OMCAN BB-CN-230S Back Bar Cooler Instruction Manual
- June 14, 2024
- OMCAN
Table of Contents
Back Bar Cooler
Model BB-CN-230S
Item 47587
Instruction Manualwww.omcan.com
Revised – 02/16/2023
Disclaimer
OMCAN IS NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS. WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75°F AND 55% RELATIVE HUMIDITY, AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRECTLY TOA FLOOR DRAIN.
General Information
Omcan Manufacturing and Distributing Company Inc., Food Machinery of America,
Inc. dba Omcan and Omcan Inc. are not responsible for any harm or injury
caused due to any person’s improper or negligent use of this equipment. The
product shall only be operated by someone over the age of 18, of sound mind,
and not under the influence of any drugs or alcohol, who has been trained in
the correct operation of this machine, and is wearing authorized, proper
safety clothing. Any modification to the machine voids any warranty, and may
cause harm to individuals using the machine or in the vicinity of the machine
while in operation.
CHECK PACKAGE UPON ARRIVAL
Upon receipt of an Omcan shipment please inspect for external damage. If no
damage is evident on the external packaging, open carton to ensure all ordered
items are within the box, and there is no concealed damage to the machine. If
the package has suffered rough handling, bumps or damage (visible or
concealed), please note it on the bill of lading before accepting the delivery
and contact Omcan within 24 hours, so we may initiate a claim with the
carrier. A detailed report on the extent of the damage caused to the machine
must be filled out within three days, from the delivery date shown in the
shipping documents. Omcan has no recourse for damaged products that were
shipped collect or third party.
Before operating any equipment, always read and familiarize yourself with all
operation and safety instructions.
Omcan would like to thank you for purchasing this machine. It’s of the utmost
importance to save these instructions for future reference. Also save the
original box and packaging for shipping the equipment if servicing or
returning of the machine is required.
Safety and warranty
HANDLING AND INSTALLATION
Handle with care
Unplug from the wall socket before moving. Never tilt the refrigerator over 45
degrees during handling.| Storage
Always store the refrigerator in a dry place.
---|---
Sufficient space
To allow for proper air circulation and increased refrigeration capabilities,
the refrigerator must have at least 4”/10cm of space between wall/ceiling and
the machine.| Proper ventilation
Always place the refrigerator in an area with good ventilation. For first time
use, set in location and wait at least 2 hours before plugging into wall
socket.
Away from heat source
Never place the refrigerator near any type of heat source or in direct
sunlight, as it reduces refrigeration capabilities.| No heavy load
Never put heavy items on top of the refrigerator.
No altercations/tampering
Never tamper with or make changes to the refrigerator. Changes and add-ons
should not be installed to the inside or outside of the refrigerator.|
Stable location
Unpack and place the refrigerator on flat, solid ground.
PREPARATION AND POWER SUPPLY
Exclusive power outlet
Power supply should be 110V, single phase AC with exclusive single phase three
pin outlet (125V/15A). The power outlet must be in close proximity to the
ground.| No shared power outlets
Refrigerator cable should never share the power outlet with any other
appliance, as cable will overheat and may result in a fire.
---|---
Protect cables
Extra caution should be used when handling cables, as broken or damaged cables
can cause sparking and may result in a fire.| No water flushing
Never flush the refrigerator surface. This can cause leakage, which may result
in electrical damage or fire.
Never store flammables and explosives
No explosives or flammables should be stored in, or in proximity to, the
refrigerator, such as gasoline, alcohol, and adhesives.| No spray
Never spray flammables such as paint or coating near the refrigerator. This
may cause fire or malfunction.
After power outage
After a power outage or the unplugging of the refrigerator, wait at least 5
minutes before plugging it back in.| No medicine
Medicine should not be stored inside of the refrigerator.
RESIDENTIAL USERS: Vendor assumes no liability for parts or labor
coverage for component failure or other damages resulting from installation in
non-commercial or residential applications. The right is reserved to deny
shipment for residential usage; if this occurs, you will be notified as soon
as possible.
1 YEAR PARTS AND LABOUR wARRANTY
Within the warranty period, contact Omcan Inc. at
1-800-465-0234 to schedule an Omcan
authorized service technician to repair the equipment locally.
Unauthorized maintenance will void the warranty. Warranty covers electrical
and part failures not improper use.
Please see https://omcan.com/disclaimer for complete info.
WARNING:
The packaging components are classified as normal solid urban waste and can
therefore be disposed of without difficulty.
In any case, for suitable recycling, we suggest disposing of the products
separately (differentiated waste) according to the current norms.
DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!
Technical Specifications
Model | BB-CN-230S |
---|---|
Capacity | 208 L / 7.34 cu.ft. |
Temperature Range | 0 – 8°C / 32 – 46.4°F |
Max Ambient Temp Rating | 24°C / 75°F |
Material | Steel with Coating |
Door Type | Sliding Door |
Number of Doors | 2 |
Refrigerant | R600a (70g) |
Electrical | 110-120V / 60Hz / 1 |
Current | 2.8A |
Dimensions | 35.4” x 20.5” x 35.4” / 900 x 520 x 900mm |
Packaging Dimensions | 38.6” x 22.8” x 39.4” / 980 x 580 x 1000mm |
weight | 112.4 lbs. / 51 kgs. |
Packaging Weight | 134.5 lbs. / 61 kgs. |
Item Number | 47587 |
Installation
Store the unit upright. If the unit has been stored or transported on its
back, front or sides then it must be placed upright for at least 24 hours
before switching on. Place the unit on an even and stable surface as far away
as possible from any sources of heat.
Note: Do not move the unit by lifting either the door or door handle as
this may cause damage to the cabinet.
Please ensure that the unit is spaced appropriately in its surrounding area.
The correct area should give a gap of at least 1.18” between the top of the
cabinet and the underside of the bar itself. As well as between the back of
the unit and the wall. Poor ventilation due to insufficient spacing is likely
to cause reduced cooling, icing up and premature compressor failure.
Operation
GENERAL OPERATION
The cabinet door should remain firmly closed during normal operation. This
prevents warm moist air from entering and creating frost within the cabinet.
If the cabinet is left open for extended periods ice will form. This will
prevent cooling and the machine will then require defrosting.
The unit should be left switched on, and should not be switched off between
trading sessions. The cabinet is designed to chill product in sealed
containers only (bottles, can, etc). It is not recommended that open
containers are placed in the unit for cooling.
CONTROLS
The thermostat control is located below the doors on the front of the
appliance. Refrigeration is switched on and off at the main supply. The light
is controlled independently by using the toggle switch provided at the front
of the unit.
Warning: If the supply cord is damaged, the manufacturer, its service
agent or similarly qualified persons must replace it, in order to avoid a
hazard.
Maintenance
ROUTINE MAINTENANCE
Disconnect from the power supply before cleaning.
- Clean the enclosure and interior of the cabinet as often as possible.
- Clean the unit with moist cloth. Never allow the switch, control panel, cable or plug to get wet.
- Do not use abrasive cleaning agents. These can leave harmful residues.
- Use only mild soapy water.
- Clean the door seal with water only.
- Ensure that no cleaning water penetrates into the electrical components.
- Must not be cleaned by a water jet.
- Always wipe dry after cleaning with soft cloth.
- Take care when cleaning the rear of the cabinet.
- An agent or qualified technician must carry out repairs if required.
- If the cabinet is to be left inactive for long periods, unplug the cabinet after having turned the lamp switch to off position, empty the refrigerating compartment and clean thoroughly.
SPECIAL MAINTENANCE
The instructions given below are for SKILLED PERSONS.
PERIODIC OPERATIONS
- Periodically clean the condenser using suitable tools (vacuum cleaner or soft brush).
- Check that the electrical connection are not loose.
- Check that the thermostat and the sensor are in proper working order.
- Periodically cleaning the condenser can extend the life of the appliance.
- Failure to keep the condenser clean will reduce the refrigeration performance of the cabinet.
- Recommend that agent or qualified technician clean the condenser.
Troubleshooting
Fault | Probable Cause | Action |
---|---|---|
The appliance is not working. | The unit is not switched on. | Ensure the unit |
is plugged in correctly.
Plug and lead are damaged.| Call Omcan.
Fuse in the plug has blown.| Replace the fuse.
Power supply.| Check power supply.
Internal wiring fault.| Call Omcan.
The appliance turns on, but the temperature is too high/low.| Too much ice on
the evaporator| Defrost the appliance.
Condenser blocked with dust.| Call Omcan.
Doors are not properly sealed.| Ensure doors are shut and seals
are not damaged.
Appliance is located near a heat source or air flow to the condenser is being
interrupted.| Move the refrigerator to a more suitable location.
Ambient temperature is too high.| Increase ventilation or move appliance to a
cooler position.
Appliance is overloaded.| Reduce the amount of containers in the appliance.
The appliance is unusually loud.| Loose nut/screw.| Check and tighten all nuts
and screws.
The appliance has not been installed in a level or stable position.| Check
installation position and change if necessary.
| The appliance is not properly leveled.| Adjust the screw feet to level the
appliance.
The appliance is leaking water.| The discharge outlet is blocked.| Clear the
discharge outlet.
The water container is damaged.| Call Omcan.
Parts Breakdown
Model BB-Cn-230s 47587
Item No. | Description | Position |
---|---|---|
AM566 | Foaming Cabinet for 47587 | 1 |
AM567 | Part for Fixing Centre Sill for 47587 | 2 |
AM568 | Centre Sill for 47587 | 3 |
AM569 | Grill for 47587 | 4 |
AE142 | Power Cord for 47587 | 5 |
AM570 | Dry Filter for 47587 | 6 |
AF232 | Condenser Fan Blade for 47587 | 7 |
AM571 | Condenser for 47587 | 8 |
AM572 | Condenser Fan for 47587 | 9 |
AM573 | Condenser Fan Support for 47587 | 10 |
AM574 | Installation Board of Compressor Set for 47587 | 11 |
AM575 | Adjustable Feet for 47587 | 12 |
AM576 | Thermostat Protecting Box for 47587 | 13 |
AM577 | Front Bottom Cover for 47587 | 14 |
AM578 | Thermostat Clip Block for 47587 | 15 |
AM579 | Thermostat Clip for 47587 | 16 |
AM580 | Box of Thermostat for 47587 | 17 |
AM581 | Thermostat Carel for 47587 | 18 |
AM582 | Waterproof Cover of Thermostat for 47587 | 19 |
AM583 | Door Support for 47587 | 20 |
AM584 | Air Flow Circuit Board A for 47587 | 21 |
AM585 | Compressor Wanbao for 47587 | 22 |
AM586 | Drain Pan for 47587 | 23 |
AM587 | Drain Pipe for 47587 | 24 |
AM588 | Spring for Sliding Door for 47587 | 25 |
AM589 | Glass Door – Left for 47587 | 26 |
AM590 | Glass Door – Right for 47587 | 26 |
AM591 | Sliding Door Guide for 47587 | 27 |
AM592 | Door Bumper for 47587 | 28 |
AM593 | Left Cover of Lamp for 47587 | 29 |
AM594 | Switch of Lamp for 47587 | 30 |
AM595 | Lamp Cover for 47587 | 31 |
AM596 | Lamp for 47587 | 32 |
AM597 | Right Cover of Lamp for 47587 | 33 |
AM598 | Shelf for 47587 | 34 |
AM599 | Shelf Support Strip for 47587 | 35 |
AM600 | Shelf Clip for 47587 | 36 |
AM601 | Air Flow Circuit Board B for 47587 | 37 |
AM602 | Evaporator Fan Support for 47587 | 38 |
AM603 | Support – Long for 47587 | 39 |
AM604 | Evaporator Fan Cover for 47587 | 40 |
AD825 | Condenser Fan for 47587 | 41 |
AM605 | Evaporator Cover for 47587 | 42 |
AM606 | Support – Short for 47587 | 43 |
AF226 | Probe Padding for 47587 | 44 |
AM607 | Sensor for 47587 | 45 |
AM608 | Evaporator for 47587 | 46 |
Electrical Schematics
Model BB-Cn-230s 47587
Warranty Registration
Thank you for purchasing an Omcan product. To register your warranty for this
product, complete the information below, tear off the card at the perforation
and then send to the address specified below. You can also register online by
visiting: https://omcan.com/warranty-registration/
For mailing in Canada
For mailing in the US
OMCAN
PRODUCT WARRANTY REGISTRATION
3115 Pepper Mill Court,
Mississauga, Ontario
Canada, L5L 4X5
OMCAN
PRODUCT WARRANTY REGISTRATION
4450 Witmer Industrial Estates, Unit 4,
Niagara Falls, New York
USA, 14305
or email to: service@omcan.comThank you for choosing Omcan
Since 1951 Omcan has grown to become a leading distributor of equipment and
supplies to the North American food service industry. Our success over these
many years can be attributed to our commitment to strengthen and develop new
and existing relationships with our valued customers and manufacturers. Today
with partners in North America, Europe, Asia and South America, we continually
work to improve and grow the company. We strive to offer customers exceptional
value through our qualified local sales and service representatives who
provide convenient access to over 6,500 globally sourced products.
Toll Free: 1-800-465-0234
Fax: 905-607-0234
Email: service@omcan.com
www.omcan.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>