Product Introductions
ThermElc TE-03 TH is used for monitoring temperature and humidity of the sensitive goods during storage and transpo- rtation. After the recording is finished, the ThermElc TE-03 TH is connected to any USB port and automatically generates a PDF & CSV report with the temperature and humidity logging results. No additional software is required to read out the ThermElc TE-03 TH.
Main Feature
- Multiple use temperature & humidity logger
- External sensor and bracket
- Auto generates PDF reports
- Auto generates CSV reports
- Logging of 34560 points
- Recording Interval of 10 seconds to 99 hours
- No special device driver required
- Temperature and humidity over-limit alarm
Quick Start
Quick Start ThermElc TE-03 ETH
-
Software Downloadhttps://www.thermelc.com/pages/download
-
Press start 3 seconds
-
Measure Monitoring
-
Read
USB -
Report Auto PDF. CSV Report Data & Graphic Comparison Available
Configuration of ThermElc TE-03 TH
The device can be configured using the free data managem- ent software.
1 | Time zone: | UTC |
---|---|---|
2 | Temperature scales: | °C /°F |
3 | Screen display: | Always on/ Timed |
4 | Start delays: | 0/timed (30min default) |
5 | Start delays: | 0/ timed |
6 | Stop mode: | Press button/ disabled |
7 | Start mode: | Press button or Timed |
8 | Temperature and humidity over-limit alarm | |
9 | Alarm setting: | Upper Limit and Lower Limit |
140 | FDA Module: | To enable in settings |
Operation Functions
-
Start Recording
Press and hold the START button for approximately 3sec.The OK light is on and the ( ) or (WAIT) on screen indicates the logger is started. -
Mark
When the device is recording, press and hold the START bu- tton for more than 3sec, and the screen will switch to the “MARK” interface. The number of MARK’ will increase by one, indicating data was marked successfully. -
Stop Recording
Press and hold the STOP button for more than 3sec until the STOP ( ) symbol displays on the screen, indicating stopping recording successfully. -
Switch the display
Shortly press START button to switch to different display int- erface. The interfaces shown in sequence are respectively: Real-time Temperature > Real- time Humidity > LOG > MARK > Temperature Upper Limit > Temperature Lower LimitHumidity Upper Limit > Humidity Lower Limit.
-
Get Report
Connect the data logger to PC via USB, and it will auto-gen- erate PDF and CSV reports.
LCD Display Descriptio
| Data logger is recording
---|---
| Data logger has stopped recording
WAIT| Data logger is in Start Delay status.
| Temperature and Humidity is within the limited range
| Measured value exceeds its upper limit
| Measured value exceeds its lower limit
Battery Replacement
Technical Support | Video Instruction |
---|---|
![ThermElc TE-03 ETH Temperature Humidity Data Logger - QR Code |
2](https://manuals.plus/wp-content/uploads/2023/11/ThermElc-TE-03-ETH- Temperature-Humidity-Data-Logger-QR-Code-2.jpg)
<https://thermelc.com/pages/support>
|
<https://www.youtube.com/channel/UCVcVdaeDAISsSzAxqYYj_jw>
https://www.thermelc.com
sales@thermelc.com
+44 (0)207 1939 488
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>