Power Input
- Insert the positive and negative wires into the V+ and V- contact on the terminal block connector.
- Tighten screws when the wire is connected.
- Connect the power wires to suitable DC Switching type power supply.
Wiring the Digital Input
To wire the DI on the Terminal block, loosen screws by screw driver on the
terminal block connector, insert the positive and negative wires into the V+
and V-contact and then tighten screws after the DI wire is connected.
USB Port
Use the USB port in order to save or restore the configuration and upload the
firmware upgrade file. For further configurations, please refer to User
Manual.
Appearance
LED Indication
LED | Status | Description |
---|
PWR
(P1/P2)
| Green On| DC-IN Power is On
Off| No Power in DC-IN
__
System LED
| Green On| Ready
Green Blinking| Firmware Updating
Off| Not Ready
__
__
__
Ring LED
| Green On| Not Owner/Normal
Green Blinking| Owner/Normal
Amber On| Abnormal
Amber Blinking| Ring Port Fail
Off| Ring is disabled
__
Alarm (DO)
| __
Red On
| Any failures in port link, ping,
power, DO and DI State by SW
control
Off| No failure occurs
Digital Input (DI)| Green On| Detected Digital Input
Off| No Digital Input
PoE LED
1~4 (6006GX2- POE)
| Amber On| PoE delivering in progress
Amber Off| PoE is disabled / No Powered Device
__
__
1000M
Ethernet (Port1-4)
| Green On| Links established
Green Blinking| Packets transmitting/receiving
Green Off| Link is inactive
Amber On| Link Speed 1000M
Amber Off| Link speed 100M
LED| Status| Description
---|---|---
SFP Port (Port5~6)
| Green On| Links established
Green Blinking| Packets transmitting/receiving
Green Off| Link is inactive
Amber On| Link Speed 1000M
Amber Off| Link speed 100M
Safety Precautions
- Turn off DC power input source before connecting the DC Power supply module to the terminal block connectors. Do not turn-on the source of DC power module and make sure all connections were well established, then power on the DC source to powering the Switch device.
- Do make sure that models connect to the corresponding supply voltage. The device is to be supplied by Limited Power Supply. The relay contact supports 0.5 A current, DC 24V.
- Do not touch the surface of the switch while it is performing PoE function!
Management
This device supports both in-band and out-of-band network management. The user can either configure the device through the user friendly Web/HTTPS management or remotely manage the device through the network by console management or Telnet/SSH.
- Preparation for Web management: First of all, verify that device is properly installed in the network and that every PC of this network can access the switch through the web browser (Google Chrome, Internet Explorer, Mozilla Firefox).
- Type http://IP_address in your browser (the default IP address is http://192.168.10.1/)
- Key in the user name and password in login screen. The default user name and password is admin.
- After you click OK, the Welcome page of the web-based management interface will appear.
- On the left side you can see the list of software features, on the right side – available settings.
- Preparation for Console management (using RS232 Port):
- Connect console cable between your PC and the device.
- Start -> Program -> Accessories -> Communication -> Hyper Terminal.
- Give a name to a new console connection.
- Choose the COM name and select correct serial settings: Baud Rate: 115200 / Parity: None / Data Bit: 8 / Stop Bit: 1
- After connected, type the username admin and password admin to login.
- Follow the User Manual to configure the software features.
- Preparation for Telnet/SSH management: You can connect to the device by Telnet and the command lines are the same as what you see by console management. Below are the steps to open Telnet connection to the switch.
- Start -> Open Command prompt ->Enter
Type the Telnet 192.168.10.1 (or the IP address of the switch). And then press Enter.
- Start -> Open Command prompt ->Enter
SSH (Secure Shell)
The device also supports SSH console. You can remotely connect to the switch
to access command line interface. The SSH connection can secure all the
configuration commands you sent to the switch.
SSH is a client/server architecture while the Switch is the SSH server. When you want to make SSH connection with the switch, you should download the SSH client tool first.SSH Client
There are many free, sharewares, trials or charged SSH clients you can find on the internet.
- For further feature configurations, please refer to User Manual.
Support
At AVCOMM, you can use the online service forms to request the support. The submitted forms are stored in server for AVCOMM team member to assign tasks and monitor the status of your service. Please feel free to write to sales@avcomm.cn if you encounter any problems.
Warranty
5-year Global warranties are available for AVCOMM products assuring our customers that the products shall remain free from defects in workmanship or materials and conform in all material respects to AVCOMM specifications, or Purchaser’s supplied and accepted specifications. The warranty is limited to the repair and/or replacement, at AVCOMM sole discretion, of the defective product during its warranty period. The customer must obtain a Return Merchandise Authorization (RMA) approval code prior to returning the defective Product to AVCOMM for service. The customer agrees to prepay shipping charges, to use the original shipping container or equivalent, and to insure the Product or assume the risk of loss or damage in transit. Repaired or replaced products are warranted for ninety (90) days from the date of repair or replacement, or for the remainder of the original product’s warranty period, whichever is longer.
Disclaimer
AVCOMM reserves the right to make changes to this QIG or to the product hardware at any time without notice. It is the user’s responsibility to determine whether there have been any such updates or amendments herein.
Defects, malfunctions, or failures of the warranted Product(s) caused by damage resulting from unforeseeable incidents (such as lightings, floods, fire, etc.), environmental and atmospheric disturbances, other external forces such as power line disturbances and surge, host computer malfunction and virus, incorrect power input, or incorrect cabling, incorrect grounding and damages caused by misuse, abuse and unauthorized alteration or repair are not warranted.