CLAYTON POWER 028-01 Reduce DC Charging Current Instructions

September 9, 2024
CLAYTON POWER

028-01 Reduce DC Charging Current

Specifications:

  • Max DC Charging Current: 30A
  • Solar Input Voltage: Up to 50V DC
  • Maximum Fuse Rating: 60A
  • Cable Sizes: 10 mm2, 4 mm2, 1 mm2
  • Terminal Sizes: 8 mm, 4 mm

Product Usage Instructions:

Connecting LPS II to VW ID.Buzz:

  1. Use a 10 mm2 cable to connect LPS II DC IN to the ID.Buzz’s 12V
    battery. Use an 8 mm ring terminal to connect to the LPS II DC IN
    terminals. Ensure the cable length does not exceed 5 meters.

  2. Place a Mega Fuse in line with the LPS II and battery, ensuring
    it has a maximum rating of 60A.

Connecting Solar Panels:

  1. Connect solar panels to C2 using a 4 mm2 cable and a 4 mm ring
    terminal to connect to the LPS II solar terminal (C2).

Configuring LPS II:

  1. Connect Wakeup (C1) to the DC IN+ terminal using a 1 mm2 wire
    and 4 mm ring terminals.

  2. Connect the LPS remote to the M12 connector labeled “Remote” on
    the back of the LPS II.

  3. To reduce the DC charging current, configure the LPS II to
    charge at 30A.

FAQ:

Q: What is the maximum fuse rating for the LPS II?

A: The maximum fuse rating for the LPS II is 60A.

Q: How long can the cable between LPS II DC IN and the

ID.Buzz’s battery be?

A: The cable length between LPS II DC IN and the ID.Buzz’s
battery must not exceed 5 meters.

This installation diagram shows how to connect an LPS II to a VW ID using both solar panels and an LPS remote, as well as how to configure the LPS II.

Instructions

1. Use a 10 mm2 cable to connect LPS II DC IN to the ID.Buzz’s 12V battery. Use an 8 mm ring terminal to
connect to the LPS II DC IN terminals. See the necessary torque in the table below. Place a Mega Fuse in line with the LPS II and battery. The fuse must have a maximum rating of 60A.

2. To connect solar panels to C2, use a 4 mm2 cable. Use a 4 mm ring terminal to connect to the LPS II solar terminal (C2).

3. In order to connect Wakeup (C1) to the DC IN+ terminal, use a 1 mm2 wire and 4 mm ring terminals.

4. Connect the LPS remote to the M12 connector on the back of the LPS labbeled with “Remote”

5. Reduce the DC charging current by configuring the LPS II to charge at 30A.

LPS Remote

LPS II Back View

Please Note
1. It’s important to set DC Charging to a maximum of 30 A when installing a LPS in a VW ID.Buzz.
2. The 10 mm2 cable between the LPS II DC IN and the 12volt battery in the ID.Buzz must not be more than 5 meters long.
3. The solar input voltage must not exceed 50 volts DC.
Solar panel

Reduce DC Charging Current

Press

to enter Main Menu

3 x

for DC Charging

Press

to enter DC Charging

6 x

for Set current

ID.Buzz 12V Battery

Fuse
60 A

Torque Table

DC IN

14 Nm

DC OUT

14 Nm

C1 / C2 Battery Terminal / Fuse

14 Nm 10 Nm

Press

to set current to 30A

to confirm

Press 2 x

to exit back to main screen

R&D www.claytonpower.com

CBL

MBN

Support/Installation diagram

Installation diagram for LPS II
Vehicle: VW ID.Buzz Cargo

01:00

09-07-2024 1/1