CK1100 Automatic Sliding Gate Opener
Product Information
Specifications:
- Model: CK1100
- Power input: Motor voltage
- Rated power
- Gate moving speed
- Max gate weight
- Environmental conditions
- Protection class
Product Usage Instructions:
Check Your Gate before Installation
Before installation, it is important to check your gate for any
damages or defects. If any damage is found, please contact your
dealer for assistance. Make sure to dispose of any packaging
materials according to the current regulations.
General Safety
Ensure that a positive stop is mounted on both ends of the
ground track for safety purposes.
Preparation for Installation
Follow the installation instructions provided in the user
manual. The manual contains important information about safety,
installation, operation, and maintenance. It is crucial to read and
understand these instructions before proceeding with the
installation.
Parts List
The product may include accessories parts. Please refer to the
actual package for the included parts list.
Optional Accessories Parts List
Additional accessories are available at TOPENS Store. These
include:
- M12 Remote Control
- ERM12 External Receiver
- TC186-R WiFi Smartphone Remote Control with Camera
- TC188 Universal Wireless and Wired Keypad
- TKP3 Wireless Keypad
- TC175P Wired Keypad
- HLR01 HomeLink Remote Control Kit
- TC173 Wireless Push Button
- TC147 Wall Push Button
- TC148 Waterproof Wall Push Button
- TRF3 Reflection Photocell Sensor
- TC102 Photo Eye Beam Sensor
- JD110VY / JD230VY AC Warning Light
- LT08B 20 Feet Roller Chain
- Replacement Parts (ACPYMJ7A Control Board (120V), ACPYMJ8A
Control Board (230V), PYMJ-CKG Limit Switch)
WARNING:
Any changes or modifications not expressly specified by this
user manual may void the warranty of the equipment.
Frequently Asked Questions (FAQ)
Q: Where can I purchase the product?
A: You can purchase the product from various online retailers
such as Amazon.com, Amazon.ca, Amazon.co.uk, and Amazon.de. If you
have purchased from a different retailer, please specify.
Q: What information should I provide when contacting TOPENS for
technical service or assistance?
A: When contacting TOPENS for technical service or assistance,
please provide the following information:
-
Order#
-
Product Model
-
Purchase Date
-
Full Name
-
Phone#
-
Email Address (VERY IMPORTANT)
-
Street Address, Apartment /Unit, City, State /Province, Zip
Code Country/Region -
Approximate Gate Weight (pounds; kg: Other. Please
Specify) -
Approximate Gate Length (feet; meter; Other. Please
Specify) -
Did you purchase any accessories? (Please list below)
-
Issue Details
Q: How can I contact TOPENS for support?
A: You can contact TOPENS for support via email at
support@topens.com or by calling +1 (888) 750 9899 (Toll-Free USA
& Canada).
Sliding Gate Opener User’s Manual
Model:
CK1100
TOPENS Website
www.topens.com
Email: support@topens.com
Please read and follow all warnings, precautions and instructions before
installation and use.
Periodic checks of the opener are required to ensure safe operation. Save this
manual.
C030614
VER 22c
CONTACT US:
Visit: www.topens.com
Please record the product model, your email address etc.
in the spaces provided below. Refer to this list when contacting TOPENS
for technical service or assistance with your automatic gate opener.
Where did you purchase? (Amazon.com; Amazon.ca: Amazon.co.uk, Amazon.de;
Other, Please Specify)
Order#
Product Model
Purchase Date
Full Name
Phone#
Email Address (VERY IMPORTANT)
Street Address, Apartment /Unit, City, State /Province, Zip Code Country/Region
Approximate Gate Weight (pounds; kg: Other. Please Specify)
Approximate Gate Length (feet; meter; Other. Please Specify)
Did you purchase any accessories? (Please list below)
Issue Details
Email Us: support@topens.com Call: +1 (888) 750 9899 (Toll Free USA & Canada)
Table of Contents
Check Your Gate before Installation ……………………………………………………………………………………………………1
General Safety ………………………………………………………………………………………………………………………………… 1 Preparation
for Installation …………………………………………………………………………………………………………………2 Parts List
………………………………………………………………………………………………………………………………………… 4 Accessories Parts
(Included in some models, refers to the actual package) ……………………………………………4
Optional Accessories Parts List (Available at TOPENS Store)
……………………………………………………………….5 Replacement Parts
……………………………………………………………………………………………………………………………5 Technical Specifications &
Features ……………………………………………………………………………………………………6 Installation Overview
…………………………………………………………………………………………………………………………6 Installation of the Opener
…………………………………………………………………………………………………………………..7 Manual Operation
……………………………………………………………………………………………………………………………..7 Installation of chain and
chain brackets ……………………………………………………………………………………………… 8 Installation of the
Magnets …………………………………………………………………………………………………………………9 Connecting of Power
Supply …………………………………………………………………………………………………………… 10 Connecting of the Control
Board ……………………………………………………………………………………………………… 10 Setting of the Control Board
……………………………………………………………………………………………………………. 12 Test the Reversing Sensitivity
…………………………………………………………………………………………………………..13 How to Program or Erase the
Remote ……………………………………………………………………………………………… 13 How to Use the Remote to
Operate Your Gate Opener ……………………………………………………………………….14 Wireless Keypad
Programming ……………………………………………………………………………………………………….. 14 Maintenance
………………………………………………………………………………………………………………………………….. 16
Thank you for purchasing our sliding gate opener. We are sure that the
products will be greatly satisfying as soon as you start to use it. The
product is supplied with a user’s manual which encloses installation and
safety precautions. These should be read carefully before installation and
operation as they provide important information about safety, installation,
operation and maintenance. This product complies with the recognized technical
standards and safety regulations.
Check Your Gate before Installation
General Safety
WARNING! An incorrect installation or improper use of the product can cause
damage to persons, animals or properties. · Scrap packing materials (plastic,
cardboard, polystyrene etc.) according to the provisions set out by current
standards. Keep nylon or polystyrene bags out of children’s reach. · This
product was exclusively designed and manufactured for the use specified in the
present documentation. Any other use not specified in this documentation could
damage the product and be dangerous. · The factory declines all responsibility
for any consequences resulting from improper use of the product, or use which
is different from that expected and specified in the present documentation. ·
Do not install the product in explosive atmosphere. · The factory declines all
responsibility for any consequences resulting from failure to observe Good
Technical Practice when constructing closing structures (door, gates etc.), as
well as from any deformation which might occur during use. · Disconnect the
electrical power supply before carrying out any work on the installation. Also
disconnect any buffer batteries, if fitted. · Fit an omnipolar or
magnetothermal switch on the mains power supply, having a contact opening
distance equal to or greater than 3,5 mm. · Make sure a residual current
circuit breaker with a 30mA threshold is fitted before the power supply mains.
· Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an earth
terminal. · Fit all the safety devices (photocells, electric edges etc.) which
are needed to protect the area from any danger caused by squashing, conveying
and shearing.
1
· Position at least one visible indication device, and fix a Warning sign to
the structure.
· The factory declines all responsibility with respect to the automation
safety and correct operation when other supplier’s components are used. · Only
use original parts for any maintenance or repair operation. · Do not modify
the automation components, unless explicitly authorized by the factory. ·
Instruct the product user about the control systems provided and the manual
opening operation in case of emergency. · Do not allow persons or children to
remain in the automation operation area. · Keep radio control or other control
devices out of children’s reach, in order to avoid unintentional automation
activation. · The user must avoid any attempt to carry out work or repair on
the automation system, and always request the assistance of qualified
personnel. · Anything which is not expressly provided for in the present
instructions is not allowed. · Before installing the gate opener, check that
all moving part as well as the sliding gate is in good mechanical condition,
correctly balanced and opens and closes properly. · Save these instructions
for future use.
Preparation for Installation
Before proceeding to your opener installation, check if your gate structure is
in accordance with the current standards, especially as follows: The gate
sliding track is linear and horizontal, and the wheels are suitablethe gate
should be mounted and moving freely. Check that the structure is sufficiently
strong and rigid, Make sure that the gate is plumb and level. The fence posts
must be mounted in concrete. The gate does not bind or drag on the ground. ·
The opening and closing gate stops are positioned.
WARNING: Remember that control devices are intended to facilitate gate
operation, but can not solve problems due to any defects or deficiency
resulting from failure to carry out correct installation or maintenance. Take
the product out of its packing and inspect it for damage. Should it be
damaged, contact your dealer. Remember to dispose of its components
(cardboard, polystyrene, nylon, etc.) according to the current prescriptions.
Refer to the following Figures for gate installation.
2
In sake of safety, a positive stop must be mounted on the two end of ground
track.
3
Parts List
Accessories Parts (Included in some models, refers to the actual package)
4
Optional Accessories Parts List (Available at TOPENS Store)
M12 Remote Control
ERM12 External Receiver
TC186-R WiFi Smartphone Remote Control with Camera
TC188 Universal Wireless and Wired
Keypad
TKP3 Wireless Keypad TC175P Wired Keypad
HLR01 HomeLink Remote Control Kit
TC173 Wireless Push Button
TC147 Wall Push Button
TC148 Waterproof Wall Push Button
TRF3 Reflection Photocell Sensor
TC102 Photo Eye Beam Sensor
JD110VY / JD230VY AC Warning Light
LT08B 20 Feet Roller Chain
Replacement Parts
ACPYMJ7A Control Board (120V)
ACPYMJ8A Control Board (230V)
PYMJ-CKG Limit Switch
WARNING: Changes or modifications not expressly specified by this user manual, TOPENS could void the warranty of this equipment.
5
Technical Specifications & Features
Specifications
CK1100
Power input: Motor voltage: Rated power: Gate moving speed: Max gate weight: Environmental conditions: Protection class:
110~120V/60Hz or 220~240V/50Hz 120VAC or 230VAC 450W 20 cm/s (8 in/s) 1300kg
(2800lbs)
-20~ +50 (0°F to 120°F) IP44
Features:
·Midway mode. ·Quick selection for the gate open/close direction ·Reliable
rolling code technology for remote control ·Emergency release key in case of
power failure ·Stop in case of obstruction during gate opening ·Reverse in
case of obstruction during gate closing ·Built in adjustable auto-close (1-99
seconds)
·Built in max. Motor Running Time (MRT) for multiple safety protection (90 seconds) ·Reliable electromagnetism limit for easy adjustment ·Can be equipped with a wide range accessories ·Easy to install, and minimum maintenance requirement ·Get the desired chain tension by adjusting the chain bolts
Installation Overview
6
Installation of the Opener
Caution: Be sure that the opener is installed in a level and paralleled
position. Improper installation could result in property damage, severe
injury, and/or death. Before starting installation, ensure that there is no
point of friction during the entire movement of the gate and there is no
danger of derailment. * Ensure that the safety side rollers are present.
Necessary Tools: The following tools may be necessary to install the Gate
opener. You will need screwdrivers, an electric drill, wire cutters and a wire
stripper, a socket set, and possibly access to a welder. When install the
opener, you should build a concrete pad to support the base plate of opener in
order to maintain proper stability. The installation proceeds are as follows:
1.Assemble the Base Plate and fix the Opener to the Base Plate. 2.Dig a hole
for a concrete pad which should be approximately 60 x 32 x 35cm (24x 13x 14).
It may protrude 10 cm (4″) above ground and 25 cm (10″) in depth underground.
Increase the pad height if necessary to protect the system from flooding,
heavy snow etc. 3. Prepare one or more conduits for the electrical cables
before pour concrete. Remember that cable conduits have to pass through the
hole on the base. 4. Pour concrete and before it starts to harden, check that
it is parallel to the gate leaf and perfectly level. 5. Mark the position of
four expansion anchors according to the position of mounting hole on the base
plate. Double check your marking, move the base plate and drill the 4 holes
using a 14mm (9/16″) masonry bit. Put the 4 expansion anchors (provided) into
the holes and firmly tighten. 6. Mount the base plate to the concrete Pad and
firmly tighten, enabling the opener is firmly secured on the concrete pad
during the whole gate travel.
Manual Operation
You can open the gate by manual when power failure. And the opener should be
put in the manual (emergency release) position before fitting the rack,
installing the opener and limit switch. The process is as follows: Insert the
Release Key and turn it in clockwise 90°, then pull the release handle in
clockwise 90° to disengage the clutch between the gear shaft and motor. Now
the opener is in the manual operation.
7
Installation of chain and chain brackets
1. Chain Brackets
1). Please refer to below chain brackets figure, which shows “U” bolt, “L”
bracket and chain bolt. Use the “U” bolts (square or round) to attach the
chain brackets to gate frame. 2). If Both the square bolts and round bolts are
not fit for the gate frame, use the appropriate bolts to attach the chain
brackets to gate frame.
2. How to install the chain
1). Place the chain around the top of the idler wheels and under the drive
sprocket in chain box. 2). Connect a chain bolt to one end of chain from chain
box by using master link. Then insert the chain bolt to the L bracket and fix
them each other by washers and nuts temporarily. (Nuts will be further
adjusted for a proper chain tension later) 3). Connect second chain bolt with
another end of chain from chain box, then attach bolt to the L bracket on
opposite end of gate using the washers and nuts. 4). Make sure that the chain
is line up exactly with the position where the chain on the chain idler wheel.
5). Remove the unwanted length of chain. Set appropriated chain tension by
adjusting two chain bolts of the both end.
6). The chain brackets must be mounted to the same height as the chain on the
idler wheels.
8
7). Make sure there is 1″ distance at least between the wheel cover and the
gate after you position the base plate.
Installation of the Magnets
Before install limit switch, make sure the gate opener is put in manual
operation. (the clutch connected with gear shaft is disengaged) and the mains
power supply is disconnected. Position the two Magnet Components approximately
on the gate and move the gate by hand to fix them in place. Fit magnets
bracket Push the gate fully closed by hand. Locate and install the magnet
bracket so that the opener will stop at the desired close position when the
close limit switch approaches it. Push the gate fully open by hand. Locate and
install the magnet bracket so that the opener will stop at the desired open
position when the open limit switch approaches it. The magnet component with S
pole must be installed at left side and the magnet component with N pole must
be installed at right side from the view inside of property. Ensure magnet
center to align with the marked line above ! The magnets should be 25~30mm
(1-1.2″) away from the Limit Switch Box. If it is too near or too far, the
switches will fail to work. Adjust the position of the magnets until the
positions of the opening and closing meet the requirement.
Warning: Improper magnets installation may cause the gate crash into end
barrier,
which is very dangerous !
9
Connecting of Power Supply
WARNING: NEVER connect the gate opener to the power outlet before all the
installations have been done. The power supply cord should be at least
3×0.75mm2 (3C×18AWG). Connect the live wire and neutral wire to the “L” (2)
and “N” (1) terminal of the control board respectively; and connect the earth
wire to “PE”. NOTE: The power supply cord is not included in the package.
10
Connecting of the Control Board
1. Motor The BLACK wire of the motor should be connected into the “3”
terminal. The YELLOW wire of the motor should be connected into the “4”
terminal. The RED wire of the motor should be connected into the “5” terminal.
2. Limit Switches The YELLOW wire of the limit switches should be connected
into the “8” terminal. The BLACK wire of the limit switches should be
connected into the “9” terminal. The RED wire of the limit switches should be
connected into the “10” terminal. 3. Warning Light (Included in some models,
refers to the actual package) One wire of the warning light should be
connected into the “6” terminal, another should be connected into the “7”
terminal. 4. Start Capacitor The two wires of the start capacitor should be
connected into the “4”terminal and “5” terminal. 5. Photocell Beam System
(PBS) (Included in some models, refers to the actual package) Use a 2-core
cable to connect the “+ ~” terminal of the photocell’s emitter to the “11”
terminal, the “- ~” terminal to the “13” terminal. Also the “+ ~” and “- ~”
terminals of the photocell’s receiver should be connected to the “11” and “13”
terminals in parallel. Use another 2-core cable to connect the “COM” terminal
of the receiver to the “13” terminal, the “NC” terminal to the “12” terminal.
6. Reflection Photocell Sensor (optional) The “AC10-25V/DC12-30V” terminals of
the reflection photocell sensor should be connected to the “11” and “13”
terminals, no matter the polarity. The “NC” terminal should be connected to
the “12” terminal. The “COM” terminal should be connected to the “13”
terminal.
7. Wired Keypad (12VDC) (Optional) The RED wire of the wired keypad should be
connected into the “11” terminal. The BLACK wire of the wired keypad should be
connected into the “13” terminal. The PURPLE wire of the wired keypad should
be connected into the “13” terminal. The BLUE wire of the wired keypad should
be connected into the “14” terminal. 8. Push Button (Optional) The push button
should be wired to the “13” and “14” terminals. The gate operator works
alternately by pushing the button (open-stop-close-stop-open). 9. External
receiver (optional) The RED wire of the external receiver should be connected
into the “#11” terminal. The BLACK wire of the external receiver should be
connected into the “#13” terminal. The BROWN wire of the external receiver
should be connected into the “#14” terminal.
11
10. HomeLink Remote Control Kit (optional) The “1” terminal should be connected to the “13” terminal. The “2” terminal should be connected to the “14” terminal. The “DC+” terminal should be connected to the “11” terminal. The “DC-” terminal should be connected to the “13” terminal.
Setting of the Control Board
WARNING: Ensure the gate opener is Power Off when you make any adjustment of
the gate opener. Keep away from the gate during you set the gate opener system
in case of the unexpected gate moving. Carefully adjust the DIP switches to
avoid the risk of machine damage and injury or death. Always ask the help of
professional technician /electrician if you have any question. 1. DIP Switches
The DIP switches are used to set the running time of the motor in pedestrian
mode, enable/disable auto close function of the gate operator and fast change
the open/close direction which is determined by the position of the gate
operator installed. DIP Switch #1#2: Running time of the motor in Midway Mode
DIP Switch #1: ON 2 Seconds OFF 0 DIP Switch #2: ON 4 Seconds OFF 0
NOTE: The midway mode function would be disabled if both DIP switches are
turned off. Factory default setting is disabled. The midway mode could be
activated by pressing button B of the remote control when the gate is in the
full closed position.
E.g.
Running time of the operator in midway mode is 2 seconds.
DIP Switch #3: Auto close function enabled/disabled DIP Switch #3: ON auto
close function enabled
OFF auto close function disabled
E.g.
Auto close function of the opener has been enabled. Factory default setting is disabled.
Important Note: When the auto close function is enabled, the photocell sensor is highly recommended to be installed with the gate opener for safety.
12
DIP Switch #4: Left/Right open
2. Potentiometers Potentiometer A and B are used to adjust the stall force
and auto close time of the gate operator separately. Turn potentiometer A
clockwise to increase the stall force, and turn it counter-clockwise to
decrease the stall force.
WARNING: Photocell is highly recommended to be installed with the gate opener
as entrapment protection for safety when you set stall force to maximum. Turn
potentiometer B clockwise to increase the auto close time, and turn it
counter-clockwise to decrease the auto close time, the auto close time could
be adjusted gradually from 1 to 99 seconds.
Test the Reversing Sensitivity
For the sake of safety, it is very important to test the reversing sensitivity
as soon as the control board set is finished. The reversing sensitivity
adjustment is inverse correlation with stall force adjustment in potentiometer
A. In other word, the stall force level is higher; the reversing sensitivity
level is lower. Put an immobile object along the gate path, and then operate
the gate to strike it during the close cycles. The gate must reverse as soon
as object is struck with it. If the gate doesn’t reverse, please increase the
reversing sensitivity by turning the potentiometer A in counter-clockwise
direction. (Turning the stall force potentiometer toward to MIN position to
increase the reversing sensitivity) Note 1: If the sensitivity setting is too
higher, the gate will stop or reverses very easy by itself while there is
little obstruction or resistance such as strong wind or heavy snow sometimes.
Note 2: Always check the gate reversing function every each time of control
board set or restart after power off.
How to Program or Erase the Remote
The remote MUST be programed to the opener BEFORE OPERATING. Please follow the
steps to program the remote.
13
Activate the opener only when gate is in full view, free of obstruction and
properly adjusted. No one should enter or leave gate area while gate is in
motion. DO NOT ALLOW CHILDREN to operate push button or remote. DO NOT ALLOW
CHILDREN TO PLAY NEAR THE GATE.
If you purchase additional remote controls, the gate opener must be programmed
to accept the new remote code.
If you lose one of any remote control, please erase and reprogram all other
remote controls to have a new code for safety.
Program the remote Press and release the LNSW button, the LEARN LED light will
be on, then press the key A or B on the remote two times in 2 seconds, between
the two times HOLD ON FOR A MOMENT, the LEARN LED light will flash for 4
seconds. Now the remote has been programmed successfully. Erase all the remote
codes Press and hold the learn button until the LEARN light is off. Now all
remote codes have been erased. Max. 8 remotes can be programmed for the
opener. An External Receiver (optional) allows up to
250pcs remotes to be programmed for the opener. TOPENS ERM12 Universal
External Receiver is available at TOPENS Store. TOPENS ERM12 Universal
External Receiver is also compatible with other brand swing gate opener,
sliding gate opener and garage door opener.
How to Use the Remote to Operate Your Gate Opener
Each remote has four buttons, from top to bottom are separately A, B, C and D.
You may use this remote to operate as many as 4 sets TOPENS swing gate openers
or 1 set TOPENS sliding gate opener and 2 sets TOPENS swing gate openers. 1.
Use this remote to only operate TOPENS swing gate opener A, B, C and D four
buttons share same function once they are programmed with TOPENS swing gate
opener. You may choose any button to program it with our swing gate opener.
Every press of the button is able to active the gate opener to work
alternately (open-stop-close-stop-open). 2. Use one remote to operate TOPENS
swing gate opener & sliding gate opener at the same time All of TOPENS sliding
gate opener have midway mode. Button B is designed to realize midway function
(refer to more details in our TOPENS sliding gate opener manual). So it is
must program button A with sliding gate opener, while you may program either C
button or D button with TOPENS swing gate opener.
Wireless Keypad Programming
You can follow the below steps to program wireless keypad to the opener. Press
the LNSW button until the LEARN LED is ON, and then releases the button. Then
press “OK” button on keypad and LEARN LED will flash for 3 seconds and then be
OFF which indicates the keypad has been programmed successfully. You can use
the default password “888888” to operate the opener after programming. You can
press “PIN” “8 8 8 8 8 8” and then press “OK” to confirm to operate the
opener.
14
Also you can change the password of the keypad follow the below steps. Press “PIN” and then input the six digits old password and then press “PIN” again, the LEARN LED will be ON. Input the six digits new password and then press the “PIN” to confirm the new setting, LEARN LED will flash for 3 seconds and then be OFF which indicates the password has been changed successfully. You can press “PIN” “6 digits new password” and then press “OK” to confirm to operate the opener.
NOTE: Every step for pressing button during program must be finished within 1
second to ensure successful programming.
Troubleshooting
Have a multimeter to check voltage and continuity. Use caution when checking high voltage terminals.
Symptom
Possible Solution(s)
The opener does not run.
1. Check the input voltage of the control board. It should be local AC electricity. 2. Check the fuse in the control board. Replace the fuse if it was burnt out. 3. Ensure the remote control has been programmed to the control board before operating. 4. The thermal protector is working because the high temperature after long working time. Please wait for 20 minutes to let the motor become cold. 5. Check the installing position of the limit magnets. The opener would not run if both of the limit switches are activated by one magnet. 6. Check the limit switch. Remove the wire connection of the limit switch which is connected to the 8#, 9#, and 10# terminals of the control board and then use a jumper wire to short the 3 terminals together to try it again. Replace the limit switch if the motor could run in both directions. 7. Check the control board. Replace the control board as necessary.
Remote control does not work.
1. The indicator light of remote control is not on. Check the battery in your remote control. Replace the battery as necessary. 2. The distance you use the remote is too far away from the opener. Try it again closer.
15
3. Remote control is not suitable for receiver. After making sure the codes are correct, erase remote controls and then re-program the codes in the device. 4. Check the control board. Replace the control board as necessary.
The gate starts but it is immediately stop or reverse
1. Check the wire connection of hall sensor board with the main control board. 2. The opening force or closing force is adjusted too small. Turn the Potentiometer A to increase the force. 3. Disconnect the gate from the gate opener and check that the gate slides freely without any binding. 4. Check the control board. Replace the control board as necessary.
The gate opens, but stops and will not return.
1. Check the installing position of the magnets. The opener would not run if both of the limit switches are activated by one magnet. 2. Check the limit switch. Remove the wire connection of the limit switch which is connected to the 8#, 9#, and 10# terminals of the control board and then use a jumper wire to short the 3 terminals together to try it again. Replace the limit switch if the motor could run in both directions. 3. Check the control board. Replace the control board as necessary.
The gate can open, but fails to close.
1. Photocell is obstructed. Remove obstruction. 2. Check the limit switch. Remove the wire connection of the limit switch which is connected to the 8#, 9#, and 10# terminals of the control board and then use a jumper wire to short the 3 terminals together to try it again. Replace the limit switch if the motor could run in both directions. 3. Check the control board. Replace the control board if necessary.
The gate will open automatically instead of close after the auto close time
Ensure the DIP 4# has been set correctly according to the installation for “Left Open” or “Right Open”
The motor runs but the gate doesn’t move.
Ensure the clutch for emergency release is adjusted properly and is not slipping.
Maintenance
Every six months check the following items for proper operation of the unit.
Lubricate shafts and sprockets. Keep operator clean at all times. Check
and tighten anchors bolts. Check for loose or corroded wire Ensure the
operator is well earthed, and correctly terminated. Always check the
Stop/Reverse in case of obstruction function when performing any maintenance.
If this function can’t be made operable, remove this operator from service
until the cause of the malfunction is identified and corrected.
16
Feedback & Review
Your comments and suggestions are important to us as they help us provide the
best possible service.
Should you have any need to contact us, the info below will help you get in
touch:
TOPENS Website
www.topens.com
Contact Us: E-mail: support@topens.com Kindly include your Product Model,
Purchasing Date & Site, Order #, and your contact information. All your
concerns will be replied within 24 hours. Tel: +1 (888) 750 9899 (Toll Free
USA & Canada)
References
- Amazon.ca
- Low Prices in Electronics, Books, Sports Equipment & more
- Amazon.com
- Amazon.de: Günstige Preise für Elektronik & Foto, Filme, Musik, Bücher, Games, Spielzeug & mehr
- TOPENS Gate Opener Automatic Gate System
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>