TIS258 Digital Multimeter Instruction Manual
- June 15, 2024
- TIS
Table of Contents
- TIS258 Digital Multimeter
- Product Information
- FAQ
- Introduction
- Accessories
- SAFETY INSTRUCTIONS
- Safety Symbols
- Warranty
- Instrument Layout, display information & symbols
- Description of Measurement Operation
- Technical Specifications
- Installation / Replacement of Battery & Fuse Protection
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TIS258 Digital Multimeter
Product Information
Specifications
- Model: TIS258
- Product: Digital Multimeter
- Instruction Manual Version: 2.00
Accessories
- Test lead(s) (Red + Black)
- 9V PP3 alkaline battery (1)
- User Manual (1)
Safety Instructions
- Once the battery indicator appears, please replace the battery. Low battery level can produce inaccurate results.
- Do not use/store the instrument in high temperature, humid, flammable, or electromagnetic environments as this could result in injury, damage to the instrument, and/or inaccurate results.
- If the instrument/equipment is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired.
- Do not connect test leads to live systems or hazardous voltages unless stated within the manual.
Safety Symbols
- Warning & caution safety label
- Double insulation
- DC (Direct Current)
- AC (Alternating Current)
- Low battery
- Dangerous high voltage!
- Buzzing on-off
- Earthing
- Comply with EC standard
- CAT IV: Applicable to test and measuring circuits connected at the source of the building’s low-voltage MAINS installation.
Instrument Layout, Display Information & Symbols
The TIS258 Digital Multimeter is a 31/2-digit multimeter with the following capabilities/functionality:
Function | Range | Max. Display |
---|---|---|
Diode | 2000 counts | Yes |
Continuity | – | Yes |
DC Voltage | 200mV-500V | – |
AC Voltage | 200mV-500V | – |
DC Current | – | Yes |
AC Current | – | Yes |
Resistance | 200-20M | – |
Battery | 9V x 1 | – |
Temperature | -4-1382 | – |
Installation / Replacement of Battery & Fuse Protection
To install/replace the battery and fuse, follow these steps:
- Make sure the instrument is switched off.
- Locate the battery compartment on the back of the instrument.
- Open the battery compartment cover.
- Insert a 9V PP3 alkaline battery into the battery compartment, ensuring correct polarity.
- Close the battery compartment cover securely.
- To replace the fuse, if necessary, refer to the user manual for detailed instructions.
FAQ
Q: How often should I replace the battery?
A: The battery should be replaced when the battery indicator appears or when the instrument is not functioning properly.
Q: Can I use the instrument in high humidity environments?
A: No, it is not recommended to use the instrument in high humidity environments as it may result in inaccurate readings and damage to the instrument.
Q: What is the warranty period for this product?
A: The warranty period for new instruments is 1 year from the date of purchase by the user. A copy of the original purchase invoice may be requested to validate the purchase date.
Q: Can I perform measurements on live systems?
A: No, do not connect test leads to live systems or hazardous voltages unless stated within the manual. This can be dangerous and may result in injury or damage to the instrument.
Q: Where can I get service/calibration/repair for the instrument?
A: For service/calibration/repair requirements, please contact Test Instrument Solutions Limited at the following address:
TEST INSTRUMENT SOLUTIONS LIMITED UNIT 12/14, LUDDITE WAY BUSINESS PARK RAWFOLDS WAY CLECKHEATON BD19 5DQ
Instruction Manual Version 2.00
Introduction
Thank you for purchasing the TIS258
The TISS258 Digital Multimeter, is a 31/2-digit multimeter with the following
capabilities/functionality:
Function| Range| Function|
---|---|---|---
Max. Display| 2000 counts| Diode| Yes
Basic Accuracy| 0.5%| Continuity| Yes
DC Voltage| 200mV-500V| Data Hold| Yes
AC Voltage| 200mV-500V| Back Light| Yes
DC Current| 200µA-10A| Auto Power off| Yes
AC Current| 200µA-10A| Manual Range| Yes
Resistance| 200W-20MW| Battery| 9V x 1
Temperature| -20℃-750℃| Diode| Yes
-4℉-1382℉| Continuity| Yes
Accessories
- Test lead(s) (Red + Black) —————————————————————————-2
- 9V PP3 alkaline battery—————————————————————————- 1
- User Manual —————————————————————————————— 1
SAFETY INSTRUCTIONS
Warning – Please read and follow the following:
Before using the instrument, test leads and / or the adaptors please ensure
there are no signs of damage as this could result in electrical shock and / or
inaccurate results.
- Once the battery indicator appears, please replace the battery. As low battery level can produce inaccurate results.
- Do not use / store the instrument in high temperature, humid, flammable, or electromagnetic environments as this could result in injury, damage to the instrument and / or inaccurate results.
- If the instrument / equipment is use in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired.
- Do not connect test leads to live systems or hazardous voltages unless stated within the manual.
Safety Symbols
Warranty
NEW INSTRUMENTS HAVE A WARRANTY PERIOD OF: 1 YEAR FROM THE DATE OF PURCHASE BY THE USER.
(A copy of the original purchase invoice may be requested to validate the purchase date).
- This warranty period includes parts and labor only.
- Any unauthorized repair / adjustment will void the warranty.
For service / calibration / repair requirements, please contact
TEST INSTRUMENT SOLUTIONS LIMITED UNIT 12/14, LUDDITE WAY BUSINESS PARK RAWFOLDS WAY CLECKHEATON BD19 5DQ
Tel: 01274 752407
Email: SALES@TIS-TIC.CO.UK
Instrument Layout, display information & symbols
- LCD display
- Select Button (Switch the measurements of AC, DC current; Temperature, Diode & Continuity check)
- MAX Hold button
- Rotary/ Function Selector Switch
- 10A, Input Terminal
- LED Indicator
- Backlight Button
- Data Hold Button
- COM, Input Terminal
- V,Ω,mA, Input Terminal
Description of Measurement Operation
AC / DC Voltage Measurement
- Set the rotary switch to the voltage position. (V / V~)
- If required press the select button to change the voltage sine wave from DC V to AC (V~)
- Insert the black test lead banana plug into the negative COM input terminal & insert the red test lead banana plug into the positive V/ΩmA input terminal.
- Connect test leads to the conductors to be tested.
- Read the voltage in the LCD display.
PLEASE NOTE: That the polarity of red test lead must be connected to the positive conductor to indicate the positive voltage measurement when conducting DC voltage measurements.
AC/DC Current Measurement
- Select the rotary switch to the appropriate current measurement function & range.
- Insert black test lead banana plug into the negative COM input terminal.
- To perform current measurements less than 200mA insert the red test lead banana plug into the mA Input terminal or for current measurements between 200mA to 10A insert the red test lead banana plug into the 10A input terminal
- Disconnect the circuit under test then connect the test leads in series with the circuit.
- Turn the power on and read the measurement value displayed.
If OL (Over Limit) is displayed, increase the measurement range/function.
Diode Test
- Set the rotary switch to the “ ” position.
- Connect the black test lead to the “COM” terminal and the red test lead to the “VΩ:” input terminal.
- Pres the “SEL” button to select the diode function (If required)
- Connect the test leads to the diode, test both the “Forward Bias & Reverse Bias” of the diode under test. Open circuit measurements will be indicated as OL on the display,
Continuity Indication / Buzzer Test
- Set the rotary switch to the “ ” position.
- Connect the black test lead to the “COM” terminal and the red test lead to the “VΩ:” input terminal.
- Pres the “SEL” button to select the continuity function (If required)
- Connect test leads to the circuit under test.
- Measurement will be displayed and the audible indicator will sound, when measurements are under 70Ω.
Resistance Measurement
- Set the rotary switch to the required resistance range.
- Insert the black test lead banana plug into the negative COM input terminal & insert the red test lead banana plug into the positive V/ΩmA input terminal.
- Connect test leads / probes to the measuring points
- Read resistance measurement displayed on the LCD.
If OL (Over Limit) is displayed, increase the measurement range/function.
Temperature Measurement
- Set rotary switch to the “°C°F” function.
- Select the measurement type by press the “SEL” button.
- Connect the thermocouple by inserting the black lead in to the COM input terminal & insert the red lead in to the V/ΩmA input terminal.
- Place the thermocouple either on or in the vicinity of the object / room under test.
- Wait while measurement stabilizes.
- Read temperature measurement displayed on the LCD.
Technical Specifications
DC Voltage
AC Voltage
DC Current
AC Current
Resistance
Diode and Continuity
Temperature
Installation / Replacement of Battery & Fuse Protection
WARNING:
- To avoid electric shock, disconnect the test leads from any source of voltage before removing the back cover or the battery or fuse covers.
- To avoid electric shock, do not operate the meter until the battery and fuse covers are in place and fastened securely.
Battery Installation / Replacement.
To avoid the false readings, replace the battery as soon as the battery indicator appears.
- Turn power off and disconnect the test leads from the meter.
- Open the rear battery cover..
- Insert the battery into battery holder, observing the correct polarity.
- Put the battery cover back in place & secure.
Replacing the Fuse(s)
- Turn power off and disconnect the test leads from the meter.
- Remove the battery cover and the battery.
- Remove the screws securing the rear cover.
- Remove the defective fuse and install an identical fuse. (F200mA or F10A Fuse)
- Replace and secure the rear cover, battery and battery cover.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>