DUUX DXHU14 Tag Ultrasonic Humidifier
Specifications
- Product Name : Duux Humidifier DXHU14
- Type: Ultrasonic Humidifier
Product Overview
The Duux Humidifier DXHU14 is designed to provide a comfortable and healthy living environment by enhancing indoor air quality. It features a top cover, water tank with a handle, mood light, ventilation duct, ultrasonic membrane, empty water tank sensor, mist outlet, power/water supply indicator, mist output indicators, power button, mist output button, light button, water tank cap, power cable, and an anti-scale and antibacterial cartridge.
Installation and Use
Note: Please read the instructions and warning
sheet included with the product before use.
Facility
Ensure proper installation by following the recommended distances:
- Top: at least 100cm
- Back: at least 50cm
- Side : at least 50cm
- Front: at least 50cm
Box contents
Product overview
Installation and use
Note: Please take notice of the below instructions and the separately included warning sheet before using the product
Installation
-
Please place it on a horizontal and stable surface, otherwise, the might be a risk of water spilling.
-
Please do not set up in a place where only children are present such as children’s rooms.
It can lead to injury or breakdown if the device is knocked over or climbed on. -
Please do not place anywhere where items
may fall from above. It can lead to ignition or a breakdown. -
Please do not set up near devices that are
not compatible with water such as PCs or smartphones. It can cause ignition or a breakdown. -
Please do not use it in any surroundings that could lead to the water in the water tray or in the device freezing. However, if the water in the water tray or the device is frozen please do not operate the device until the ice has thawed. It can cause ignition or a breakdown.
-
Be aware that high humidity levels may encourage the growth of biological organisms in the environment.
-
Do not permit the area around the humidifier to become wet. If dampness occurs, turn the output of the humidifier down. If the humidifier output volume cannot be turned down, use the humidifier intermittently. Do not
allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
- Never leave water in the reservoir when the appliance is not in use.
- Empty and clean the humidifier before storage. Clean the humidifier before next use.
Warning : Micro-organisms that may be present in the water or in the environment where the appliance is used or stored, can grow in the water reservoir and be blown in the air causing very serious health risks when the water is not renewed and the tank. Renew water every 3 days.
Placement
-
Please place away from walls, windows and furniture.
-
Even when it is placed at a sufficient distance from walls or furniture, if it is used in the same place for a long period of time, it can become dirty with scale. We recommend regular cleaning. Please consult chapter 4 for maintenance instructions.
-
Please avoid places with direct sunlight. There is a risk that the device discolors.
-
If there is interference with TV, radio or other electrical devices, please move the device.
-
When moving the device please move it with the base of the device held securely
-
The device does not have an automatic humidity adjustment feature. Wet floors and condensation can form easily in rooms with lower temperatures or high levels of humidity. We recommend
the use of an external hygrometer to monitor humidity. -
Adjust the level of humidity with the mist button, with adequate consideration of the space the device is located in, and by either raising the room temperature or turning off the device.
Filling the water tank
Note: Please check that the power is off before removing the water tank from the device.
-
Remove the top surface cover. Hold and lift the label on the top cover when removing the top cover.
-
Take out the water tank Caution: Do not tilt the device when raising the water tank. This may lead to spillage of water remaining in the device.
-
Turn the water tank cap counterclockwise and remove it from the water tank.
-
Pour water in the water tank. Note: Do not use aromatherapy in this product. we advise using distilled or mineral water as a water source. When using tap water, there is a risk of bacteria growth and increased scale.
Caution: Do not use hot water. It may deform the shape of a water tank. -
The paws of the water tank cap are attached to fit into the feed-water inlet cuts. Firmly turn it clockwise until it stops.
Caution: Please carefully check that the water tank cap has not been inserted diagonally.
Caution: Please check whether the rubber seal on the water tank cap is properly attached. -
Place back the water tank cap on the device after carefully checking whether the water tank is properly in place and attach the top surface cover. Caution: Be sure to place back the top cover after refilling the tank. The mist will not be efficiently distributed without its top cover.
Connecting the product
-
Put the power plug into a wall outlet. The power/water supply indicator will light red when you connect the power plug to a wall outlet. Caution:
-
Do not plug in the device or pull the plug out of the power supply with wet hands or use the product.
-
Thoroughly dry your hands before you use the device, particularly after pouring water into the water tank.
-
Avoid connecting the device using other plugs, multi-outlets, and extension cords.
-
Do not use it when the power cord is bundled together.
-
Push the power button. The power/water supply indicator will light blue and it will begin to humidify with MIN (minimum) mist output. The bottom light will lid up.
Note: There is insufficient water in the tank if the light on the power/water supply indicator turns from blue to red immediately after powering on in the device. Please remove the water tank and fill it with water (see Chapter 2).
Note: The power/water supply display will flash red when there is not enough water in the water tank while in use. -
Push the power button to turn off the device and pull out the plug after use. Caution: When removing the power plug, be sure to hold it by the plug. Pulling the cord to remove the plug may cause the cable to break.
Adjusting the mist output
-
Push the power button to turn the device on.
The power/water supply indicator will light blue and it will begin to humidify with MIN (minimum) mist output. The bottom light will lid up. -
Push the mist button to change the mist volume. The mist volume switches from MAX (maximum) to MIN (minimum) and back, each time the mist switch button is pushed. The switched mist output display is lit. The mist output will always be on MIN (minimum) when the power is turned on, even if the mist output was on MAX (maximum) before powering off.
Caution : Please take adequate care to prevent excessive humidity. Wet floors from condensation can form due to the room environment and conditions of use. Please carefully adjust or turn off the device.
Adjusting the bottom light
1 Push the light button. The light will automatically light up when the power is turned on. The light will light up again when the power is turned on again, even if it was previously switched off.
Functions
Note: see product overview (chapter 1) for reference.
-
Top cover
The structure of the device allows the mist to be efficiently distributed. Always keep this cover on when using the device. Hold and lift the tab of the top cover to remove the top cover. -
Mist outlet
This is where the mist comes out. Blocking the outlet may cause breakdowns. -
Water tank
Remove the tank from the device and fill it with water. -
Power/water supply indicator
Blue indication means that the device is powered on. When it blinks red, the water needs to be refilled. -
Mist output indicators
The selected mist output is lit. Mist volume MIN (minimum) is on as the default setting. -
Power button
Turns on or turns off the power every time you press it. -
Mist output button
You can switch between the MAX (maximum) and MIN (minimum) levels of mist output each time you press it.
Caution: Please be careful not to over humidify. Depending on the room size, environment, and use, it can lead to wet floors due to condensation. -
Light button
You can switch the bottom light off and on each time you press this button. -
Power cable
Directly connect the plug to a wall outlet. -
Water tank cap
Please remove the cap when pouring water into the water tank. After pouring, close it tightly. -
Anti-scale and antibacterial cartridge
This cartridge will reduce the hardness of the water and prevent white dust produced by ultrasonic mist. It also removes bacteria from the water for hygienic mist output. -
Water supply entrance
Use this entrance to fill the tank with water. -
Ultrasonic membrane
Mist is created due to ultrasonic sound waves. You can adjust the amount of mist with the mist button.
Caution: Please regularly clean the device for long-lasting use. Depending on the hardness of the local tap water, we advise to use distilled water.
Maintenance
Important: Be sure to remove the power plug from the outlet before
carrying out maintenance.
Important: Do not soak or immerse the power plug or the device in water.
Daily maintenance
- Switch the power button to OFF and remove the power plug;
- Remove the top cover and water tank from the device.
- Remove the water tank from the device and throw away the water remaining in the water tank.
- Pour a small amount of water into the water tank, firmly close the water tank cap, and shake to rinse.
Note: Only drain water via the designated side, marked with a label. If you drain via the other side, the product will leak and can lead to short cut.
Regular maintenance
Note: If using on consecutive days, please carry out maintenance by applying the following procedure every 3 days. If this type of maintenance is not conducted, scale may form on the inside and shorten the life of the equipment or cause a breakdown. Moreover, if the device continues to be used with no maintenance, it may lead to the growth of bacteria and mold/bad odor.
- Switch the power button to OFF and remove the power plug;
- Remove the top cover and water tank from the device.
- Remove the remaining water in the water tank and at the bottom of the device.
- Add dishwashing detergent to a soft sponge for dishes and wash the water surface and water tank. Pour the water on the right side of the Tag to prevent water from getting into the air tube.
- Rinse the water tank well so that no washing up liquid remains and dry the water tank thoroughly.
- Gently clean the surface of the ultrasonic membrane with a soft, dry cloth.
- After soaking a soft cloth in lukewarm water, wring and wipe off the dirt on the bottom and sides.
Attention: Please do not use metal scourers, melamine sponges, polishing powers, or solvents like benzene, thinner, alcohol or other. Watch this video on YouTube for detailed monthly maintenance instructions:
Maintenance before storing
Please conduct the following maintenance before storing the device:
- Follow the same steps under ‘Regular maintenance’
- Dry each component before assembling it 3 Check that each component has fully dried, then assemble the device and store it.
Anti-scale and antibacterial cartridge
The filter cartridge (art. no. DXHUC01) needs to be replaced every 3 to 6
months depending on usage and water hardness.
Attention: When replacing the filter, please do not dispose of the cap of the water tank (component 10 in chapter 1).
Spare parts
Spare parts and accessories can be requested at the point of purchase or local
distributor.
Technical specifications
The appearance and specification of the device may be changed without notice.
FAQ
-
Q. The power/water supply indicator does not light up and mist does not come out.
A. – Is the power plug inserted to the back of the socket? – Is there a power cut? -
Q. The power/water supply indicator is red and the power is off, even though the power button is pushed.
A. There is not enough water. Please fill the water tank with water. -
Q. Strange noises accompany the use of the product.
A. A “burbling” sound comes out of the main body. This sound is the sound of water being supplied from the water tank to the main body and does not mean the product is defective. -
Q. A strange noise can be heard from the removed water tank.
A. When you remove an empty or nearly empty water tank from the main body, an abnormal sound from the water tank can be heard.
This sound is related to pressure within the water tank and does not mean the product is defective. -
Q. Mist can’t be seen even when the power is connected.
A. Is the power/water supply display flashing red? There is insufficient water, if it is flashing red. Please fill the water tank with water.
The mist may not be visible depending on the balance between the room temperature and humidity. -
Q. The mist volume is switched to MIN (minimum) even though it is not being used.
A. Was the power turned on again? The default mist volume will be MIN (minimum) if the power is turned on again, even if the mist volume was on MAX (maximum) before switching it on. -
Q. The bottom light is on even though it is not being used.
A. Was the power turned on again? The light will be on if the power is turned on again, even if the bottom light is turned off. -
Q. The floor is wet / There is a water leakage.
-
A. Is the floor wet due to excessive humidity?
-
Wet floors from mist can occur due to the room environment and conditions of use. Please switch the mist volume to MIN (minimum), and carefully adjust or turn off the device.
-
A unique feature of the ultrasonic humidifier is that, while it has a strong humidifying ability, the mist that forms is light, and therefore doesn’t soak the surrounding area. We recommend the use of an external hygrometer to monitor humidity.
-
Q. How often should I replace the anti-scale and antibacterial cartridges?
-
A. Depending on usage and hardness of the water, we recommend replacing the cartridge every 3 to 6 months. We strongly advise to use the cartridge as it will extend the lifespan of your device.
-
Q. The water tank is full but the LED keeps flashing red.
-
A. Make sure the float (component 14 in chapter 1) is not fixed. Gentle nudge it lose with your finger to activate the empty water tank sensor
Disposal
The European Directive 2012 / 19 / CE on Waste Electrical and Electronic Equipment (WEEE), requires that old household electrical appliances must not be disposed of in the normal unsorted municipal waste stream. Old appliances must be collected separately to optimize the recovery and recycling of the materials they contain and reduce the impact on human health and the environment. The crossed-out “wheeled bin” symbol on the product reminds you of your obligation, that when you dispose of the appliance it must be separately collected. Consumers should contact their local authority or retailer for information concerning the correct disposal of their old appliances.
Simplified EU declaration of conformity
The full text of the EU Declaration of Conformity is available at the
following internet address: www.duux.com/doc
Designed in The Netherlands by Duux BV. Made in P.R.C.
Duux BV, P.O. Box 145, 5400 AC Uden Netherlands,
www.duux.com
© 2021 Duux. All rights reserved.
- DUUX® is a trademark of Duux BV, registered in the EU and other countries.
- The brand cited belongs exclusively to the respective owners.
- Specifications are subject to modification without notice.
Version: IMDXHU1415_V1
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>