EUROtops S 8725 Touch Radio Controlled Weather Station Instructions

June 15, 2024
EUROtops

WIRELESS THERMO-HYGROMETER RCC CLOCK
S 8725 / RS8725ECM

Warning: Please read this instruction manual carefully before using the instrument and keep it for future use.

S 8725 Touch Radio Controlled Weather Station

1 « Snooze/Light » button
2 Window Open/Closed indicate
3 Indoor temperature and humidity
4 Colorful wet comfort index
5 Alarm On/Off
6 °C/F° selectable
7 In/Out temperature Max/Min records
8 Outdoor channels
9 Outdoor temperature and humidity
10 Up to 3 RF outdoor channels
11 Compare with indoor and outdoor humidity
12 RCC symbol
13 Time
14 Mould warning humidity
15 Outdoor sensor

SAFETY INSTRUCTIONS

  1. The device is intended exclusively for private and not for commercial use. Only use this device as describe in this instruction manual.
  2. Before to use, make sure that the supply voltage corresponds with the voltage marked on the rating label.
  3. Do not place any part of this appliance in water or any other liquid.
  4. Do not handle the unit or plug with wet hands.
  5. When disconnecting the cable, always pull at the plug; do not pull on the cable itself.
  6. When using the device, always pull the power cord completely from its housing to prevent overheating.
  7. If the cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid an electric shock.
  8. Never try to repair it by yourself. It must be repaired by the manufacturer or its service agent or a similarly qualified person in order to avoid an electric shock.
  9. The power cable must be checked regularly to avoid damage. If the power cable is damaged it must be replaced by a qualified service center to avoid any danger.
  10. Always place your device on a dry surface.
  11. Do not use outdoors.
  12. Do not let the power cord on the edge of a table or work surface, and prevent it comes into contact with hot surfaces.
  13. Keep it away from heat sources such as radiators, to avoid deformation of plastic parts.
  14. Do not use coarse or abrasive sponges/cloths or steel wool to clean the appliance.
  15. This unit is not designed to be operated by means of an external timer or a separate remote-control system.
  16. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capacities, or by persons lacking in experience or knowledge, unless they are supervised or instructed on the use of this apparatus by a person responsible for their safety. Children should be supervised to ensure they do not play with this appliance.

INITIAL OPERATION

Obstacles can severely impair the of the transmission.
We recommend a minimum distance of 2.5 meters to all sources of interference, such as televisions or computer monitors
Radio receiving is weaker in rooms with concrete walls (e.g.: in cellars) and in offices. In such extreme circumstances, place the unit close to the window.
Protect the transmitter against any direct sunlight penetration.

A- First use :
Using with batteries :

  • Open the battery compartment on the rear side of the outdoor remote sensor and insert the AA batteries. Pay attention to observe the correct polarity. Close in the battery compartment
  • Open the battery compartment on the rear side of the receiver and insert the AA batteries. Pay attention to observe the correct polarity. Close the battery compartment.

Using with USB cable :

  • Insert the jack plug of cable at back side of weather station then insert the power adaptor included into house socket.
  • When you insert the batteries or the cable, all the icon on the LCD display will briefly light up for 3 seconds, and you will hear a beep tone, and detect indoor temperature & humidity.
  • The receiver will now start to make a connection to the outdoor remote sensor. This operation takes about 3 minutes

B- Backlight:
When using batteries only, briefly press the SNOOZE/LIGHT ① button to activate the display lighting for 10 seconds.
When using the cable, the display is always light up. Press the SNOOZE/LIGHT ① to have higher level of brightness for about 10 seconds.

Time and date settings

Reception of the Radio signal:

  • The clock automatically starts the DCF signal search after 3 minutes of any restart or changing of new fresh batteries. The radio mast icon starts to flash.
  • The clock automatically carries out the synchronization procedure with the DCF signal to correct any deviations to the exact time. If this synchronization attempt is unsuccessful (the radio mast icon disappears from the display), the system will  automatically attempt another synchronization at the next full one hour. This procedure is repeated automatically up to total 5 times.
  • To start manual DCF signal reception, press and hold button more than 3 seconds. If no signals received within 7 minutes, then the DCF signal search stops (the radio mast icon disappears) and start again at the next full one hour.
  • During the radio control time receiving reception, to stop searching radio signal, press and hold button more than 3 seconds

Time of automatic RCC signal receiving everyday(time zone:0):1:00 a.m., 2:00 a.m., 3:00 a.m.,4:00 a.m. 5:00 a.m. Automatically entering RCC reception, with mandatory reception from 1 to 3 o’clock. If received at 3 o’clock, it will not be received on the same day. Otherwise, it will be selected to receive from 4 to 5 o’clock. After 5 o’clock, regardless of whether the reception is successful, RCC will not be received on the same day.

F.Y.I.:

  • A flashing radio mast icon indicates that the DCF signal reception has started
  • A continuously displayed radio mast icon indicates that the DCF signal was received successfully
  • We recommend a minimum distance of 2.5 meters to all sources of interference, such as televisions or computer monitors
  • Radio reception is weaker in rooms with concrete walls (e.g.: in cellars) and in offices. In such extreme circumstances, place the system close to the window.
  • During the radio control time receiving mode, only the button function, other button operation has no function, if you want to carry out other functions of operation, please press and hold the button more than 3 seconds to exit the RC receiving mode.

Manual time setting
You can set the time manually: if the signal cannot be received or if you prefer to set the time yourself, in this case to stop RCC reception press the key for 3 seconds.

  • Press the key for approximately 3 seconds. The hour flashes.
  • Press or to set the time.
  • Press key again to confirm entry. The minutes flash.
  • Press or to set the minutes.
  • Press again to confirm entry. The time zone flashes.
  • Press or to set the time zone.
  • Press again to confirm entry. The time format flashes.
  • Press or to select 12 or 24h display. Press again to confirm entry and exit time settings.

After 20 seconds without entry, the weather station exits settings and returns to normal display mode.

Alarm setting

  • Press the key to enter the alarm settings.
  • Press the key to activate the alarm.
  • Press for at least 3 seconds to enter settings. The alarm time flashes.
  • The default alarm time is 6:00. Press or to change the alarm time.
  • Press to confirm your entry. Minutes flash.
  • Press or to set the minutes.

After 20 seconds without input, the weather station exits the settings and switches to normal display mode.
At the set time, the alarm sounds. If you do not deactivate the alarm, it sounds for 2 minutes and then stops automatically. After 24 hours, the alarm will sound again automatically.
When the alarm sounds, the rhythm increases crescendo until it’s multiplied by 4.
To stop the alarm press the SNOOZE/LIGHT button ①, the alarm will sound again 5 minutes later. You can activate the snooze up to 7 times.
To stop the alarm permanently, press any button except SNOOZE/LIGHT ①.

Temperature and humidity

  • Temperature: Press the button to choose whether to display the temperature in degrees Celsius °C or Fahrenheit °F
    Indoor temperature measurement range 0°C ~50°C
    When the temperature is above 50°C, the display shows “HH.H”.
    When the temperature is below -9.9°C, the display shows “LL.L”.
    Outdoor temperature measuring range -40°C ~60°C
    When the temperature is above 60°C, the display shows “HH.H”.
    When the temperature is below -40°C, the display shows “LL.L”.

  • Min./max. indicator for the last 24 hours :
    Press the button to see the max. temperature and humidity recorded in the last 24 hours.
    Press again to see the minimum temperature and humidity recorded in the last 24 hours.
    While reading the min/max values, press the button for at least 3 seconds to clear the history.

Mold alarm setting

  • Press twice the button to enter the mold alert settings.
  • Press to activate the alarm. The default mold alarm value is 65%.
  • Press the key for at least 3 seconds. The humidity level flashes.
  • Press or to select 60%, 65%, 70% or 75%.

The mildew alarm uses indoor humidity values and is not linked to outdoor humidity.
When indoor humidity exceeds the set threshold, there’s a risk of mould formation, the buzzer sounds for 1 minute and the “MOULD ALERT” symbol flashes.
During the alarm process, press any key to stop the audible alarm, but the “MOULD ALERT” symbol continues to flash until the measured indoor humidity is below the preset mould alarm value, at which point “MOULD ALERT” stops flashing.

Comfort index

The comfort index ④ uses indoor humidity values and is not linked to outdoor humidity.
Comfort index Humidity level

COMFORT LEVEL RELATIVE HUMIDITY
TOO WET 85% to 95%
WET 66% to 84%
COMFORT 45% to 65%
DRY 31% to 44%
TOO DRY 20% to 30%

Note:

  1. If the humidity is between 45% and 65% and the temperature is between 20 ℃ and 25 ℃, the display shows the corresponding comfort index.
  2. If humidity is between 45% and 65% but temperature is not between 20 ℃ and 25 ℃, no comfort index is displayed.

Window indication

To help you control humidity levels and the risk of mold, this device compares indoor and outdoor humidity levels and tells you when you should air your home.

Indoor humidity| Compare with indoor and outdoor humidity| Open the window indication| Close the window indication
---|---|---|---
DRY| MORE WET| Yes| No
DRY| NO CHANGE| No| No
DRY| MORE DRY| No| Yes
COMFORT| MORE WET| No| No
COMFORT| NO CHANGE| No| No
COMFORT| MORE DRY| No| No
WET| MORE WET| No| Yes
WET| NO CHANGE| No| No
WET| MORE DRY| Yes| No

CARE AND MAINTENANCE

Clean the product only with a dry or slightly damp, lint-free cloth.
Do not use abrasive cleaners to clean the unit.

FEATURES

  • Material: ABS
  • Power supply: DC 5V 0.15A mains adapter included and 2 AA batteries for sensor not included
  • Frequency: 433 Mhz
  • Indoor temperature range: 0°C to 50°C
  • Humidity percentage range: 20-95%
  • Outdoor temperature range: -20°C to 60°C

The European directive 2012/19/EC about electronic and electric waste, requires that you can’t throw away defective domestic appliance with common waste. Used device has to be collect separately to optimize the recuperation rate and the recycling of the  materials to reduce the impact on the health and the environment.

Precision and precautions about the battery use

  • Throwing away a used battery in the environment or with household waste pollutes and avoids the recuperation of reusable materials.
  • It is important to limit the battery consumption and to respect the following rules:
  • Favor alkaline battery (last longer than saline battery) and when it’s possible use rechargeable battery.
  • Leave used batteries and accumulators in adapted containers that you can find in some retailers. In that way, metals don’t pollute the environment and the health.
  • Battery has to be inserted by respecting the polarity show on the apparel and the battery. An incorrect positioning can damage the apparel, cause leaking and even provoke fire and the explosion of the battery.
  • To assure a good functioning, battery has to be in a good condition. If there is a problem, put new battery.
  • Never try to recharge battery not made for this. It could leak, warm up, cause fire or explode.
  • Replace all the battery at the same time. Never mix up alkaline battery with saline battery.
  • Used battery has to be removed.
  • Also, remove the battery if you’re not using the apparel for a long time.
  • Never try to short-circuit the terminal of a battery.
  • Never throw away the battery in fire because they can explode.
  • Take out the accumulator from the apparel before reload it.
  • We recommend that an adult watch if a child change the battery to respect those rules.
  • If you swallow a battery, go immediately to your doctor or the hospital.
  • For the best ongoing performance, we recommend using only fresh, high-quality, alkaline batteries.

Declaration of Conformity
Captelec declares that this product S 8725 conforms to the guidelines 2014/53/EU, 2011/65/EU, 2014/35/EU and 2014/30/EU
The full text of the EU declaration of conformity is attached at the end of the package leaflet.
This declaration is invalid if changes have been made to the product for which we have not agreed.
In Croix, 07-2023
CAPTELEC

Imported by : CAPTELEC, 59170 Croix – FRANCE

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals