MITSUBISHI ELECTRIC PLA-A24EA8 BTU Commercial Ceiling Cassette Single Zone Heat Pump Owner’s Manual
- June 15, 2024
- Mitsubishi Electric
Table of Contents
MITSUBISHI ELECTRIC PLA-A24EA8 BTU Commercial Ceiling Cassette Single
Zone Heat Pump
Product Information
Specifications
- Job Name: System Reference: PLA-A24EA8 & PUY-A24NHA7 24,000 BTU/H 3′ X 3′ CEILING CASSETTE 24,000 BTU/H COOLING ONLY OUTDOOR
- Indoor Unit: PLA-A24EA8
- Outdoor Unit: PUY-A24NHA7 Date
Indoor Unit Specifications
- Operating Temperature Range: Indoor Unit
- Cooling Intake Air Temp [Maximum / Minimum]: 94.3°F / 94.3°F
- Fan Motor Full Load Amperage: 0.86 A
- Fan Motor Output Airflow Rate [Cooling / Heating]: 1940 CFM
- Sound Pressure Level, Cooling: 47 dB(A)
- Compressor Type: INVERTER-driven twin rotary
- Compressor Model: SNB172FWHM1
- Compressor Rated Load Amps: 7 A
- Compressor Locked Rotor Amps: 11 A
- External Finish Color: Ivory Munsell 3Y 7.8/1.1
- Unit Dimensions: 37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x 330 (+30) x 943]
- Unit Weight: 151 Lbs. [68 kg]
Outdoor Unit Specifications
- Operating Temperature Range: Outdoor Unit
- Refrigerant: R410A
- Cooling Air Temp [Maximum / Minimum]: 115°F / -40°F
- Pre-Charged Refrigerant Amount: 7.0 oz.
- Maximum Pre-Charged Piping Length: 11.0 Ft. [3.35 m]
- Type: LEV Reverse Cycle
- Base Pan Heater: Yes
- Package Dimensions: 40-15/16 x 17-11/16 x 40-11/16 [1040 x 450 x 1033]
- Package Weight: 176 Lbs. [80 kg]
Piping Specifications
- Gas Pipe Size O.D. [Flared]: 5/8 [15.88] In.[mm]
- Liquid Pipe Size O.D. [Flared]: 3/8 [9.52] In.[mm]
- Maximum Piping Length: 225 Ft. [68 m]
- Maximum Height Difference: 100 Ft. [30 m]
- Maximum Number of Bends: 15
Indoor Unit Accessories
- Control Interface: Remote Sensor Wired Remote Controller
- NOTE: PAC-SF40RM-E (Unable to use with wireless remote controller)
Outdoor Unit Accessories
- PAC-SG59SG-E
- PAC-SG63DP-E
- PAC-SG64DP-E
- PAC-SK52ST
- M21EC0397
- PAC-USCMS-MN-1
- M21EC1397
- HG-A6
- PAC-SJ85MA-E
- PAC-SJ95MA-E
- S144-250
- S144-50
- S164-250
- S164-50
- ULTRILITE2
- QSMS1801M
- QSMS2401M
- QSWB2000M-1
- QSWBSS
- QSMS1201M
- WB-PA5
- WB-RE5
- WB-SD5
Product Usage Instructions
Installation
- Choose a suitable location for mounting the indoor unit. Ensure proper clearance for air intake and discharge.
- Install the outdoor unit in a well-ventilated area, away from direct sunlight and obstacles.
- Connect the indoor and outdoor units using the specified gas and liquid pipes.
- Install the control interface and accessories as needed.
- Refer to the user manual for detailed installation instructions.
Operation
- Ensure the power supply is connected and turned on.
- Use the wired remote controller or control interface to set the desired temperature and mode.
- The unit will start cooling or heating according to the set temperature and mode.
- Adjust the fan speed and airflow direction as needed.
- To turn off the unit, set the temperature to a higher value or use the power button on the remote controller.
Maintenance
- Regularly clean the air filters to ensure optimal performance.
- Inspect the outdoor unit for any debris or obstructions and clean if necessary.
- Check the refrigerant levels and refill if required.
- Schedule professional maintenance at least once a year.
Frequently Asked Questions (FAQ)
Q: Can I use a wireless remote controller with the PLA-A24EA8 indoor unit?
A: No, the PLA-A24EA8 is only compatible with the wired remote controller (PAC-SF40RM-E).
INDOOR UNIT FEATURES
- Space-efficient ductless installation
- Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
- Airflow settings for high and low ceiling applications
- Individual vane settings for direct/indirect airflow control or variable airflow patterns
- Knockouts for outside-air intake and branch-duct run
- Filter indicator signal
- Easy-to-clean, washable filter (optional high-efficiency filter available – requires multi-function casement)
- Built-in condensate lift mechanism
- Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
- Multiple control options available:
- Kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
OUTDOOR UNIT FEATURES
- Variable speed INVERTER-driven compressor
- Pre-charged with refrigerant volume for piping length up to 70 ft
- Low ambient cooling down to -40°F providing 100% capacity (with wind baffles)
- 24-hour continuous operation (cooling mode)
- High-pressure protection
- Fast restart
- Superior energy and operational efficiency
- Seacoast protection
- External Outer Panel : Phosphate coating + Acrylic-Enamel coating
- Fan Motor Support: Epoxy resin coating (at edge face)
- Separator Assembly Valve Bed: Epoxy resin coating (at edge face)
- Blue Fin treatment is an anti-corrosion treatment that is applied to the Heat exchanger coil to protect it against airborne contaminants.
- Heat exchanger coil and base panel rated for 2,000 hours per ASTM B117 testing
- Seacoast protection standard from 2022 production
SPECIFICATIONS
PLA-A24EA8 & PUY-A24NHA7
Cooling at 95°F1 | Maximum Capacity | BTU/H | 24,000 |
---|---|---|---|
Rated Capacity | BTU/H | 24,000 | |
Minimum Capacity | BTU/H | 10,000 | |
Maximum Power Input | W | 1,670 | |
Rated Power Input | W | 1,670 | |
Moisture Removal | Pints/h | 3.0 | |
Sensible Heat Factor | 0.86 | ||
Power Factor [208V / 230V] | % | 94.3 / 94.3 | |
Efficiency | SEER2 | 24.7 | |
EER21 | 14.3 | ||
HSPF2 [IV] | — | ||
ENERGY STAR® Certified | Yes | ||
Electrical | Voltage, Phase, Frequency | 208/230, 1, 60 | |
Guaranteed Voltage Range | V AC | 198 – 253 | |
Voltage: Indoor – Outdoor, S1-S2 | V AC | 208/230 | |
Voltage: Indoor – Outdoor, S2-S3 | V DC | 24 | |
Short-circuit Current Rating [SCCR] | kA | 5 | |
Recommended Fuse/Breaker Size (Outdoor) | A | 25 | |
Recommended Wire Size [Indoor – Outdoor] | AWG | 14 | |
Power Supply | The indoor unit is powered by the outdoor unit | ||
Indoor Unit | MCA | A | 1.0 |
Fan Motor Full Load Amperage | A | 0.56 | |
Fan Motor Type | DC Motor | ||
Airflow Rate at Cooling, Dry | CFM | 530–640–710–810 | |
Airflow Rate at Cooling, Wet | CFM | 490–600–670–770 | |
Sound Pressure Level [Cooling] | dB[A] | 28–30–33–36 | |
Drain Pipe Size | In. [mm] | 1-1/4 [32] | |
Condensate Lift Mechanism, Maximum Distance | In. [mm] | 33-7/16 [850] | |
Coating on Heat Exchanger | — | ||
External Finish Color | White Munsell 6.4Y 8.9/0.4 | ||
Unit Dimensions | W x D x H: In. [mm] | 33-1/16 x 33-1/16 x 11-3/4 [840 x 840 x |
298]
Package Dimensions| W x D x H: In. [mm]| 34-19/64 x 35-35/64 x 16-37/64 [871 x
903 x 421]
Unit Weight| Lbs. [kg]| 57 [26]
Package Weight| Lbs. [kg]| 89 [40]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum /
Minimum]*| °F| 90 DB, 72 WB / 66 DB, 61 WB
Outdoor Unit| MCA| A| 19.0
MOCP| A| 26
Fan Motor Full Load Amperage| A| 0.4
Fan Motor Output| W| 86
Airflow Rate [Cooling / Heating]| CFM| 1940
Refrigerant Control| LEV
Defrost Method| Reverse Cycle
Coating on Heat Exchanger| Blue Fin Coating**
Sound Pressure Level, Cooling1| dB(A)| 47
Compressor Type| INVERTER-driven twin rotary
Compressor Model| SNB172FWHM1
Compressor Rated Load Amps| A| 7
Compressor Rotor Amps| A| 11.0
Compressor Oil [Type // Charge]| oz.| FV50S // 23
External Finish Color| Ivory Munsell 3Y 7.8/1.1
Base Pan Heater| N/A
Unit Dimensions| W x D x H: In. [mm]| 37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x
330 (+30) x 943]
Package Dimensions| W x D x H: In. [mm]| 40-15/16 x 17-11/16 x 40-11/16 [1040
x 450 x 1033]
Unit Weight| Lbs. [kg]| 151 [68]
Package Weight| Lbs. [kg]| 176 [80]
Outdoor Unit Operating Temperature Range| Cooling Air Temp [Maximum /
Minimum]| °F| 115 DB / -40 DB
Refrigerant| Type| R410A
Pre-Charged Refrigerant Amount| Lbs, oz| 7.0, 11.0
Maximum Pre-Charged Piping Length| Ft. [m]| 70.0 [20.0]
Additional Refrigerant Charge Per Additional Piping Length| oz./Ft. [g/m]| 0.3
[22.5]
NOTES:
- AHRI Rated Conditions
- (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor)
- F 80 DB, 67 WB // 95 DB, 75 WB
- Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Wind baffles are required to operate below 23°F DB in cooling mode.
- The cooling-only system with advanced wind baffle: -40°F – 115°F.
- Refer to wind baffle documentation for further information.
- Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- The system cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
Blue Fin Coating Standard from 2022 production:
- PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U
- PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU
Piping | Gas Pipe Size O.D. [Flared] | In.[mm] | 5/8 [15.88] |
---|---|---|---|
Liquid Pipe Size O.D. [Flared] | In.[mm] | 3/8 [9.52] | |
Maximum Piping Length | Ft. [m] | 225 [68] | |
Maximum Height Difference | Ft. [m] | 100 [30] | |
Maximum Number of Bends | 15 |
AHRI Rated Conditions
- (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
- Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Wind baffles are required to operate below 23°F DB in cooling mode.
- A cooling-only system with advanced wind baffle: -40°F – 115°F.
- Refer to wind baffle documentation for further information.
- Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- The system cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
- Blue Fin Coating Standard from 2022 production:
- PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U
- PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU
INDOOR UNIT ACCESSORIES
PLA-A24EA8
Control Interface | 3-Pin Connector | □ PAC-715AD |
---|---|---|
Airline ZBS Wired Blueface Principal Controller White | □ AZZBSBLUEFACECB | |
Airline ZBS Wired Blueface Principal Controller White | □ AZZBSBLUEZEROCB | |
Airline ZBS Wired Lite Controller White | □ AZZBSLITECB | |
Airline ZBS Wireless Lite Controller White | □ AZZBSLITERB | |
Airline ZBS Wireless Think Controller White | □ AZZBSTHINKRB | |
CN24 Relay Kit | □ CN24RELAY-KIT-CM3 | |
IT Extender | □ PAC-WHS01IE-E | |
Kumo station® for kumo cloud® | □ PAC-WHS01HC-E | |
Procon BACnet® and Modbus® Interface | □ PAC-UKPRC001-CN-1 | |
Remote Operation Adapter‡ | □ PAC-SF40RM-E | |
Thermostat Interface | □ PAC-US445CN-1 | |
USNAP Adapter | □ PAC-WHS01UP-E | |
Wireless Interface for Kumo cloud® | □ PAC-USWHS002-WF-2 | |
Remote Sensor | Flush Mount Remote Temperature Sensor | □ PAC-USSEN002-FM-1 |
Flush Mount Temperature Sensor | □ PAC-USSEN001-FM-1 | |
Remote Temperature Sensor | □ PAC-SE41TS-E | |
Wireless temperature and humidity sensor for Kumo cloud® | □ PAC-USWHS003-TH-1 | |
Wired Remote Controller | Deluxe Wired MA Remote Controller† | □ PAR-40MAAU |
Simple Ductless Wired Remote Controller | □ PAC-SDW01RC-1 | |
Simple MA Remote Controller† | □ PAC-YT53CRAU-J | |
Touch MA Controller† | □ PAR-CT01MAU-SB | |
Wireless Remote Controller | Kumo touch™ RedLINK™ Wireless Controller | □ MHK2 |
Lockdown bracket for remote controller | □ RCMKP1CB | |
Wireless MA Receiver | □ PAR-FA32MA-W | |
Wireless MA Remote Controller | □ PAR-FL32MA-E | |
Wireless Remote Contoller | □ PAR-SL101A-E | |
Wireless Signal Receiver Panel | □ PAR-SR4LU-E | |
Casement | Multi-function Casement | □ PAC-SJ41TM-E |
Condensate | Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor | |
(208/230V) [recommended] | □ X87-721 | |
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor | □ |
X87-835
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ-
MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| High Efficiency Filter Element**| □ PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor®| □ PLP-41EAEU
Lineset| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)| □
MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-65
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E
Space Panel| Space Panel| □ PAC-SJ38AS-E
- NOTES: PAC-SF40RM-E (Unable to use with wireless remote controller)
OUTDOOR UNIT ACCESSORIES
PUY-A24NHA7
Air Outlet Guide | Air Outlet Guide (1 Piece) | □ PAC-SG59SG-E |
---|
Centralized Drain Pan
| Centralized Drain Pan| □ PAC-SG63DP-E
Drain Pan| □ PAC-SG64DP-E
Control/Service Tool| Control/Service Tool| □ PAC-SK52ST
M- & P-Series Maintenance Tool Cable Set| □ M21EC0397
Maintenance Tool Interface| □ PAC-USCMS-MN-1
USB/UART Conversion Cable (Required for all laptop connections)| □ M21EC1397
Hail Guards| Hail Guard| □ HG-A6
M-NET Converter| M-NET Converter| □ PAC-SJ85MA-E
M-NET Converter| □ PAC-SJ95MA-E
Mini-Split Wire| 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □ S144-250
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □ S144-50
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □ S164-250
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □ S164-50
Mounting Pad| Condensing Unit Mounting Pad: 24” x 42” x 3”| □ ULTRILITE2
Stand| 18” Single Fan Stand| □ QSMS1801M
24” Single Fan Stand| □ QSMS2401M
Condenser Wall Bracket| □ QSWB2000M-1
Condenser Wall Bracket – Stainless Steel Finish| □ QSWBSS
Outdoor Unit Stand — 12” High| □ QSMS1201M
Wind Baffle| Front Wind Baffle| □ WB-PA5
Rear Wind Baffle| □ WB-RE5
Side Advanced Wind Baffle| □ WB-SD5
INDOOR UNIT DIMENSIONS
PLA-A24EA8
OUTDOOR UNIT DIMENSIONS
PUY-A24NHA7
- 1340 Satellite Boulevard Suwanee, GA 30024
- Toll Free:800-433-4822 www.mehvac.com
- FORM# PLA-A24EA8 & PUY-A24NHA7 – 202310
- Specifications are subject to change without notice.
- © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
- Job Name: ——————————–
- System Reference: Date: —————————–
- Indoor Unit PLA-A24EA8 ——————————-
- Outdoor Unit PUY-A24NHA7 —————————————-