The Multi Gas Clip Pump is a personal safety device designed to detect the presence of hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2), and combustible gases (LEL). Before the operation, ensure that you have been properly trained on the use of the detector and the appropriate actions to take in the event of an alarm condition.
Display Components
When a Gas Reading (5) exceeds its alarm threshold, the detector will go into
visual, vibrating, and audible alarm. On the display, the icon will appear
beside the Alarm Condition (1) and the associated Gas Identifier (6) will
flash off and on continuously.
Warning – Users must familiarize themselves with the icons in both alarm
and non-alarm states.
Warning – If the display is missing icons, or cannot be clearly read,
discontinue use and contact Gas Clip Technologies.
Warning – The IR LEL sensor will not detect hydrogen (H2) or acetylene
(C2H2) gases however, due to their cross-sensitive nature, the CO sensor will
go into alarm well below 10% LEL.
Factory Default Alarms
Sensor | LOW | HIGH | TWA | STEL |
---|---|---|---|---|
H²S | 10 ppm | 15 ppm | 10 ppm | 15 ppm |
CO | 35 ppm | 200 ppm | 35 ppm | 50 ppm |
O² | 19.50% | 23.50% | ||
LEL | 10% | 20% |
Turning On the Detector
To activate the detector, press and briefly hold down the power/menu button.
Activation tone will sound. Each Gas Identifier will show a chasing “0” for
the Gas Reading while it is stabilizing and self-testing. Once all Gas
Identifiers have completed the warm-up and stabilization sequence, < 65
seconds, the detector is ready to detect all applicable gases. Display will
show:
Before
each use, check that the gas inlet and alarm port are clear of any debris or
obstructions.
To confirm that there are no leaks in the sampling system, perform a blocked
flow test 1.) daily and 2.) any time the sampling system is changed.
When the gas flow is blocked, the detector will go into alarm and disable the
pump. Press the power/menu button to reactivate the pump.
Turning Off the Detector
Press and hold down the power/menu button until the “OFF” countdown is complete. During the countdown, the detector will beep and flash 4 times then turn off. The display will show:
Manually Calibrating the Detector
Continuously hold down the power/menu button through the “OFF” countdown and
the “CAL” countdown that follows. During these countdowns, the detector will
beep and flash 8 times with a pause between countdowns.
The display will show:
Release the power/menu button when the display shows “AUTO ZERO” followed by “APPLY GAS”. Connect a hose from a demand flow regulator on a gas cylinder to the detector’s gas inlet and apply the gas. Calibration is complete once the detector goes into alarm and the next calibration due date is displayed. Turn gas off and remove hose from regulator. The display will show:
Battery Information
Low Battery Warning – With 20 minutes of run time left, the detector will
beep, flash and display “LOW BAT”. Notifications will continue periodically
until the battery expires and the detector performs an automatic shutdown.
Charging – While charging, the battery icon will cycle and the detector will
display an approximate charge percentage. The full charge occurs in 4-6 hours.
For the fastest charging, charge while the detector is turned off.
Warning – DO NOT charge the detector in a combustible atmosphere.
Warning – DO NOT charge the detector in temperatures above 104°F (40°C)
or below 32°F (0°C).
Additional Questions?
For additional information on the Multi Gas Clip Pump gas detector regarding programming, bump testing, calibrating, etc., please refer to the Multi Gas Clip Pump User’s Manual. The manual, videos, and other helpful information are available for viewing or download at www.gascliptech.com.
Contact Information
Gas Clip Technologies, Inc.
305 W. FM 1382, Suite 540
Cedar Hill, TX 75104 USA
Phone: +1.972.775.7577
Fax: +1.972.775.2483
Toll-Free: 1.877.525.0808
E-mail: info@gascliptech.com
Website: www.gascliptech.com
MGC- PUMP-QSG v1.04
Documents / Resources
| gas
Clip MGC-IR-PUMP Multi Gas Clip
Pump
[pdf] User Guide
MGC-IR-PUMP, Multi Gas Clip Pump, MGC-IR-PUMP Multi Gas Clip Pump, Gas Clip
Pump, Clip Pump, Pump
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>