AVCOMM 8022GX6 Industrial 16G + 6GF L2+-L3 Managed Ethernet Switch Installation Guide
- June 3, 2024
- AVCOMM
Table of Contents
AVCOMM 8022GX6 Industrial 16G + 6GF L2+-L3 Managed Ethernet Switch
Overview
8022GX6 is designed for industrial environments requiring high security and high-quality Ethernet/Fiber communication, such as industrial automation, road traffic control, etc. The switch provides 22-port full-gigabit Ethernet including 16-port Gigabit RJ45 and 6-port 100M/1G SFP. Full Gigabit capability and rugged industrial design ensures system high performance and reliability in harsh environments. For convenient traffic control and zero packet loss data transmission, the switch offers contemporary management and security functions.
Model Name | Description |
---|---|
8022GX6 | Industrial 22-port Full Gigabit L2+ Managed Ethernet Switch, |
16GT+6GSFP, 24VDC Input
Package Checklist
- 1 x Product Unit (Without SFP Transceiver)
- 2 x 4-pin Removable Terminal Connector
- 1 x Attached Din Clip
- 1 x Quick Installation Guide
Optional Accessory (for detailed information please refer to the Datasheet)
Installation
DIN Rail mount
To mount the switch on the DIN Rail track, insert the upper end of the
DIN‐Rail clip into the back of the DIN‐Rail track from its upper side and
lightly push the bottom of the DIN‐Rail clip into the track. The DIN Rail
should comply with DIN EN50022 standard. Using wrong DIN rail may cause unsafe
installation.
Wiring the Power Inputs
- Insert the positive and negative wires into the V+ and V- contact on the terminal block connector.
- Tighten the wire-clamp screws.
- Connect the power wires to suitable DC Switching type power supply. The input DC voltage should be in the range of 10VDC to 60VDC.
Grounding Screw
For avoiding system damage by noise or electric shock, establish a direct
connection between the ground screw and the grounding surface prior to
connecting devices.
Wiring the Digital Input
To wire the DI on the Terminal block, loosen screws by screwdriver on the
terminal block connector, insert the positive and negative wires into the V+
and V- contact and then tighten screws after the DI wire is connected.
Wiring the Relay Output
The relay output of the 2-pin terminal block connector are used to detect
user-configured events. The two wires attached to the fault contacts form a
close circuit when a user-configured event is triggered. If a user-configured
event does not occur, the fault circuit remains open.
Console/Reset
The switch provide Reset and RS232 console for out of band configuration. The
default baud rate setting is 115,200, N, 8, 1.
Reset button allows you to reset switch or reload to factory default (>7 sec).
For further configurations, please refer to User Manual.
Appearance
LED Indication
LED | Status | Description |
---|---|---|
PWR (P1/P2) | Green On | DC-IN Power is On |
Off | No Power in DC-IN | |
Alarm (DO) | Red On | Any failures in port link, ping, power, DO and |
DI State by SW control
Off| No failure occurs
LED| Status| Description
---|---|---
RJ45 Port| Green On| Links established
Green Blinking| Packets transmitting/receiving
Green Off| Link is inactive
Amber On| Link Speed 1000M
Amber Off| Link Speed 100M
SFP Port| Green On| Links established
Green Blinking| Packets transmitting/receiving
Green Off| Link is inactive
Amber On| Link Speed 1000M
Amber Off| Link Speed 100M
Safety Precautions
- Keep DC power off before connecting to the terminal block connectors and ensure all connections are secure established.
- The switch must be installed at Restricted Access Locations, such as control room/control cabinet. The switch is designed for in building installation only and is not intended to be connected to exposed (outside plant) networks.
- Never install or work on/with the equipment or the cabling during the period of its lightning activity.
- The DIN Rail should comply with DIN EN50022 standard. Using wrong DIN rail may cause unsafe installation.
Management
This device supports both in-band and out-of-band network management. The user can either configure the device through the user-friendly Web/HTTPS management or remotely manage the device through the network by console management or Telnet/SSH.
- Web management: Before start, confirm that device is properly connected in the network and that each PC in this network can access the router through the web browser (Google Chrome, Internet Explorer, Mozilla Firefox).
- Type http://IP_address in the address bar (Default IP address is http://192.168.10.1/)
- Enter the username and password in Login screen and click Login. The default username and password are admin.
- You are required to change your password at first login. the welcome page of the web-based management interface will pop up when password is changed.
- On the left side listed software features, and on the right side are available settings.
- To link with the device, please make sure that the IP Address of the PC is located in the same subnet (192.168.10.x).
- Console management (using RS232 Port):
- Connect console cable between your PC and the device.
- Start -> Program -> Accessories -> Communication -> Hyper Terminal.
- Give a name to a new console connection.
- Choose the COM name and select correct serial settings: Baud Rate: 115200 / Parity: None / Data Bit: 8 / Stop Bit: 1
- After connected, Key in the New user name and password in login screen while first Login. (The default user name and password in elder firmware is admin/admin. Try this while you don’t see New user name/password prompt while first login.)
- Follow the User Manual to configure the software features.
- Telnet/SSH management: The router can be connected by Telnet and the command-lines. Steps to open Telnet connection to the router are as follow:
- Start -> Open Command prompt ->Enter
- Type the Telnet 192.168.10.1 (or the IP address of the switch). And then press Enter.
SSH (Secure Shell)
The router supports SSH console and can be connected via command-line
interface access remotely. SSH connection can secure all the configuration
commands that sent to the switch.
SSH Client
There are many free, sharewares, trials or charged SSH clients you can find on
the internet.
Support
At AVCOMM, you can use the online service forms to request the support. The
submitted forms are stored in server for AVCOMM team member to assign tasks
and monitor the status of your service. Please feel free to write to
sales@avcomm.cn if you encounter any problems.
Warranty
5-year Global warranty are available for AVCOMM products assuring our customers that the products shall remain free from defects in workmanship or materials and conform in all material respects to AVCOMM specifications, or purchasers supplied and accepted specifications. The warranty is limited to the repair and/or replacement, at AVCOMM sole discretion, of the defective product during its warranty period. The customer must obtain a Return Merchandise Authorization (RMA) approval code prior to returning the defective Product to AVCOMM for service. The customer agrees to prepay shipping charges, to use the original shipping package or equivalent, and to ensure the product or assume the risk of loss or damage in transit. repaired or replaced products are warranted for ninety (90) days from the date of repair or replacement, or for the remainder of the original product’s warranty period, whichever is longer.
Disclaimer
AVCOMM reserves the right to make changes to this QIG or to the product hardware at any time without notice. It is the user’s responsibility to determine whether there have been any such updates or amendments herein. Defects, malfunctions, or failures of the warranted Product(s) caused by damage resulting from unforeseeable incidents (such as lightings, floods, fire, etc.), environmental and atmospheric disturbances, other external forces such as power line disturbances and surge, host computer malfunction and virus, incorrect power input, or incorrect cabling, incorrect grounding and damages caused by misuse, abuse and unauthorized alteration or repair are not warranted.