SHOW CAS-304 Column Array Speakers User Manual
- June 15, 2024
- SHOW
Table of Contents
User’s Manual
COLUMN ARRAY SPEAKERS CAS-304
CAS-308
CAS-312
SAEFTY RELATED SYMBOLS
IMPORTANT!
Please read this manual carefully before operating this unit for the first
time.
All rights reserved to SEIKAKU. All features and content might be changed
without prior notice. Any photocopy, translation, or reproduction of part of
this catalogue without written permission is forbidden. Copyright © 2009
SEIKAKU GROUP
The symbol is used to indicate that some hazardous live terminals are involved
within this apparatus, even under the normal operating conditions.
The symbol is used in the service documentation to indicate that specific
component shall be only replaced by the component specified in that
Documentation for safety reasons.
Protective grounding terminal.
Alternating current /voltage.
Hazardous live terminal .
ON: Denotes the apparatus turns on.
OFF: Denotes the apparatus turns off, bec-ause of using the single pole
switch, be sure to unplug the AC power to prevent any electric shock before
you proceed your service.
WARNING: Describes precautions that should be observed to prevent the
danger of injury or death to the user.
** Disposing of this product should not be placed in municipal waste and
should be separate collection.
CAUTION: Describes precautions that should be observed to prevent danger
of the apparatus.
WARNING
**
-
Power Supply
Ensure the source voltage matches the voltage of the power supply before turning on the apparatus.
Unplug this apparatus during lightning storms or when unused for long periods of time. -
External Connection
The external wiring connected to the output hazardous live terminals requires installation by an instructed person, or the use of ready- made leads or cords. -
Do not Remove any Cover
There are maybe some areas with high voltages inside, to reduce the risk of electric shock, do not remove any cover if the power supply is connected.
The cover should be removed by the qualified personnel only.
No user serviceable parts inside. -
Fuse
To prevent a fire, make sure to use fuses with specified standard (current, voltage, type). Do not use a different fuse or short circuit the fuse holder.
Before replacing the fuse, turn OFF the apparatus and disconnected the power source. -
Protective Grounding
Make sure to connect the protective grounding to prevent any electric shock before turning ON the apparatus.
Never cut off the internal or external pro-tective grounding wire or disconnect the wiring of protective grounding terminal. -
Operating Conditions
This apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on this apparatus.
To reduce the risk of fire or electric shock, do not expose this apparatus to
rain or moisture.
Do not use this apparatus near water.
Install in accordance with the manufacture-r’s instructions. Do not install
near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including am-plifiers) that produce heat. Do not block any
ventilation openings.
No naked flame sources, such as lighted candles, should be placed on the
apparatus.
-
Read these instructions.
-
Follow all instructions.
-
Keep these instructions.
-
Heed all warnings.
-
Only use attachments/accessories spec- ified by the manufacturer.
Power Cord and Plug
Do not defeat the safety purpose of the polarized or grounding type plug.
A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety.
If che provided plug does not fit into your outlet, consult an electrician for replace-ment of the obsolete outlet.
Protect the power cord from being walk-ed on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. -
Cleaning
When the apparatus needs a cleaning, you can blow off dust from the apparatus with a blower or clean with rag etc.
Don’t use solvents such as benzol, alcohol, or other fluids with very strong volatility and flammability for cleaning the apparatus body.
Clean only with dry cloth. -
Servicing
Refer all servicing to qualified personnel. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
The mains plug is used as the disconnect device, the disconnect device shall remain readily operable.
Please read the instructions in details before you use, and follow the
contents to do the most proper installation. After you have made the proper
installation, please keep this instruction well for your references at any
time.
If you would like to do any changes for the installation regarding this
product, please must make sure if the specifications are correct or not.
Otherwise, the incorrect installation will probably result in the permanent
damage to this product, therefore, please use it with cautions.
Cautions:
- Absolutely not to do the installation that exceeds the specifications of this products because it will result in affecting the life and the capacity with regard to this product.
- Keep away from the place that wets in rain directly if installing at outside.
- Do not clean the appearance of the column speaker with an organic solvent or alcoholic detergent.
- Do not repair or disassemble the product yourself if there is any damage or unusual situation, please should contact the person in charge of service immediately.
INTRODUCTION
The CAS series is a professional column array speaker developed by SHOW. With 1.0mm mesh and
- 0mm grille, it can effectively protect unit from external damage and prevent dust into the speaker.
Cabinet is made by aluminum alloy with coating, to make delicate touch. 8 pieces 3 ” full-range horn unit with linear paper cone , cloth surrounding can achieve high sensitivity. The system apply power transformers to switch power, effectively protect the units. To prevent high power input signal damage units, they can be used in parallel to avoid causing damage to the PA amplifier with low impedance. Locked bracket screws to fixed plate inside cabinet. The fixing plate with 3 mm thick iron can effective decompose the bracket pull force.
CAS-304 / CAS-308
-
Make sure the expansion screws of mounting brackets can filmy support the product weight before installation to avoid causing the injuries of the facilities and a worker if there is a falling.
-
Make sure the bracket is installed in vertical position and install expansion screw in the identified location.
-
Lock the bracket (in attached) to the wall enough tightly and ensure it’ s vertical between bracket and wall.
-
Remove the 6*M8 screws on back of column and fix it to the racket via the screws( in attached).
Please make the column straight and firmly locked. -
Adjust the column to appropriate angle with bracket adjustable angle vertical 0 °~ 30 °, horizon -90 ° ~ 90 °.
-
Please first confirm the system you connected output of 100V, 70V. And make the cables connected.
CAS-312
- Make sure the expansion screws of mounting brackets can filmy support the product weight before installation to avoid causing the injuries of the facilities and a worker if there is a falling.
- Make sure the bracket is installed in vertical position and install expansion screw in the identified location.
- Lock the bracket (in attached) to the wall enough tightly and ensure it’ s vertical between bracket and wall.
- Remove the 12*M8 screws on back of column and fix it to the racket via the
screws( in attached).
Please make the column straight and firmly locked. - Adjust the column to appropriate angle with bracket adjustable angle
horizon -90 ° ~ 90 °.
6)Please first confirm the system you connected output of 100V, 70V. And adjust band switch to the correct position, also the input signal must be connected correctly.
ACCESSORY
BACK PANEL DESCRIPTION
CAS-304B / CAS304W
POWER SELECTIONS
- Do not connect BLACK and WHITE for 70V input
- Do not connect BLACK and BROWN for 100V input
CAS-308B / CAS308W
POWER SELECTIONS
- Do not connect BLACK and WHITE for 70V input
- Do not connect BLACK and BROWN for 100V input
CAS-312B / CAS312W
POWER SELECTIONS
- Do not connect BLACK and WHITE for 70V input
- Do not connect BLACK and BROWN for 100V input
SYSTEM CONNECTION PLATE
CH1/CH2 loaded with 70V, dual channel input:
- Select “MONO/DUAL” at ” DUAL” position, dual channel input;
- CH1/CH2 output select at ” 70V” position, both loaded with rated 70V speaker;
- Select “L/H CUT” at ” ON” position, to prevent low frequency protection and improve the transmission efficiency. Applicable to Public Address System.
CH1/CH2 loaded with 100V, dual channelinput:
- Select “MONO/DUAL” at ” DUAL” position, dual channel input;
- CH1/CH2 output select at ” 100V” position, both loaded with rated 100V speaker;
- Select “L/H CUT” at ” ON” position, to preventlow frequency protection and improve the transmission efficiency. Applicable to Public Address System;
TECHNICAL SPECIFICATIONS
Model Passive | CAS-304B / CAS-304W |
---|---|
System Type | Column Array Speaker |
Input Voltage | 70V/100V |
Transformer selectable Power | 5W / 10W / 20W / 40W |
System Impedance | 70V 1000Ω / 500Ω / 250Ω / 125Ω |
100V 2000Ω / 1000Ω / 5000Ω / 250Ω
Sensitivity (1w/1M)| 93dB
Max SPL(1M)| 114dB
Frequency Response(-6dB)| 150Hz-18KHz
Speaker| 4×3″ full range speaker, 20mm Voice Coil
Angle of coverage(HxV)| 120°x10° @ 4 kHz
Connect| Cable conductor
Enclosure Construction| Body in extruded aluminum, resistant paint, 1.0mm
aluminum grille
Suspension/Mounting| 6×M8 Points For Mounting
Dimensions(H×W×D)| 448mm(17.6″)×121mm(4.8″)×140mm(5.5″)
Net weight| 5.2KG/11.46Ibs
Model Passive| CAS-308B / CAS-308W
---|---
System Type| Column Array Speaker
Input Voltage| 70V/100V
Transformer selectable Power| 7.5W /15W / 30W / 60W
System Impedance| 70V 667Ω / 333Ω / 167Ω / 83Ω
100V 1333Ω / 667Ω / 333Ω / 167Ω
Sensitivity (1w/1M)| 95dB
Max SPL(1M)| 116dB
Frequency Response(-6dB)| 150Hz-18KHz
Speaker| 8×3″ full range speaker, 20mm Voice Coil
Angle of coverage(HxV)| 120°x20° @ 4 kHz
Connect| Cable conductor
Enclosure Construction| Body in extruded aluminum, resistant paint, 1.0mm
aluminum grille
Suspension/Mounting| 6×M8 Points For Mounting
Dimensions(H×W×D)| 763mm(30″)×121mm(4.8″)×140mm(5.5″)
Net weight| 8.6KG/18.9Ibs
Model Passive| CAS-312B / CAS-312W
---|---
System Type| Column Array Speaker
Input Voltage| 70V/100V
Transformer selectable Power| 15W / 30W / 60W / 120W
System Impedance| 70V 330Ω / 167Ω / 83Ω / 41Ω
100V 667Ω / 333Ω / 167Ω / 83Ω
Sensitivity (1w/1M)| 99dB
Max SPL(1M)| 125dB
Frequency Response(-6dB)| 120Hz-18KHz
Speaker| 12×3″ full range speaker, 20mm Voice Coil
Angle of coverage(HxV)| 120°x30° @ 4 kHz
Connect| Cable conductor
Enclosure Construction| Body in extruded aluminum, resistant paint, 1.0mm
aluminum grille
Suspension/Mounting| 12×M8 Points For Mounting
Dimensions(H×W×D)| 1112mm(43.7″)×121mm(4.8″)×140mm(5.5″)
Net weight| 13.3KG/29.3Ibs
SHOW® is a registered trademark of
SEIKAKU TECHNICAL GROUP LIMITED
NO.I LANE 17, SEC.2, HAN SHI WEST ROAD, TAICHUNG 40151, TAIWAN
tel: 886-4-22313737 – fax: 886-4-22346757
www.show-pa.com
www.seikaku.hk
www.show-pa.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>