VEVOR 3SDM2-21 Deep Well Submersible Pump Instruction Manual

June 14, 2024
VEVOR

VEVOR-logo

VEVOR 3SDM2-21 Deep Well Submersible Pump

VEVOR-3SDM2-21-Deep-Well-Submersible-Pump-product-
image

Product Information

The product is an electric pump designed for various applications. It comes in different models with different voltage, output power, maximum head, power cord length, and maximum liquid length. The pump is capable of delivering a specific amount of liquid per minute and can handle different temperatures.

Technical Data

Model| Voltage| Output Power| Max. Head| Power Cord Length| Max. Liquid Length| Temperature
---|---|---|---|---|---|---
3SDM2/21| 230Vj 50Hz| 0.55kW| 89m| 20m| Not specified| +35°C
3SDM4/16| 230Vj 50Hz| 0.75kW| 66m| 20m| Not specified| +35°C
3.5SDM4/11| 230Vj 50Hz| 0.75kW| 62m| 20m| Not specified| +35°C
4SDM4/6| 230Vj 50Hz| 0.37kW| 44m| 20m| Not specified| +35°C
4SDM8/9| 230Vj 50Hz| 1.1kW| 57m| 20m| Not specified| +35°C
4SSM4/5| 115Vj 60Hz| 0.5HP (0.37kW)| 51m| 10m| Not specified| +35°C
4SSM5/6| 230Vj 60Hz| 1HP (0.75kW)| 63m| 10m| Not specified| +35°C
4SSM5/8| 230Vj 60Hz| 1.5HP (1.1kW)| 84m| 10m| Not specified| +35°C
4SSM5/12| 230Vj 60Hz| 2HP (1.5kW)| 130m| 10m| Not specified| +35°C
4SSM5/18| 230Vj 60Hz| 3HP (2.2kW)| 195m| 10m| Not specified| +35°C

Product Usage Instructions

Fault Phenomenon: Motor out of operation

  • Possible Reasons:
1. Too much low voltage leads to motor failure.
2. The impeller or stator and rotor are stuck.
3. Power is off.
4. The welding lines of capacitor and protector have fallen.
5. Burnt stator winding or open circuit.
  • Solutions:
1. Adjust the voltage.
2. Clean the impellers and sand-proof cover.
3. Investigate the causes and take appropriate measures.
4. Re-weld the fallen wires or replace them.
5. Send the pump to a maintenance unit for stator winding replacement or repair.

Fault Phenomenon: No water or not enough water amount

  • Possible Reasons:
1. Too much low voltage leads to reduced water amount.
2. The lift exceeds the electric pump’s capacity.
3. The strainer or impeller is blocked.
4. Impellers are seriously worn.
5. There is an open circuit in the stator winding.
  • Solutions:
1. Adjust the voltage.
2. Decrease the lift or consider purchasing another electric pump.
3. Clean the blocked impellers and remove any debris.
4. Replace the worn impeller or send the pump to a maintenance unit for repair.
5. Send the pump to a maintenance unit for stator winding repair or replacement.

Fault Phenomenon: Frequently worked protectors

  • Possible Reasons:
1. Too much low voltage leads to increased current and motor heating.
2. Too much low lift leads to increased water drainage and motor overload.
3. Abnormal wear of rotors or electric pump exposed above water or operated in a high-temperature environment.
4. Damaged sealing causing water leakage.
5. Bearing wear with increased friction force and loud noise.
  • Solutions :
1. Adjust the voltage.
2. Use iron wire to narrow water drainage or reduce the installation height.
3. Protect the electric pump from exposure to water or high temperatures.
4. Replace the damaged sealing or send the pump to a maintenance unit for repair.
5. Replace the bearing in case of serious wear and increased friction force.

Note: The product requires separate refuse collection in the European Union as per Directive 2012/19/EC. Dispose of the product and its accessories marked with the symbol of a crossed-out wheelie bin at a collection point for recycling electrical and electronic devices. Do not discard them with normal domestic waste.

  • We continue to be committed to provide you tools with competitive price.
  • “Save Half”, “Half Price” or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and doses not necessarily mean to cover all categories of tools offered by us.
  • You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with the top major brands.

SUBMERSIBLE PUMP FOR DEEP-WELL

NEED HELP? CONTACT US!

  • Have product questions? Need technical support? Please feel free to contact us: CustomerService@vevor.com
  • This is the original instructions, please read all manual instructions carefully before operating. VEVOR reserves clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there is any technology or software updates on our product.

Thank you for buying our water pumps.
Please read the operation manual carefully before using.

WARNING

  • The reliable grounding must be conducted before using water pump. The earth leakage protective device as well as the overload or over-current protective devic must be installed on water pump.
  • The electric pump is not allowed for dry running.
  • When the pump is in operation, people and animals shall not touch the water near the pump.
  • In order to prevent electrical shock, the power source shall be shut off at maintenance and cleaning.
  • Replacement power cord, Type Y connection-If the power cord is damaged, it must be replaced with a special flexible cord or a special component purchased from its manufacturer or maintenance department.
  • The above installation structure is for reference only. Please purchase the matching parts shown in the figure by yourself.

INTRODUCTION

The deep-well pump is a water lifting tool based on direct connection between electric machine and water pump, which is suitable for fetching underground water from deep wells, rivers, reservoirs and canals etc in some projects. Further, this product is mainly used for farmland irrigation as well as human and animal drinking water in plateau mountain areas. More importantly, the deep-well pump can be used for water supply and discharge in cities, fctories, railways, mines and construction sites.

USE CONDITION

  1. Voltage fluctuating range shall be ±10% of rated values;
  2. The water temperature shall not be higher than +35°C.
  3. The PH value of water is between 6.5 and 8.5.
  4. The solid contents in the water shall not be larger than 0.25% with the maximum diameter not over 2.3mm.

INSTALLATION USE AND NOTICE

  1. Please check whether the inner diameter conforms to the minimum diameter of water pumps before buying and installing. If it is a new well, the air compressor or old water pump shall be used to clean sundries and soils. After that, please check whether the water quality and temperature conform to use conditions. The water pump can only be installed onto the water inside
    the well up to standard.

  2. Please check damage that may be caused in the transportation and storage process after unpacking the pump. For example, whether the cable and plug etc are intact; various joints are not loosened and without any leakage. If there has any damage, please contact with professional personnel to repair or replace it.

  3. During installation, please fix the electric pump and then install the earth leakage protective device or the over-hear or over-current protective device correctly. The electric pump must be connected to ground reliably.

  4. When the water pump reaches a certain length, the motor and the pump body need to be packed separately.

  5. In case of a separate packing, firstly remove the filter screen and the cable protection plate from the pump body (Figure1), then place the pump body on the motor to make the spindle head of the rotor smoothly slide into the coupling, manually rotate the coupling to check if it can run normally, then screw up the connecting bolt(Figure2),and finally install the filter screen and the cable protection plate (Figure3).VEVOR-3SDM2-21-Deep-Well-Submersible-Pump-01 \(3\) VEVOR-3SDM2-21-Deep-Well-Submersible-Pump-01 \(4\)

  6. Before use, thoroughly test the insulation resistance of the electronic pump’s stator winding (including outgoing cable) to the pump casing with a 500V megohmmeter, and the cold insulation resistance should be no less than 100 MO.

  7. The electric pump shall be connected to the power source for trial operation before entering into water. The time shall not exceed 3 seconds. The cable lines of single-phase water pump shall be connected according to the wiring diagram on the electric machine or control cabinet strictly connected by correct colors. The wrong wiring will cause abnormal works or even damage the electric machine; three-phase water pump can be connected without differentiating cable colors.

  8. A power line can be added with rather distant power supply. Please select proper cable lines according to table to avoid the cable too thin to be abnormal operation.

220-240V… 50/60Hz

Single Phase Motor| Cable Length/Cross-sectional Area Of Conductor( mm 2 )
---|---
kW| 0-15m| 16-30m| 31-45m| 46-60m| 61-75m| 76-90m
0.25| 0.75| 0.75| 0.75| 0.75| 1.0| 1.25
0.37| 0.75| 0.75| 0.75| 1.0| 1.25| 1.25
0.55| 0.75| 0.75| 1.0| 1.25| 1.25| 1.5
0.75| 0.75| 1.0| 1.25| 1.25| 1.5| 1.5
0.92| 1.0| 1.25| 1.25| 1.5| 1.5| 2.0
1.1| 1.0| 1.25| 1.5| 1.5| 2.0| 2.0
1.5| 1.25| 1.5| 2.0| 2.0| 2.5| 2.5
1.8| 1.5| 2.0| 2.0| 2.5| 2.5| 3.0
2.2| 1.5| 2.0| 2.5| 2.5| 3.0| 4.0
2.6| 2.0| 2.5| 2.5| 3.0| 4.0| 4.0
3.0| 2.0| 2.5| 3.0| 4.0| 4.0| 5.0

115V… 60Hz

Single Phase

Motor

| Cable Length/Cross-sectional Area Of Conductor( mm 2 )
---|---
kW| 0-15m| 16-30m| 31-45m| 46-60m| 61-80m| 81-100m
0.18| 0.6| 0.75| 1.0| 1.25| 1.5| 2.0
0.25| 0.75| 1.0| 1.25| 1.5| 2.0| 2.5
0.37| 1.0| 1.25| 1.5| 2.0| 2.5| 3.0
0.55| 1.0| 1.5| 2.0| 2.5| 3.0| 4.0
0.75| 1.25| 2.0| 2.5| 4.0| 5.0| 6.0
1.1| 1.5| 2.5| 4.0| 5.0| 6.0| 8.0
1.5| 2.5| 4.0| 5.0| 6.0| 8.0| I

To choose the required cutting area of cable according to the power of pump and length of external cable to ensure the normal operation of motor.

Please operate as below instructions for adding cable lines:

  1. Strip a 50-60mm cable with a wire stripper, then strip the rubber hose to reveal a 20-30mm copper wire.

  2. Tighten two cable lines with the same color into spiral shape so as to guarantee close connection;

  3. Tightly wind and cover the cable with the electrical insulating tape from the 15-20mm core cord.

  4. Wrap the cable that is covered with the electrical insulating tape with a waterproof adhesive tape from the 20-30mm core cord. The waterproof adhesive tape should be 10mm longer than the electrical insulating tape at both ends. Before the wrapping, the waterproof tape should be stretched out 1-fold its length and follow the normal use.

  5. Wrap the cable that is wrapped with the waterproof adhesive tape with the electrical insulating tape.

  6. Wrap the cable that is wrapped with the electrical insulating tape with the waterproof adhesive tape. The waterproof adhesive tape should be 10mm longer than the electrical insulating tape at both ends. Before the wrapping, the water proof tape should be stretched out 1-fold its length and follow the normal use.

  7. lmmerge the junction of the cable into water for 12 hours. Test the insulation resistance of the
    cable with a 500V megohmmeter. The cold insulation resistance should be no less than 50 MO

  8. The delivery pipe shall be matched to the water outlet ( the specification shall be selected based on the performance parameter table). For example, the iron wire or clamp can be used to connect with soft delivery pipes; the screwed joint can be used for steel delivery pipes for further reliable connection. Further, the threading ropes are used at the handle in case that the rope floats in the water. The tied ropes of hoisting electric pump must be firm and durable. The cable lines shall not be stretched but in a natural loose state.

  9. The cables are not allowed for impact and crushing or used as lifting ropes. Further, do not pull the cables randomly at operation so as to avoid electric shock caused by cable damage.

  10. The depth of electric pump in the water shall not be over 80m but 3m above the bottom. Further, the electric pump shall not be sunk into soils. Meanwhile, the user shall prevent sundries to block nets or impellers, because it will lead to abnormal works. Please check the water level during works to avoid exposed or dry works, or else it will burn the electrical machine and other parts.

  11. During usage, washing, swimming or animals are not allowed within working regions. The safety warning label ” electric shock risk, no entry ” shall be set up on the site to prevent accidents.

  12. The oil-filled electrical machine has been filled with appropriate food machine oil at the time of ex-factory. The users are not allowed to fill in any water or oil into the electrical machine (except for maintenance).

  13. The oil-filled electrical machine is filled with food machine oil that may be leaked when it is damaged or break down. Under the use applications such as planting, cultivation or the transportation and processing of drinking water and food, etc, the leaked food machine oil may cause certain damage to plants and cultured animals or pollute drinking water or food. The user shall evaluate the use environment as well as related consequence before selecting this product so as to confirm its proper use. If necessary, please invite some related professional personnel. If there has food machine oil leakage, please stop using and deal with it properly.

  14. The power source shall be cut off at the time of adjusting position or contacting with electric pumps in case of any accidents. The electric pump shall not be lifted away from water surface before shunting down power source so as to guarantee safety.

  15. The electric pump belongs to specialized technology-based product. The unqualified repairman shall not conduct any randomly disassemble. The sealing and insulation testing must be conducted after laid-up and reassembly.

  16. The maintenance shall be conducted on electric pumps after 3,000 hours normal operation. The maintenance shall be conducted on electric pumps after 3,000 hours normal operation. Various easily damaged parts such as mechanical seal, bearing, impeller, and so on must be replaced. The air pressure test must be conducted on motor and oil chambers after laid-up or changing mechanical seal. The test pressure is 0.4 Mpa. There shall be no leakage within five minutes.

  17. The pump shall not be sunk into water for long-term nonuse. Instead, the pump shall be put in the clear water for several minutes of operation so as to clean mud and other dirties inside and outside of the pump. Further, the anti-rust oil shall be coated on the pump, then it shall be put in a dry and ventilated place. The electric pump with rather long-term use shall be repainted or treated by anti-rust oil according to its surface corrosion status.

Wiring Diagram

VEVOR-3SDM2-21-Deep-Well-Submersible-Pump-01 \(11\)

TECHNICAL DATA

Model| Voltage| Output Power| | Max.head| Power cord length| Max.liquid temperature
---|---|---|---|---|---|---
3SDM2/21| 230V~ 50Hz| 0.55kW| 50L/min| 89m| 20m| +35℃
3SDM4/16| 230V~ 50Hz| 0.75kW| 100L/min| 66m| 20m| +35℃
3.5SDM4/11| 230V~ 50Hz| 0.75kW| 105L/min| 62m| 20m| +35℃
4SDM4/6| 230V~ 50Hz| 0.37kW| 110L/min| 44m| 20m| +35℃
4SDM8/9| 230V~ 50Hz| 1.1kW| 190L/min| 57m| 20m| +35℃
Model| Voltage| Output Power| | Max.head| Power cord length| Max.liquid temperature
---|---|---|---|---|---|---

4SSM4/5

| 115V~ 60Hz|

0.5HP (0.37kW)

|

105L/min

|

51m

|

10m

|

+35℃

230V~ 60Hz
4SSM5/6| 115V~ 60Hz| 1HP (0.75kW)| 140L/min| 63m| 10m| +35℃
230V~ 60Hz
4SSM5/8| 115V~ 60Hz| 1.5HP (1.1kW)| 140L/min| 84m| 10m| +35℃
230V~ 60Hz
4SSM5/12| 230V~ 60Hz| 2HP(1.5kW)| 140L/min| 130m| 10m| +35℃
4SSM5/18| 230V~ 60Hz| 3HP(2.2kW)| 140L/min| 195m| 10m| +35℃

FAILURE REASONS AND TROUBLESHOOTING METHOD

Fault phenomenon Reasons Solutions
Motor: out of operation
  1. Too much low voltage leads
  2. Stuck impeller or stator and rotor;
  3. Power off
  4. The welding lines of capacitor and protector fall
  5. Burnt stator winding or open circuit.

|

  1. adjustment;
  2. Take off the water inlet valve to clean stoppers of impellers as well as silt of sand-proof cover;
  3. Check causes and then take the corresponding measures;
  4. Re-weld falling wires or change
  5. Send to maintenance unit to replace or repair windings.

No water or no enough water amount|

  1. Too much low voltage leads to no enough rotation or reduced water amount;
  2. Too high lift that has exceeded electric pump’s lift capacity;
  3. The strainer or impeller is blocked
  4. Serious wear of impellers;
  5. Open circuit of stator winding.

|

  1. Adjust voltage;
  2. Decrease lift or buy another electric pump according to practical situation;
  3. Clean blocked sundries;
  4. Change impeller or send it to maintenance unit;
  5. Send it to maintenance unit for

Frequently worked protectors|

  1. Too much low voltage leads to increased current and serious motor heating;
  2. Too much low lift leads to increased water drainage and serious motor overload;
  3. Abnormal wear of rotors or
  4. The electric pump is exposed above water or operated in a
  5. Damaged sealing; water
  6. Serious bearing wear (loudly noise) and increased friction force.

|

  1. Adjust voltage;
  2. Use iron wire to narrow water
  3. Reduce installation height; the electric machine;
  4. Replace bearing.

Disposal: This product is subject to the provision of european Directive 2012/19/EC. The symbol showing a wheelie bin crossed through indicates that the product requires separate refuse collection in the European Union. This applies to the product and all accessories marked with this symbol. Products marked as such may not be discarded with normal domestic waste, but must be taken to acollection point for recycling electrical and electronic devices.