PARMIDA PLED-DNSQ49W5CCTDIM LED Square Recessed Ceiling Slim Panel Light Installation Guide

June 15, 2024
PARMIDA

INSTALLATION GUIDE
LED ULTRA-THIN CEILING LIGHT – 5CCT – SQUARE
WITH JUNCTION BOX
PLED-DNSQ49W5CCTDIM
PLED-DNSQ612W5CCTDIM

PLED-DNSQ49W5CCTDIM LED Square Recessed Ceiling Slim Panel Light

IMPORTANT: Please read carefully and save these instructions, as you may need them at a later date. When using electrical equipment, basic safety precautions should always be followed as below:

  1. Before beginning installation, ensure power is turned off at the main breaker.
  2. Ensure your eyes are properly protected

GENERAL: All electrical connections must be in accordance with local and National Electric Code (NEC) standards. All electrical connections, installation and service should be performed by a qualified licensed electrician.
READ AND FOLLOW BELOW SAFETY INSTRUCTIONS
To prevent wiring damage or abrasion do not expose wiring to edges of sheet metal or other sharp objects.
Supply conductors (power wires) connecting the LED light must be rated minimum 90˚C. If uncertain consult an electrician.
Type IC Rated for direct contact with insulation.
This LED light is dimmable. Please refer to our website for the most up-to- date compatible dimmer list.
REQUIRED TOOLS: (not included) Safety glasses and gloves, tape measure, saw, pencil/pen.
UNPACKING: Thoroughly inspect the LED light for freight damage. Freight damage should be reported to the delivery carrier.

SELECTING COLOR TEMPERATURE

To avoid risk of damage, ensure wall switch connected to the LED light is turned to off position before changing or selecting desired color temperature (CCT) on the selector switch. Select the color temperature via the CCT switch located on the junction box. Using the color (CCT) selector switch, select the desired color temperature (2700K Warm White, 3000K Soft White, 3500K Neutral White, 4000K Cool White, or 5000K Day Light).

COMPATIBLE DIMMER LIST

DIMMING
Dimming performance may depend on the dimmer, the dimmer range adjustment setting (for dimmers with brightness range adjustments), the wiring method, and/or the number of LED modules installed onto the dimmer circuit.
For dimmer selection, Dimming Control Manufacturers revise their product often; for the latest list of compatible dimmers please visit our website.
Please follow the Dimming Control Manufacturer’s instructions for the installation of all dimming controls.
NOTE: The table shows dimmers that have been tested and have demonstrated proper operation under normal conditions.
The absence of a dimmer from this chart does not necessarily imply incompatibility.
Please visit our website www.parmida.com or contact our customer support team for more details.

LUTRON LEVITON
AYCL-153P 6674
CLDVSL-153P-WH 6681
CT600P 1G44I1
CTCL-153P 1PL06
DV600P 6672-1LW
DVCL-153P 6672-DECORA
IPL06 DSL06
MACL-153M DSM10-DECORA
PD-6WCL
S600-P
SCL153P
TG-10P
TG600P
TGCL-153P

STEPS FOR INSTALLATION

  1. RETROFIT: If there is an existing hole, make sure that it is the correct size (4.3in/108mm for 4″ model & 6.2in/158mm for 6″ model) for the LED light to properly fit. If applicable, remove any existing retrofit can.
  2. NEW INSTALLATION: If there is no existing hole, cut a new hole using the provided hole template. Place template over the desired location. Trace the outer ring with a pen or pencil (not included). Cut the opening with a saw (not included).
  3. Open the cover of the remote driver box. Push and remove one of the knockouts on the side plate.
  4. Locate power supply leads from remote driver box and connect to power source using wire nuts (provided).
  5. Connect black wire to live wire, white wire to neutral wire, and green wire with ground (as shown) and secure using wire nuts. Close the cover of the box.
  6. Connect the remote driver box to the LED light and tighten the nut connector by hand.
  7. Place remote driver box through the cut-out hole. If remote driver box needs to be attached, use provided keyhole fittings on the back of the box to hang it using round head screws (not included).
  8. Pull the spring clips on the LED light up and through the ceiling hole and place LED light in the hole making sure the spring clips are holding securely.
  9. Turn the power back on. If the LED light doesn’t illuminate within 5 seconds, turn power off, carefully remove the LED light and double check all wiring.

PARMIDA PLED-DNSQ49W5CCTDIM LED Square Recessed Ceiling Slim Panel Light -
STEPS FOR INSTALLATION

WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DISCONNECT MAIN POWER AT FUSE OR CIRCUIT BREAKER BEFORE INSTALLING OR SERVICING THE LED LIGHT
DO NOT PLACE YOUR HAND UNDERNEATH SPRING CLIPS DURING REMOVAL PROCESS. SNAPPING OF THE CLIPS CAN CAUSE INJURIES TO THE HAND.
DO NOT USE ANY OTHER DRIVER EXCEPT PARMIDA LIGHTING DRIVER THAT IS INCLUDED WITH THE LED LIGHT.

info@parmida.com
www.parmida.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

PARMIDA User Manuals

Related Manuals