M-ELEC ML-MRBX-OW-10-M-SN Mini Bunker Light Instruction Manual
- June 14, 2024
- M-ELEC
Table of Contents
ML-MRBX-OW-10-M-SN Mini Bunker Light
Instruction Manual
ML-MRBX-OW-10-M-SN Mini Bunker Light
Mini BUNX Weather Protected Bunker
Sparkys all around Australia love the BUNX range of IK10 rated bunker lights and now the range is extended thanks to the BUNX-MINI range. Available with or without a PIR sensor the BUNX-MINI range is available with swappable trims and grills and built in 3CCT’s.
TECHNICAL INFORMATION
ML-MRBX-O-10-M| ML-MRBX-O-10-M-SN| ML-MRBX-OW-10-M| ML-MRBX-
OW-10-M-SN
---|---|---|---
Total Power|
10W*
Lumen Output:| WW 920LM
NW 1000LM
W 1000LM| WW 880LM
NW 1000LM
W 950LM| WW 930LM
NW 1020LM
W 1020LM| WW 920LM
NW 970LM
W 1000LM
Colour Temp:|
3000K (WW)14000K (NW)16000K (W)
IP Rating:|
IP65
IK Rating:|
IK10
CRI:|
80
Efficacy:| WW 103LM/W
NW 115LM/W
W 115LM/W| WW 100LM/W
NW 105LWW
W105LWW| INW107LM/W
NW 117LM/W
W 110LM/W| WW 100LM/W
NW 110LM/W
W 110LWW
Beam Angle:|
120°
Input Current|
0.13A
Inrush Current|
1.6A@240VAC
Dimmable:|
No
Power Supply:|
AC220-240V , built- in non – isolated driver
Power Factor|
0.9
Frequency|
50/60Hz
Average Life:|
56,000hrs”
Dimensions: Base :|
220x120x66
Weight :|
0 . 4KG
Operating Temp|
-20°C to 45°C
Compliance|
SAA
Connection|
PA10 Terminal block
LED Chip Brand|
2835 SMD
Materials:|
Polycarbonate body , diffuser and trim
Warranty :|
5 YEARS
*Total power consumed including driver
** Average life is calculated on expected average lifespan
ADDITIONAL BEZEL ACCESSORIES
INSTALLATION GUIDE
- Ensure all power is off before beginning installation.
- Remove the trim by unscrewing the hex head screw securing the trim. ( A – 1)
- Remove the cover by disassembling the screws securing the diffuser to access the base. ( A – 2)
- Place the included foam gasket onto the wall/area of installation and mark the mounting holes. ( B – 1 )
- Place the base against the wall/ceiling (on top of the gasket) and fix securely using suitable screws/fixing methods. (B – 2, 3, 4 ) If you are running conduit to the base or splicing, remove the knockouts on the sides of the base and trim with a drill. (B)
- Wire up the PA12 terminal block according to the L/E/N marks. (C)
- Select correct output colour on the colour selection switch. (C)
- Seal any holes to maintain ingress protection.
- Reinstall the diffuser and LED board by reconnecting the wires and placing it onto the base and securing it with it’s screws, ensuring that the gasket is properly mated with the diffuser. ( D – 1)
- Reinstall the trim by reassembling the hex head screw to secure the trim. ( D – 2, 3 )
- Test the safety and operation in accordance with all standards.
Operating Voltage | AC220-240V |
---|---|
Power consumption | 1W Max |
Microwave frequency | – |
Transmission power | – |
Detection angle | 90° |
Detection area | 2-6M knob adjustable |
Hold time | 10S-7min knob adjustable |
Daylight sensor | 10-2000LUX knob adjustable |
Stand-by DIM level | – |
Stand-by period | – |
Dimming range | – |
Microwave on/off function | – |
Installation height | 1.8m (recommended wall mount height) |
Minimum mounting distance | 2 – 6m |
Operating temperature | -20°C to 40°C |
Detection area:
The detection area can be adjusted by the knob, clockwise adjustment increases
the sensitivity, counterclockwise adjustment reduces the sensitivity, the
maximum detection distance is 6 meters, the minimum detection distance is 2
meters.
Notice 1: The distance test is carried out under Ta25°C, 1.8 meters wall
mounting installation height.
The test result is based on the movement along the tangential direction of the
sensor, and the detect distance can be adjusted by the dial switch.
Notice 2: Infrared sensor will be affected by temperature. Too high or
too low temperature may affect the detect distance or even cause failure to
sensor.
Hold time:
The hold time can be adjusted by the knob. Clockwise adjustment increases the
hold time, counterclockwise adjustment reduces the hold time, the maximum hold
time is 7min, and the minimum hold time is 10S.
Notice 1: The hold time counting should be started after the sensor is
powered on and initialized.
Daylight sensor:
The light threshold can be selected through the Knob. Clockwise adjustment
increases the light threshold, counterclockwise adjustment reduces the light
threshold, the maximum light threshold is 2000lux, and the minimum light
threshold is 10lux.
Notice 1: The light threshold may cause a large deviation in different
lamps.
PLEASE NOTE
MUST BE INSTALLED BY A LICENSED ELECTRICIAN
- Read instructions carefully before attempting to install the fitting. Retain this guide for future reference
- Disconnect power before installing or servicing
- This fitting is for outdoor use and should not be used in areas with limited ventilation or high ambient temperatures
- Do not extend low voltage cables from the output of power supply
- All components must not be mechanically stressed
- Be careful not to damage or destroy conductive paths on the circuit board
- Follow all relevant electrical and safety standards (including AS3000)
- Correct electrical polarity must be observed as the wrong polarity may destroy the product and is not covered under warranty
- Damage by corrosion will not be honored as a material defect claim. It is the user’s responsibility to provide suitable protection against corrosive agents such as moisture, condensation and other harmful elements
FREE
ONSITE WARRANTY
EXCLUSIVE TO MEMBERS ONL
FREE ONSITE WARRANTY FOR 3 YEARS
INCLUDES PARTS & LABOUR
In conjunction with your standard product warranty
T. 1300 222 445 | www.melec.com.au
For further information about our Warranties please
go to: melec.com.au/legal/warranties
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>