Product Information

Specifications

  • Product Dimensions: 5 inches (width) x 7 inches (height) x 3
    inches (depth)

Usage Instructions

1. Before You Begin

What Is Included:

The following items are included in the package:

  • Main unit
  • AC power cable
  • Mounting brackets
  • User Manual

Unpacking Instructions:

When unpacking the product, please ensure that all the items
mentioned in the “What Is Included” section are present and
undamaged.

Claims:

If any items are missing or damaged, please contact our customer
support within 24 hours of receiving the product.

2. Introduction

Product Overview:

The product is a lighting fixture designed for professional use.
It provides various lighting effects and can be controlled via DMX
or operated in standalone mode.

3. Setup

AC Power:

To power the unit using AC power, follow these steps:

  1. Connect the AC power cable to the power input on the unit.
  2. Plug the other end of the AC power cable into a suitable power
    outlet.

Fuse Replacement:

If the unit’s fuse needs to be replaced, follow these steps:

  1. Unplug the unit from the power outlet.

  2. Locate the fuse compartment on the unit.

  3. Remove the old fuse and replace it with a new one of the same
    rating.

  4. Close the fuse compartment.

Battery Power:

If you want to power the unit using batteries, follow these
steps:

  1. Open the battery compartment located on the back of the
    unit.

  2. Insert the required number of batteries according to the
    specified type and polarity.

  3. Close the battery compartment securely.

Charging the Battery:

If your unit has a rechargeable battery, follow these steps to
charge it:

  1. Connect the AC power cable to the power input on the unit.

  2. Plug the other end of the AC power cable into a suitable power
    outlet.

  3. The battery will automatically start charging. The battery life
    indicator will show the progress of charging.

  4. Once fully charged, disconnect the AC power cable from the
    unit.

Battery Life Indicator:

The battery life indicator on the unit displays the remaining
battery life. It is recommended to charge the battery when the
indicator shows low battery level.

Battery Run Time:

The run time of the unit on battery power depends on various
factors such as brightness level, operating mode, and battery
capacity. On average, it can operate for up to 4 hours on a fully
charged battery.

Mounting:

The unit can be mounted using the provided mounting brackets.
Follow these steps to mount the unit:

  1. Select a suitable location for mounting.

  2. Attach the mounting brackets to the unit using the provided
    screws.

  3. Securely mount the unit to the desired surface using
    appropriate hardware.

Orientation:

The unit can be used in any orientation, including vertical or
horizontal placement. Ensure that it is securely mounted to prevent
any accidental movement during operation.

Rigging:

If you need to rig the unit, it is recommended to consult a
professional rigger for proper installation and safety
measures.

4. Operation

Control Panel Operation:

The control panel on the unit allows you to access various
settings and features. Refer to the Menu Map section for detailed
information on navigating the control panel menu.

Menu Map:

The menu map provides a visual representation of the control
panel menu structure. Use it as a reference to navigate through
different settings and options.

DMX Configuration:

To configure the unit for DMX control, follow these steps:

  1. Access the DMX configuration menu on the control panel.
  2. Set the DMX personality and starting address according to your
    setup requirements.

Gobos:

The unit supports different gobo patterns for creating unique
lighting effects. Refer to the user manual for a list of available
gobos and instructions on changing them.

DMX Values:

The DMX values control various parameters of the unit, such as
intensity, color, and movement. Refer to the user manual for a
detailed explanation of DMX values and their corresponding
effects.

Standalone Configuration:

If you prefer to operate the unit in standalone mode, follow
these steps:

  1. Access the standalone configuration menu on the control
    panel.

  2. Select the desired run mode (e.g., manual mode).

Run Mode:

In the run mode, the unit will automatically cycle through
pre-programmed lighting patterns or follow DMX control signals.

Manual Mode:

In manual mode, you can manually control the unit’s settings
using the control panel buttons. Refer to the user manual for
detailed instructions on using the manual mode.

FAQ

Q: How long does the battery take to charge?

A: The charging time depends on the battery capacity and current
charge level. On average, it takes approximately 4-6 hours to fully
charge the battery.

Q: Can I use rechargeable batteries with the unit?

A: Yes, you can use rechargeable batteries. Ensure that the
batteries are compatible with the unit’s specifications.

Q: How do I change the gobo pattern?

A: To change the gobo pattern, follow these steps:

  1. Access the gobo selection menu on the control panel.

  2. Use the navigation buttons to scroll through available
    gobos.

  3. Select the desired gobo pattern and confirm your
    selection.

Q: Can I connect multiple units together for synchronized

operation?

A: Yes, you can connect multiple units together using DMX cables
to achieve synchronized operation. Refer to the user manual for
detailed instructions on setting up a DMX network.

User Manual

TABLE OF CONTENTS

Table of Contents

1. Before You Begin …………………………………………………………….. 1
What Is Included ………………………………………………………………………………. 1 Unpacking Instructions………………………………………………………………………. 1
Claims ……………………………………………………………………………………………………………. 1
Text Conventions ……………………………………………………………………………… 1 Symbols ………………………………………………………………………………………….. 1 Safety Notes…………………………………………………………………………………….. 2 Battery Charge Notes………………………………………………………………………… 2 FCC Statement of Compliance …………………………………………………………… 3 RF Exposure Warning for North America and Australia………………………….. 3 Disclaimer ……………………………………………………………………………………….. 3
2. Introduction …………………………………………………………………….. 4
Product Overview……………………………………………………………………………… 4 Product Dimensions ………………………………………………………………………….. 5
3. Setup ………………………………………………………………………………. 6
AC Power ………………………………………………………………………………………… 6
Fuse Replacement …………………………………………………………………………………………… 6
Battery Power…………………………………………………………………………………… 6
Charging the Battery ………………………………………………………………………………………… 6 Battery Life Indicator ………………………………………………………………………………………… 6 Battery Run Time …………………………………………………………………………………………….. 6
Mounting …………………………………………………………………………………………. 7
Orientation………………………………………………………………………………………………………. 7 Rigging …………………………………………………………………………………………………………… 7
4. Operation ………………………………………………………………………… 8
Control Panel Operation…………………………………………………………………….. 8 Menu Map ……………………………………………………………………………………….. 8 DMX Configuration……………………………………………………………………………. 9
DMX Personality and Starting Address……………………………………………………………….. 9
Gobos……………………………………………………………………………………………… 10 DMX Values …………………………………………………………………………………….. 10 Standalone Configuration…………………………………………………………………… 12
Run Mode……………………………………………………………………………………………………….. 12 Manual Mode ………………………………………………………………………………………………….. 12
Settings Configuration……………………………………………………………………….. 13
D-Fi Settings …………………………………………………………………………………………………… 13 Pan Reverse …………………………………………………………………………………………………… 13 Tilt Reverse …………………………………………………………………………………………………….. 13 Screen Reverse ………………………………………………………………………………………………. 13 Pan Range ……………………………………………………………………………………………………… 13 Tilt Range……………………………………………………………………………………………………….. 13 Totem Mode ……………………………………………………………………………………………………. 14 Sound Sensitivity……………………………………………………………………………………………… 14 DMX Loss……………………………………………………………………………………………………….. 14 Indicator …………………………………………………………………………………………………………. 14 Flash if DMX……………………………………………………………………………………………………. 14 Run Time………………………………………………………………………………………………………… 14 RF Setting ………………………………………………………………………………………………………. 15 Follow Spot …………………………………………………………………………………………………….. 15 Product Reset …………………………………………………………………………………………………. 15 Factory Reset………………………………………………………………………………………………….. 15 Product Information………………………………………………………………………………………….. 15

Intimidator Free Spot 60 ILS User Manual Rev. 2

PRODUCT NAME
Calibration Menu ………………………………………………………………………………. 16 ILS Mode…………………………………………………………………………………………. 16 Master/Slave Mode …………………………………………………………………………… 16 RFC Remote Control…………………………………………………………………………. 17
RFC-XL Remote Control Operation ……………………………………………………………………. 17
5. Maintenance…………………………………………………………………….. 18
Product Maintenance ………………………………………………………………………… 18
6. Technical Specifications ………………………………………………….. 19 Contact Us ………………………………………………………………………….. 20
Warranty & Returns…………………………………………………………………………… 20
Intimidator Free Spot 60 ILS User

Before You Begin

1. Before You Begin
What Is Included
· Intimidator Free Spot 60 ILS · Power cable

· Omega bracket · Quick Reference Guide

Unpacking Instructions
Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
Claims
If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate a claim. Keep the box and contents for inspection. For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.

Text Conventions

Convention
1­512 50/60 Settings
ON

Meaning
A range of values A set of values of which only one can be chosen A menu option not to be modified A key to be pressed on the product’s control panel A value to be entered or selected

Symbols
Symbol

Meaning

Electrical warning. Not following these instructions may cause electrical damage to the product, accessories, or the user.

Critical installation, configuration, or operation information. Not following these

!

instructions may make the product not work, cause damage to the product, or cause

harm to the operator.

Important installation or configuration information. The product may not function correctly if this information is not used.

Useful information.

1

Intimidator Free Spot 60 ILS User Manual Rev. 2

Before You Begin
Safety Notes
ALWAYS: · Connect to a grounded circuit. · Connect to operating voltages as specified on the product’s spec sticker. · Disconnect from power before replacing the fuse. · Disconnect from its power source during periods of inactivity. · Use a safety cable when suspending overhead. · Heed all restrictions and warnings on the spec sticker. · Mount in a location with at least 20 in (50 cm) of ventilation. · Replace the fuse with the same type and rating.
In the event of a serious operating problem, stop using immediately. DO NOT:
· Open this product or attempt any repairs. It contains no user-serviceable parts. · Look at the light source when the product is on. · Use if the power cord is crimped or damaged. · Disconnect by pulling on the power cord. · Allow flammable materials close to the product when it is operating. · Touch the housing when it is on. · Block any ventilation holes/slots in the housing. · Connect to a dimmer or rheostat. · Carry the product by its power cord. · Operate in temperatures higher than 104°F (40°C). · Expose to environments that exceed the Ingress Protection (IP) rating. · Expose to rain or moisture. · Use outdoors. · Submerge. · Expose to corrosive environmental conditions such as temperature, humidity, salinity,
pressure, radiation, or shock. · Set this product on a flammable surface.
Battery Charge Notes
Rechargeable lithium-ion batteries are potentially hazardous and can present a serious FIRE HAZARD, SERIOUS INJURY and/or PROPERTY DAMAGE if damaged, defective, or improperly used.
ALWAYS: Charge using a manufacturer-provided charger while the product is powered off. Charge the battery in temperatures between 32°­95°F (0°­35°C). Allow a depleted battery to charge for a few minutes before turning on the product. If the battery is completely discharged, the device cannot be turned on immediately when the charger is connected. Keep at least 3 ft (1 m) distance to any heat source and away from flammable materials. Keep the lid of any charging case open while charging. Keep batteries away from children. Store batteries between 40­60% charge. Follow local regulations when disposing of batteries. Replace with an authentic Chauvet battery.
DO NOT: Continue charging if the battery becomes hot, smokes, swells, or gives off an odor during charging. Leave the product unattended while charging. Deplete the battery below 10%. Charge the battery in a closed container. Charge for more than 24 hours.

Intimidator Free Spot 60 ILS User Manual Rev. 2

2

Before You Begin
FCC Statement of Compliance
This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected. · Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
RF Exposure Warning for North America and Australia
Warning! This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the user. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Disclaimer
Chauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest version from www.chauvetdj.com. The works of authorship contained in this manual, including, but not limited to, all designs, text, and images are owned by Chauvet. © Copyright 2023 Chauvet & Sons, LLC. All rights reserved. Electronically published by Chauvet in the United States of America. Chauvet, the Chauvet logo, and Intimidator Free Spot 60 ILS are registered trademarks or trademarks of Chauvet & Sons LLC. (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
Keep this User Manual for future use.

3

Intimidator Free Spot 60 ILS User Manual Rev. 2

Introduction
2. Introduction
Product Overview

USB slot
Fuse holder

Carry handle Display screen

Menu buttons

DMX in/out

Safety loop

Power in

Intimidator Free Spot 60 ILS User Manual Rev. 2

4

Product Dimensions
15.4 in 391 mm

Introduction

11.4 in 290 mm

11.9 in 301 mm
10.2 in 258 mm

5

Intimidator Free Spot 60 ILS User Manual Rev. 2

Setup

3. Setup

AC Power
The Intimidator Free Spot 60 ILS has an auto-ranging power supply, and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.

· Always connect the product to a protected circuit (a circuit breaker or fuse). Make

sure the product has an appropriate electrical ground to avoid the risk of

!

electrocution or fire.

· To eliminate unnecessary wear and improve its lifespan, completely disconnect the

product from power via breaker or by unplugging it during periods of non-use.

Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

Fuse Replacement
1. Disconnect the product from power. 2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder. 3. Pry the fuse holder out of the housing. 4. Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating. 5. Insert the fuse holder back in place and reconnect power.
Installed fuse
(held by plastic clip)

Spare fuse holder
(inside safety cap)

Safety cap

!

· Disconnect the product from the power outlet before replacing the fuse. · Always replace a blown fuse with one of the same type and rating.

Battery Power
The Intimidator Free Spot 60 ILS comes with a rechargeable lithium battery for cable-free operation.
Charging the Battery
The battery charges whenever the Intimidator Free Spot 60 ILS is plugged into a power source using the included power cable. If the product is plugged in and not in operation, make sure the product is turned off.
· Before charging the product, read and follow the safety recommendations in the Safety Notes.
· The LED indicator light will flash if units are overcharged. · DO NOT use the Intimidator Free Spot 60 ILS on full power mode while being
charged/plugged into a power source, as the unit will get extremely hot.
Battery Life Indicator
The numbers displayed on the battery indicator show how much battery life remains available. The battery indicator will display up to four (+) signs while charging.

100

Battery Run Time

In use
Maximum Run Time Up to 8 hours

Charging
Recharge Time 6.75 hours

Intimidator Free Spot 60 ILS User Manual Rev. 2

6

Setup
Mounting
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.
Orientation
The Intimidator Free Spot 60 ILS may be mounted in any position; however, make sure adequate ventilation is provided around the product.
Rigging
· Before deciding on a location for the product, always make sure there is easy access to the product for maintenance and programming purposes.
· Make sure adequate ventilation is provided around the product. · Mount the product on a structure or surface that can support the product’s weight (see the Technical
Specifications for weight information). · Always use a safety cable when mounting the product overhead. Mount the product securely to a
rigging point (e.g., an elevated platform or a truss). · Use a mounting clamp of appropriate weight capacity when rigging the product onto a truss.
Mounting Diagram
Mounting clamp
(such as CLP-15 or CLP-15N from Chauvet)

Omega bracket

Safety cable
(such as CH-05 from Chauvet)

7

Intimidator Free Spot 60 ILS User Manual Rev. 2

Operation

4. Operation

Control Panel Operation
To access the control panel functions, use the four buttons located next to the display. Please refer to the Introduction to see the button locations on the control panel.

Button Function

Exits from the current menu or function

Navigates upwards through the menu list and increases the numeric value when in a function Navigates downwards through the menu list and decreases the numeric value when in a function Enables the currently displayed menu or sets the currently selected value into the selected function Menu Map

Refer to the Intimidator Free Spot 60 ILS product page on www.chauvetdj.com for the latest menu map.

Main Menu DMX Address
Run Mode
Setup

Programming Levels

Description

001­499

Selects DMX starting address

08CH

8-channel DMX mode

DMX

10CH

10-channel DMX mode

14Ch

14-channel DMX mode

Slave

Slave 1­4

Sets which slave unit(s) will mimic the master unit

ILS

ILS1­4

Sets ILS mode

AUTO

Sets the fixture to Auto mode

Sound

Sets the fixture to Sound mode

RF

Sets the fixture to connect via RF

Pan

Adjusts the pan angle

Tilt

Adjusts the tilt angle

Color

Selects the color manually

Gobo

Selects the gobo manually

Manual

Gobo Rototate

000­255 Adjusts gobo rotation

Prism

Adjusts prism

Focus

Adjusts focus

Dimmer

Adjusts the brightness

Shutter

Adjusts the shutter

RX

Sets the product to receive D-Fi signal

DFI

TX

Sets the product to transmit D-Fi signal

OFF

Disables D-Fi mode

D-Fi Channel

1­16

Sets D-Fi channel

Pan Reverse

OFF ON

Normal pan operation Reverse pan operation

Tilt Reverse

OFF ON

Normal tilt operation Reverse tilt operation

Screen Reverse

OFF ON

Normal display Reverse display

540

Selects the 540° pan angle range

Pan Angle

360

Selects the 360° pan angle range

180

Selects the 180° pan angle range

234

Selects the 234° tilt angle range

Tilt Angle

180

Selects the 180° tilt angle range

90

Selects the 90° tilt angle range

OFF

Does not restrict the pan and tilt motion

Totem Mode

UP

Restricts the pan and tilt motion for overhead mounting

DOWN

Restricts the pan and tilt motion for surface/ floor mounting

Sensitivity

000­100

Sets the sound sensitivity in Sound mode

Intimidator Free Spot 60 ILS User Manual Rev. 2

8

Operation

Main Menu Setup

Programming Levels
Hold Black

DMX Loss

Auto

Indicator Flash if DMX
Runtime

Sound ON OFF ON
OFF 4 Hours 6 Hours 8 Hours Common

RF

Bind

RF Group

Off Group1­4

RF Bind

Sys Info

Follow Spot
Reset
Factory Reset
Ver: Running
Mode: DMX Address: Temperature:
DFI:


OFF ON NO YES NO YES V _


°C


Description
Holds the last setting when DMX signal is lost Blacks out the fixture when DMX signal is lost Sets the fixture to Auto mode when DMX signal is lost Sets the fixture to Sound mode when DMX signal is lost Enables LED indicator Disables LED indicator The LED indicator flashes when the unit is connected to the DMX The LED indicator flashes when the unit is disconnected from the DMX
Adjusts the light and power consumption based on the amount of time the fixture has been running
Enables control of the fixture using any RF remote Enables control of the Intimidator Free Spot 60 ILS using only the RF remote paired to the fixture Disables RF connection Sets which group of fixture the RF remote will control Link the fixture to a single remote and displays the ID of the linked remote. Press then hold and press . The display will show “SUCCESS” (success) or “ERROR” (failure). Disables Follow Spot mode Enables fixture to be controlled via ILS command
Resets individual functions or all functions from startup
Resets settings to factory default
Displays the firmware version
Displays the current running mode
Displays the DMX address Displays the LED PCB temperature in °C Displays the D-Fi status

DMX Configuration
The Intimidator Free Spot 60 ILS works with a DMX controller. Information about DMX is in the Chauvet DMX Primer available from the Chauvet website: www.chauvetdj.com.

DMX Personality and Starting Address
When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses. Choosing a starting address that is too high could restrict access to some of the product’s channels. The Intimidator Free Spot 60 ILS uses up to 14 DMX channels in a 14CH DMX mode, which defines the highest configurable address to 499. For more information about the DMX protocol, download the DMX Primer from: www.chauvetdj.com. To select the starting address, do the following:
1. Press

repeatedly until DMX Address shows on the display. 2. Press

. 3. Use or to select the starting address, from 001­499. 4. Press .

9

Intimidator Free Spot 60 ILS User Manual Rev. 2

Operation Gobos

1

2

3

4

5

67

DMX Values
08CH 10CH 14CH Function 1 1 1 Pan ­ ­ 2 Fine pan 2 2 3 Tilt ­ ­ 4 Fine tilt ­ ­ 5 Pan/tilt speed
3 3 6 Color wheel

4

4

7

Gobo wheel (see Gobos)

5 5 8 Gobo rotation

Value Percent/Setting
000 255 0­540° 000 255 Fine control of panning 000 255 0­234° 000 255 Fine control of tilting 000 255 Pan/tilt speed, fast to slow 000 006 White 007 013 Red 014 020 Orange 021 027 Yellow 028 034 Green 035 041 Blue 042 048 CTO 049 055 Cyan 056 062 Magenta 063 189 Color indexing 190 221 Color clockwise rotation, fast to slow 222 223 Stop 224 255 Color counter-clockwise rotation, slow to fast 000 007 Open 008 015 Gobo 1 016 023 Gobo 2 024 031 Gobo 3 032 039 Gobo 4 040 047 Gobo 5 048 055 Gobo 6 056 063 Gobo 7 064 071 Gobo 7 shake, slow to fast 072 079 Gobo 6 shake, slow to fast 080 087 Gobo 5 shake, slow to fast 088 095 Gobo 4 shake, slow to fast 096 103 Gobo 3 shake, slow to fast 104 111 Gobo 2 shake, slow to fast 112 119 Gobo 1 shake, slow to fast 120 127 Open 128 189 Gobo clockwise rotation, slow to fast 190 193 Stop 194 255 Gobo counter- clockwise rotation, slow to fast 000 007 No function 008 119 Gobo rotation, clockwise, slow to fast 120 231 Gobo rotation, counterclockwise, slow to fast 232 255 Gobo bounce, short to long

Intimidator Free Spot 60 ILS User Manual Rev. 2

10

Operation

08CH 10CH 14CH Function 6 6 9 Prism 7 7 10 Focus ­ 8 11 Dimmer 8 9 12 Shutter
­ 10 13 Function
­ ­ 14 Movement macro

Value Percent/Setting
000 015 No function 016 255 3-facet prism 000 255 Focus, large to small 000 255 0­100% 000 003 Closed 004 007 Open 008 076 Strobe, slow to fast 077 145 Pulse strobe, slow to fast 146 215 Random strobe, slow to fast 216 255 Open 000 007 No function 008 015 Blackout on pan/tilt movement 016 023 Blackout on color wheel movement 024 031 Blackout on gobo wheel movement 056 095 No function 096 103 Pan reset 104 111 Tilt reset 112 119 Color wheel reset 120 127 Gobo wheel reset 128 135 No function 136 143 Prism reset 144 151 Focus reset 152 159 Reset all 160 167 No function 168 175 Run time from display menu setting 176 183 Runtime 4-hour mode 184 192 Runtime 6-hour mode 193 200 Runtime 8-hour mode 201 255 No function 000 007 No function 008 023 Movement macro 1 024 039 Movement macro 2 040 055 Movement macro 3 056 071 Movement macro 4 072 087 Movement macro 5 088 103 Movement macro 6 104 119 Movement macro 7 120 135 Movement macro 8 136 151 Sound-active macro 1 152 167 Sound- active macro 2 168 183 Sound-active macro 3 184 199 Sound-active macro 4 200 215 Sound-active macro 5 216 231 Sound-active macro 6 232 247 Sound-active macro 7 248 255 Sound-active macro 8

11

Intimidator Free Spot 60 ILS User Manual Rev. 2

Operation
Standalone Configuration
Set the product in one of the standalone modes to control without a DMX controller.
Never connect a product that is operating in any standalone mode to a DMX string connected to a DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller.
Run Mode
Automatic mode
To run the Intimidator Free Spot 60 ILS in automatic mode, follow the instructions below: 1. Press

repeatedly until Run Mode is displayed. 2. Press . 3. Use or to select Auto. 4. Press .
Sound-active mode
To run the Intimidator Free Spot 60 ILS in sound mode, do the following: 1. Press repeatedly until Run Mode is displayed. 2. Press . 3. Use

or to select Sound. 4. Press . RF mode To use the Intimidator Free Spot 60 ILS with an RFC or RFC-XL remote, it must first be set to RF mode. To do this, follow the instructions below: 1\. Press repeatedly until Run Mode is displayed. 2. Press . 3. Use or to select RF. 4\. Press . For more information about using the Intimidator Free Spot 60 ILS with an RF remote, see RFC Remote Control section. Manual Mode To operate the Intimidator Free Spot 60 ILS manually through the menu, do the following: 1. Press repeatedly until Run Mode is displayed. 2. Press . 3. Use or to select Manual. 4. Press . 5. Use or to select from Pan, Tilt, Color, Gobo, Gobo Rotate, Prism, Focus, Dimmer, or Shutter. 6. Press . 7. Use or to increase or decrease the value of the selected function, from 000­255. 8. Press . 9. Repeat steps 6-9 until the product is set as desired.

Intimidator Free Spot 60 ILS User Manual Rev. 2

12

Operation
Settings Configuration
Use a DMX controller to set and control the Intimidator Free Spot 60 ILS.
D-Fi Settings
To access the D-Fi Setting menu on the Intimidator Free Spot 60 ILS, do the following: 1. Press

repeatedly until Setup shows on the display. 2. Press . 3. Use or to select DFI (to activate D-Fi mode) or DFI Channel (to set the D-Fi channel). 4. Press .
To set which D-Fi mode the Intimidator Free Spot 60 ILS will follow, follow the instructions below: 1. Select the DFI option. 2. Use or to select RX (to set the product to receive D-Fi signal), TX (to set the product to transmit D-Fi signal), or OFF (to deactivate D-Fi mode). 3. Press .
To set the D-Fi channel on the Intimidator Free Spot 60 ILS, do the following:

  1. Select the DFI Channel option. 2. Use or to set the D-Fi channel, from 1­16. 3. Press .
    Pan Reverse
    To manually set the orientation of the pan on the Intimidator Free Spot 60 ILS, follow the instructions below: 1. Press repeatedly until Setup shows on the display. 2. Press . 3. Use or to select Pan Reverse. 4. Press . 5. Use or to select OFF (normal pan motion) or ON (reversed pan motion). 6. Press .
    Tilt Reverse
    To manually set the orientation of the tilt on the Intimidator Free Spot 60 ILS, do the following: 1. Press repeatedly until Setup shows on the display. 2. Press . 3. Use or to select Tilt Reverse. 4. Press . 5. Use or to select OFF (normal tilt motion) or ON (reversed tilt motion). 6. Press .
    Screen Reverse
    To manually set the orientation of the tilt on the Intimidator Free Spot 60 ILS, do the following: 1. Press repeatedly until Setup shows on the display. 2. Press . 3. Use or to select Screen Reverse. 4. Press . 5. Use or to select OFF (normal screen display) or ON (reversed screen display). 6. Press .
    Pan Range
    To set the maximum angle of the pan on the Intimidator Free Spot 60 ILS, do the following: 1. Press repeatedly until Setup shows on the display. 2. Press . 3. Use or to select Pan Range. 4. Press . 5. Use or to set the pan angle from 180 (180°), 360 (360°), or up to 540 (540°). 6. Press .
    Tilt Range
    To set the maximum angle of the tilt on the Intimidator Free Spot 60 ILS, follow the instructions below: 1. Press repeatedly until Setup shows on the display. 2. Press . 3. Use or to select Tilt Range. 4. Press . 5. Use or to set the tilt angle from 90 (90°), 180 (180°), or up to 234 (234°). 6. Press .

13

Intimidator Free Spot 60 ILS User Manual Rev. 2

Operation
Totem Mode
To restrict the range of pan and tilt motion based on how the Intimidator Free Spot 60 ILS is mounted, do the following:
1. Press

repeatedly until Setup is displayed. 2. Press . 3. Use

or to select Totem Mode. 4. Press . 5. Use or to select from OFF (no restriction on the pan and tilt motion), UP (restricts the pan and tilt motion for overhead mounting), or DOWN (restricts the pan and tilt motion for surface or floor mounting). 6. Press . Sound Sensitivity To set the sound sensitivity on the Intimidator Free Spot 60 ILS, follow the instructions below: 1. Press repeatedly until Setup is displayed. 2. Press . 3. Use or to select Sensitivity. 4. Press . 5. Use or to increase or decrease the sound sensitivity, from 000­100. 6. Press . DMX Loss To set the action that the Intimidator Free Spot 60 ILS will do when the DMX signal is lost, do the following: 1. Press repeatedly until Setup is displayed. 2. Press . 3. Use or to select DMX Loss. 4. Press . 5. Use or to select from Hold (holds the last setting when DMX signal is lost), Black (blacks out the fixture when DMX signal is lost), Auto (sets the fixture to Auto mode when DMX signal is lost), or Sound (sets the fixture to Sound mode when DMX signal is lost). 6. Press . Indicator To enable or disable the LED indicator on the Intimidator Free Spot 60 ILS, follow the instructions below: 1. Press repeatedly until Setup is displayed. 2. Press . 3. Use or to select Indicator. 4. Press . 5. Use or to select from ON (enables the LED indicator) or OFF (disables the LED indicator). 6. Press . Flash if DMX To set whether the LED indicator flashes when the Intimidator Free Spot 60 ILS is connected to or disconnected from the DMX, do the following: 1\. Press repeatedly until Setup is displayed. 2. Press . 3. Use or to select Flash if DMX. 4. Press . 5. Use or to select from ON (the LED indicator flashes when the fixture is connected to the DMX) or OFF (the LED indicator flashes when the fixture is disconnected to the DMX). 6. Press . Run Time To adjust the run time on the Intimidator Free Spot 60 ILS, follow the instructions below: 1\. Press repeatedly until Setup is displayed. 2. Press . 3. Use or to select Runtime. 4. Press . 5. Use or to select the number of hours the fixture will run: 4 Hours, 6 Hours, or 8 Hours. 6\. Press . The maximum output is inversely proportional to the run time: The brighter the output, the less run time available.

Intimidator Free Spot 60 ILS User Manual Rev. 2

14

Operation
RF Setting
To set how the Intimidator Free Spot 60 ILS will receive RF signal and work with RF remotes, do the following: 1. Press

repeatedly until Setup is displayed. 2. Press . 3. Use or to select RF. 4. Press

. 5. Use or to select from the following: Common (to allow the fixture to respond to all RF signals), Bind (to link the fixture to a single RF remote), or Off (to turn off RF reception). 6. Press . RF Group To select which group of fixtures the RF remote will control, follow the instructions below: 1. Press repeatedly until Setup is displayed. 2. Press . 3. Use or to select RF Group. 4. Press . 5. Use or to select Group 1­4. 6. Press . Follow Spot To enable control of the Intimidator Free Spot 60 ILS via ILS command, do the following: 1. Press repeatedly until Setup is displayed. 2. Press . 3. Use or to select Follow Spot. 4. Press . 5. Use or to select ON (enables Follow Spot mode) or OFF (disables Follow Spot mode). 6. Press . Product Reset To reset individual or all functions on the Intimidator Free Spot 60 ILS upon startup, do the following: 1. Press repeatedly until Setup is displayed. 2. Press . 3. Use or to select Reset. 4. Press . 5. Use or to select YES (enables reset of all functions from startup) or NO (disables product reset from startup). 6. Press . Factory Reset To reset the product to factory default settings, follow the instructions below: 1. Press repeatedly until Setup is displayed. 2. Press . 3. Use or to select Factory Reset. 4. Press . 5. Use or to select YES (enables factory reset) or NO (disables factory reset). 6. Press . Product Information To view the product information, do the following: 1. Press repeatedly until Sys Info shows on the display. 2. Press . 3. Use or to choose among: · Ver: displays the current software version of the fixture · Running Mode: displays the current running mode · DMX Address: displays the DMX address · Temperature: displays the LED PCB temperature in °C · DFI: displays the fixture’s D-Fi status

15

Intimidator Free Spot 60 ILS User Manual Rev. 2

Operation
Calibration Menu
To access the calibration menu of the Intimidator Free Spot 60 ILS, do the following: 1. Power on the product. 2. Once the screen displays the CHAUVET DJ logo, press the and buttons simultaneously. · The screen will display “MOTOR SET” above and “Resetting…” below the CHAUVET DJ logo. 3. After about 10 seconds, the screen will show the calibration menu.
ILS Mode
ILS (Integrated Lighting System) provides 4 modes that synchronize with the GigBAR MOVE+ILS: Modes 1 and 3 synchronize with side 1 of the GigBAR MOVE+ILS, whereas modes 2 and 4 synchronize with side 2 of the GigBAR MOVE+ILS. When linked, effects will sync with the most similar effect on the selected side of the GigBAR MOVE+ILS: Kinta effects will sync with one of the kintas, moving heads will sync with one of the moving heads, and wash effects will sync with one of the pars. Laser effects will sync with the laser, and strobe effects will sync with the strobe effects regardless of ILS mode. This product will synchronize with the spot effect on the selected side of the GigBAR MOVE+ILS, as well as the laser and strobes. To set the Intimidator Free Spot 60 ILS to respond to an ILS signal:
1. Press

repeatedly until ILS shows on the display. 2. Use or

to select from ILS1 (side 1), ILS2 (side 2), ILS3 (side 1), or ILS4 (side 2). 3. Press . Master/Slave Mode The Master/Slave mode allows a single Intimidator Free Spot 60 ILS product (the “master”) to control the actions of one or more Intimidator Free Spot 60 ILS products (the “slaves”) without the need of a DMX controller. The master product will be set to operate in Standalone, whereas the slave products will be set to operate in Slave mode. Once set and connected, the slave products will operate in unison with the master product. Configure the products as indicated below. Slave products: 1\. Press repeatedly until Setup shows on the display. Press . 2. Use or to select DFI. Press . 3. Use or to select RX. Press . 4. Press repeatedly until Run Mode shows on the display. Press . 5. Use or to select Slave. Press . 6. Use or to select the slave unit(s), from Slave1­4. Press . 7. Set the DMX address to 001. 8. Set the D-Fi to receive a specific channel, 1­16. 9. Finish setting and connecting all the slave products. Master product: 1. Set the master product to operate in standalone mode. 2\. Set the D-Fi to transmit on the D-Fi channel the slaves are receiving on. · For more information on how to activate the Intimidator Free Spot 60 ILS built-in D-Fi, see D-Fi Settings. · All products must be set to the same DMX personality, DMX address, and D-Fi channel. · Configure all the slave products before configuring the master to transmit. · Never connect a DMX controller to a D-Fi channel configured for Master/Slave operation because the controller may interfere with the signals from the master.

Intimidator Free Spot 60 ILS User Manual Rev. 2

16

Operation

RFC Remote Control
The Intimidator Free Spot 60 ILS can be operated with an RFC remote or an RFC- XL remote (sold separately). To enable RF control, follow the instructions below:
1. Press

repeatedly until Setup shows on the display. 2. Press

. 3. Use or to select RF. 4. Press . 5. Use or to select from the following: Common (to allow the fixture to respond to all RF signals), Bind (to link the fixture to a single RF remote), or Off (to turn off RF reception). 6\. Press . For more information about using an RFC or RFC-XL remote, download the user manuals from www.chauvetdj.com

RFC-XL Remote Control Operation

GROUP

Black OUT

AUTO

FADE

SOUND

SPEED / SENSITIVITY

STROBE DIMMER

RED GREEN BLUE AMBER

WHITE UV PAN TILT

COLOR GOBO PRISM FOCUS

ZOOM

GOBO PRISM ROTATE ROTATE

FREEZE

Automatic Mode Automatic mode will enable you to run the automatic programs on the product. To turn on Automatic mode:
1. Press . 2. Press <+> or <­> to choose between the different auto programs. To adjust the speed of the automatic program: 1. Press <SPEED/SENSITIVITY>. 2. Press <+> or <­> to increase or decrease the speed of the program. Sound-Active Mode To turn on Sound-Active mode: 1. Press . 2. Press <+> or <­> to select a sound-active program. To adjust the sound sensitivity: 1. Press <SPEED/SENSITIVITY>. 2. Press <+> or <­> to increase or decrease the sensitivity. Dimmer To adjust the total output of the product: 1. Press . 2. Press <+> or <­> to increase or decrease the output level. Prism To adjust the focus of the product’s output: 1. Press . 2. Press <+> or <­> to select the prism. Focus To adjust the focus of the product’s output: 1. Press . 2. Press <+> or <­> to adjust the focus. Pan To adjust the product’s pan angle: 1. Press . 2. Press <+> or <­> to adjust the pan. Tilt To adjust the product’s tilt angle: 1. Press . 2. Press <+> or <­> to adjust the tilt. Black Out To black out the lights of the product: 1. Press . This will turn off all the lights until the button is
pressed again.

The RFC-XL remote will not respond to any inputs when Black Out is activated. If the remote does not respond when a button is pressed, try pressing <BLACK OUT>. You may have inadvertently activated Black Out.

17

Intimidator Free Spot 60 ILS User Manual Rev. 2

Maintenance
5. Maintenance
Product Maintenance
Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean all lighting products at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency. To clean the product, follow the instructions below:
1. Unplug the product from power. 2. Wait until the product is at room temperature. 3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external
surface/vents. 4. Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl
alcohol. 5. Apply the solution directly to a soft, lint-free cotton cloth or a lens-cleaning tissue. 6. Softly drag any dirt or grime to the outside of the transparent surface. 7. Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.

Intimidator Free Spot 60 ILS User Manual Rev. 2

18

Technical Specifications

6. Technical Specifications

Dimensions and Weight

Length 11.4 in (290 mm)

Width 11.9 in (301 mm)

Height 15.4 in (391 mm)

Note: Dimensions in inches rounded to the nearest hundredth.
Power

Power Supply Type Switching (internal)

Range 100 to 240 VAC, 50/60 Hz

Weight 22 lb (9.9 kg)
Voltage Selection Auto-ranging

Parameter Consumption Operating Current
Fuse

120 V, 60 Hz 110 W 0.9 A
T 2 A, 250 V

230 V, 50 Hz 107 W 0.5 A
T 2 A, 250 V

Power I/O Power cord plug

U.S./Worldwide Edison (U.S.)

UK/Europe Local plug

Light Source

Type LED

Quantity 1

Color Cool white

Power 60 W

Current 4.8 A

Lifespan 50,000 hours

Photometrics

Strobe Rate 0 to 23 Hz

Zoom Range 13°­19°

Illuminance @ 2 m (13°) Illuminance @ 2 m (19°)

16,932 lux

9,424 lux

Thermal

Maximum External Temperature 104 °F (40 °C)

Cooling System Convection

DMX

Input/Output 3-pin XLR

Channel Range 8, 10, or 14

Ordering

Product Name Intimidator Free Spot 60 ILS

Item Code 10012030

UPC Number
781462223786

19

Intimidator Free Spot 60 ILS User Manual Rev. 2

Contact Us

Contact Us

General Information Chauvet World Headquarters
Address: 3360 Davie Rd. Davie, FL 33314
Voice: 954-577-4455 Fax: 954-929-5560
Toll Free: 800-762-1084 Chauvet U.K.
Address: Pod 1 EVO Park Little Oak Drive, Sherwood Park,
Nottinghamshire, NG15 0EB UK
Voice: +44 (0) 1773 511115 Fax: +44 (0) 1773 511110
Chauvet Benelux Address: Stokstraat 18 9770 Kruishoutem Belgium Voice: +32 9 388 93 97
Chauvet France Address: 3, Rue Ampère 91380 Chilly-Mazarin France Voice: +33 1 78 85 33 59
Chauvet Germany Address: Bruno-Bürgel-Str. 11 28759 Bremen Germany Voice: +49 421 62 60 20
Chauvet Mexico Address: Av. de las Partidas 34 – 3B (Entrance by Calle 2) Zona Industrial Lerma Lerma, Edo. de México, CP 52000 Voice: +52 728-690-2010

Technical Support Voice: 844-393-7575 Fax: 954-756-8015
Email: chauvetcs@chauvetlighting.com Website: www.chauvetprofessional.com
Email: UKtech@chauvetlighting.eu Website: www.chauvetprofessional.eu
Email: BNLtech@chauvetlighting.eu Website: www.chauvetprofessional.eu
Email: FRtech@chauvetlighting.fr Website: www.chauvetprofessional.eu
Email: DEtech@chauvetlighting.de Website: www.chauvetprofessional.eu
Email: servicio@chauvet.com.mx Website: www.chauvetprofessional.mx

Warranty & Returns
For warranty terms and conditions and return information, please visit our website. For customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration. For customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu/warranty-registration.

Intimidator Free Spot 60 ILS User Manual Rev. 2

20

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Chauvet DJ User Manuals

Related Manuals