gas clip QSG-GCT XP External Pump User Guide

June 15, 2024
gas clip

gas clip QSG-GCT XP External Pump

Product Information

Specifications

  • Device: GCT External Pump
  • Manufacturer: Gas Clip Technologies
  • Compatible with : Gas Clip Technologies’ diffusion gas detectors (Single Gas Clip, Single Gas Clip Plus, Multi Gas Clip, MGC Simple and MGC Simple Plus)
  • Components: Infrared Communication Window, Audible Alarm, Power LED, Power Button, Charging LED, Flow LED, Alligator Clip, Gas Inlet Port, Pellet Filter, Hydrophobic Filter, Certification Label, Model and Serial Label, Gas Outlet Port, Charging Port
  • Included in the box: GCT External Pump, charger, 3 ft. hose, 10 ft. hose, stainless steel diffusion stone, 10 additional filters (5 hydrophobic & 5 particulate)

Product Usage Instructions

Set Up

  1. Connect the 3 ft. hose from the gas outlet port to a Gas Clip Technologies detector with a calibration cap.
  2. Connect the 10 ft. sampling hose from the gas inlet port to the diffusion stone.
  3. Optional: Attach accessories like the Quick Disconnect, Remote Sampling Probe or Telescoping Sampling Probe to the GCT External Pump using various lengths of sampling hose (up to 75 ft.).

Turning On the Device
To activate the device:

  1. Press and hold down the power button for 5 seconds.
  2. Once the device is activated, the start-up sequence will display the following behavior:
  3. Power LED is green and begins to flash slowly.
  4. Audible Alarm beeps once.
  5. Flow LED is green and begins to flash slowly.

LED Indicators

LED Pattern Description
Flow LED LED OFF Status: Pump motor is OFF
Flow LED GREEN solid Pump is ON, normal operation
Flow LED RED fast flash & beep Warning: Pump is blocked
Power LED LED OFF During Pump Operation: LED OFF (Flow LED solid GREEN)
Power LED ORANGE slow flash every 2 sec. Battery has > 40%
Power LED ORANGE flash every sec. Between 20% to 40%
Power LED RED fast flash & beep every 10 sec. Between < 20%, Warning: < 20

min. left
Power LED| RED faster flash & beep every 5 sec.| Warning: < 10 min. left
Power LED| RED very fast flash & beep every 2 sec.| Warning: < 5 min. left
Power LED| RED very fast flash & very fast beep| Powering down
Charging LED| LED OFF| Not charging
Charging LED| ORANGE flash equal on and off| Charging in progress
Charging LED| GREEN slow flash every 2 sec.| Fully charged

Frequently Asked Questions (FAQ)

  • Q: Where can I find additional information about the GCT External Pump?
    A: For additional information on the GCT External Pump regarding programming, bump testing, maintenance, etc., please refer to the GCT External Pump User’s Manual. The manual and other helpful videos & information are available for viewing or download at www.gascliptech.com.

  • Q: What is the contact information for Gas Clip Technologies?
    A: You can visit their website at www.gascliptech.com.

GCT External Pump
Quick-Start Guide

LED Indicators

READ FIRST BEFORE OPERATION
The GCT External Pump is a personal safety device designed to extend the capabilities of Gas Clip Technologies’ diffusion gas detectors (Single Gas Clip, Single Gas Clip Plus, Multi Gas Clip, MGC Simple and MGC Simple Plus). Before operation, ensure that you have been properly trained on the use and daily testing of the device and the appropriate actions to take in the event of an alarm condition.

READ GCT EXTERNAL PUMP USER’S MANUAL BEFORE OPERATION

Device Components

Entry Description
1 Infrared Communication Window
2 Audible Alarm
3 Power LED
4 Power Button
5 Charging LED
6 Flow LED
7 Alligator Clip
8 Gas Inlet Port
9 Pellet Filter
10 Hydrophobic Filter
11 Certification Label
12 Model and Serial Label
13 Gas Outlet Port
14 Charging Port

Included in the box: GCT External Pump, charger, 3 ft. hose, 10 ft. hose, stainless steel diffusion stone, 10 additional filters (5 hydrophobic & 5 particulate)

Set Up

Connect the 3 ft. hose from the gas outlet port to a Gas Clip Technologies detector with a calibration cap. Next, connect the 10 ft. sampling hose from the gas inlet port to the diffusion stone. Accessories, such as the Quick Disconnect, Remote Sampling Probe or Telescoping Sampling Probe, can also be attached to the GCT External Pump with various lengths of sampling hose (up to 75 ft.).

Turning On the Device
To activate, press and hold down the power button for 5 seconds. Once the device is activated, the start-up sequence will display the following behavior:

  1. Power LED is green and begins to flash slowly.
  2. Audible Alarm beeps once.
  3. Flow LED is green and begins to flash slowly.

For flow, power and charging status, refer to LED Indicators section.

Blocked Flow Test
Before each day’s use, conduct a blocked flow test to ensure the pump is fully operational. With the power on, block the free end of the sampling hose which is attached to the gas inlet port. The device will display the following behavior:

  1. Pump motor shuts down.
  2. Audible alarm beeps continuously indicating a flow fault.
  3. Flow LED turns red and flashes quickly.

Upon successful completion of the blocked flow test, press the power button to reactivate the device.

Bump Test
Before each day’s use, complete a bump test of the detector connected to the GCT External Pump. Refer to the GCT External Pump User’s Manual for instructions.

Low Battery Warning

  • A fast, red intermittent flash of the power LED with the audible alarm beep every 10 seconds indicates that (on average) 20 minutes of operation remains. However, the time remaining can vary due to several different factors.
  • In the event of a low battery warning, exit the work area immediately since the GCT External Pump could turn off at any time.

Turning Off the Device
Press and hold down the power button for 5 seconds until the 3 LEDs (power LED, flow LED, charging LED) turn off, then release the button.

Additional Questions?

  • For additional information on the GCT External Pump regarding programming, bump testing, maintenance, etc., please refer to the GCT External Pump User’s Manual. The manual and other helpful videos & information are available for viewing or download at www.gascliptech.com .
  • Contact Information:
    • Gas Clip Technologies, Inc.
    • 305 W. FM 1382, Suite 540, Cedar Hill, TX 75104 USA
    • Phone: 1.972.775.7577
    • Toll Free: 1.877.525.0808
    • Fax: 1.972.775.2483
    • Website: www.gascliptech.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

gas clip User Manuals

Related Manuals