REGENCY HI2450 Wood Fireplace Insert Instruction Manual

June 14, 2024
Regency

Hampton™
HI2450 Wood
Fireplace InsertREGENCY HI2450 Wood Fireplace
Insert Owners & Installation Manual

HI2450 Wood Fireplace Insert

Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Thank you for purchasing a
REGENCY FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
“This wood heater has a manufacturer set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.”
Failure to follow the manual details can lead to smoke and CO emissions spilling into the home. It is recommended to have monitors in areas that are expected to generate CO such as heater fueling areas.
“U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission standards using cord wood.”
Tested & listed to ASTM E3053. Model Regency HI2450 1.4g/hr.
“This manual describes the installation and operation of the Regency HI2450 wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s cord wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 14,200 Btu/hr. to 34,600 Btu/hr.” Efficiency is determined using the B415 method resulting in lower and higher heat values. This heater generates the best efficiency when operated using well-seasoned wood and installed in the main living areas where the majority of the chimney is within the building envelope. ”
It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual, or if elements are deactivated or removed.”
CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS, COAL, PLASTIC,GARBAGE, SULPHUR OR OIL MAY DAMAGE THE HEATER.
“This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods.”
DO NOT BURN:

  • Treated wood
  • Coal
  • Garbage
  • Cardboard
  • Solvents
  • Colored Paper
  • Trash
  • Lawn clippings or yard waste
  • Materials containing rubber including tires
  • Materials containing plastic
  • Waste petroleum products , paints or paint thinners or asphalt products
  • Materials containing asbestos
  • Construction or demolition debris
  • Railroad ties
  • Manure or animal remains
  • Saltwater driftwood or other previously salt water saturated materials
  • Unseasoned wood
  • Paper products, cardboard, plywood or particle board. The prohibition against burning these materials does not prohibit the use of fire starters made from paper, cardboard, saw dust, wax and similar substances for the purpose of starting a fire in a wood heater.

Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.
The authority having jurisdiction (such as Municipal Building Department, Fire Department, Fire Prevention Bureau, etc.) should be consulted before installation to determine the need to obtain a permit.
This unit must be connected to either a listed factory built chimney suitable for use with solid fuels and conforming to, ULC629 in Canada or UL103HT in the United States of America. or code approved masonry chimney with flue liner.
HI2450 is tested and certified to ULC-S628-93 (R1997) and UL1482-2011 (R2015).
SAVE THESE INSTRUCTIONS WARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov
CAUTION: To avoid burns or wood splinters, when opening/closing the fuel door or adding wood to the fire, You should always wear appropriate protective gloves to protect your hands from the heat being emitted from this fireplace.

Safety decal

This is a copy of the label that accompanies your Regency Insert. We have printed a copy of the contents here for your review.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
LISTED FACTORY BUILT FIREPLACE INSERT
CERTIFIED FOR USE IN CANADA AND U.S.A.
Serial No./ 523
DO NOT REMOVE THIS LABEL
U.S. ENVIRONMENTAL PROTECTION AGENCY CERTIFIED TO COMPLY WITH 2020 PARTICULATE EMISSION STANDARDS USING CORD WOOD.” TESTED & LISTED TO ASTM E3053.
MODEL REGENCY HI2450 1.4G /HR. THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL. COMPONENTS REQUIRED FOR INSTALLATION: 5.5″ (140mm) or 6″ (152mm) STAINLESS STEEL LINER INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY IN MASONRY FIREPLACE OR FACTORY BUILT FIREPLACE. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA
FLOOR THERMAL INSULATION/PROTECTION WITH A R VALUE OF 1.4 IS REQUIRED IF THE UNIT IS RAISED 0 – 2.5″ (64MM) (MEASURED FROM THE BOTTOM OF THE APPLIANCE).
THERMAL FLOOR PROTECTION IS NOT REQUIRED WHEN UNIT IS RAISER GREATER THAN 2.5″ (64MM) (MEASURED FROM THE BOTTOM OF THE APPLIANCE).
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY OPTIONAL COMPONENT: FAN (300-911/915), ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE.
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. OPEN FEED DOOR TO FEED FIRE ONLY. REPLACE GLASS ONLY WITH CERAMIC GLASS (5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING
CAUTION HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHINGANDFURNITUREAWAY. CONTACTMAYCAUSESKINBURNS.
READ ABOVE INSTRUCTIONS.
SURFACES CHAUDESLORS DEFONCTIONNEMENT
Manufactured
LTD. INTERNATIONAL PRODUCTS FIREPLACE
1H4 V4G BC DELTA, ST., VENTURE 6988
MADE IN CANADA (Duplicate Serial#) 523

Dimensions

Dimensions with Regular FaceplateREGENCY HI2450 Wood Fireplace Insert -
Faceplate ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY.
ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS.
Dimensions with Oversize Faceplate![REGENCY HI2450 Wood Fireplace Insert

Installation

Unit Hi2450| Adjacent
Side Wall
(to Side) A| Mantle *
(to Top of Unit) B| Top Facing (to Top of Unit) C| Side Facing D| Minimum Hearth
Extension
E| Minimum
Hearth
Thickness F| Minimum
Hearth Side
Extension* G| To Top of
Unit H
---|---|---|---|---|---|---|---|---

| 12″ (305 mm)

| 14″(356 mm) for 3-1/2″ (89 mm) mantel| 14″ (356 mm)

| 1/2″ (13 mm)
to side surround| 16″ (406 mm) USA| 1/2″(13 mm)

| 8″ (203 mm)

| 21-5/8″
(548 mm)

Side and Top facing is a maximum of 1-1/2″ (38mm) thick. Clearances are critical.
Mantel can be installed anywhere in shaded area or higher using the above scale.
Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour.
Wood Insert Specifications
Your fireplace opening requires the followingminimum sizes:
Height: 21.5″
Width: 25″
Depth: 17″
Two faceplates are available to seal the fireplace opening:
Standard
40″ W x 30″ H (narrowest point)
42-1/2″ W x 30″ H (widest point)
Oversize
** 48″ W x 34-9/16″ H
51-7/8″ W x 34-9/16″ HREGENCY HI2450 Wood Fireplace Insert - dimensions
1 *Floor Protection
Floor thermal insulation/protection with a R value of 1.4 is required if the unit is raised 0 – 2.5″ (0-64mm) (measured from the bottom of the appliance).
Thermal floor protection is not required when unit is raiser greater than 2.5″ (64mm) (measured from the bottom of the appliance).
Please check to ensure that your floor protection and hearth will meet the standards for clearance to combustibles. Your hearth extension must be made from a non-combustible material. Extending 16″ for US and 18″ for Canada—measured from the fuel loading door opening.
Installation into a Masonry Fireplace
Regency Inserts are constructed with the highest quality materials and assembled under strict quality control procedures that insure years of trouble free and reliable performance.
It is important that you read this manual thoroughly and fully understand the safe installation and operating procedures. The more you understand the way your Regency Insert operates, the more enjoyment you will experience from knowing that your unit is operating at peak performance.
Before Installing Your Insert

  1. Please read this entire manual before you install and use your new wood insert.
    Failure to follow instructions may result in property damage, bodily injury or even death. Install and use only in accordance with manufacturer’s installation and operating instructions.

  2. Check your local building codes – Building Inspection Department. You may require a permit before installing your insert. Be aware that local codes and regulations may override some items in the manual.
    WARNING: Careless installation is the major cause of safety hazard. Check all local building and safety codes before installation of unit.

  3. Notify your home insurance company that you plan to install a fireplace insert or hearth heater.

  4. Your fireplace insert is heavy and requires two or more people to move it safely. The insert can be badly damaged by mishandling.

  5. If your existing fireplace damper control will become inaccessible once you have installed your Regency Insert, you should either remove or secure it in the open position.

  6. Inspect your fireplace and chimney prior to installing your insert to determine that it is free from cracks, loose mortar or other signs of damage. If repairs are required, they should be completed before installing your insert. Do not remove bricks or mortar from your masonry fireplace.

  7. Do not connect the insert to a chimney system servicing another appliance or an air distribution duct.

When referencing installation or connection to masonry fireplaces or chimneys, the masonry construction must or shall be code complying.
Chimney Specifications
Before installing, check and clean your chimney system thoroughly. If in doubt about its condition, seek professional advice. Your Regency Insert is designed for installation into a masonry fireplace that is constructed in accordance with the requirements of “The Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliance”, N.F.P.A. 211, the National Building Code of Canada, or the applicable local code requirements.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.
Regency Inserts are designed to use either a 5.5″ (140mm) or 6″ (152mm) flue.
In Canada this fireplace insert must be installed with a continuous chimney liner of 5.5″ (140mm) or 6″ (152mm) diameter extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of CAN/ULC-S635 or CAN/ ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
In the U.S.A., a 5.5 inch (140 mm) or 6 inch (152 mm) diameter, stainless steel, full height chimney liner that meets type HT (2100° F) requirements per UL 1777 must be installed. The full liner must be attached to the insert flue collar and to the top of the existing masonry chimney.
Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance and may cause damage. An uncontrollable burn or excessive temperature indicates excessive draft. Inadequate draft may cause back puffing into the room and plugging of the chimney. Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints. Ensure the heater is installed in areas that are not too close to neighbors or in valleys that would cause unhealthy air quality or nuisance conditions. Optional Flue Connector Kit
The Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your flue connector and the insert collar.
Detailed installation instructions are included with the kit.
The following may also be purchased separately if required to complete the install:
846-506 6″ Flue Adapter 30 degree
846-508 6″ Flue Adapter 45 degree
948-412/P 6″ Flue Offset Adapter (offsets back 4″)
846-527 Flue Connector Kit Installation Into a Factory Built Fireplace
Regency inserts are constructed with the highest quality materials and assembled under strict quality control procedures that ensure years of trouble free and reliable performance.
It is important that you read this manual thoroughly and fully understand the installation and operating procedures. Failure to follow instructions may resultin property damage, bodily injury or even death. Themore you understand the way your Regency Insert operates, the more enjoyment you will experience from knowing that your unit is operating at peak performance.
Requirements for Installing Solid-fuel Inserts in Factory-built Fireplaces

  1. A permit may be required for installations, final approval is contingent of the authority having local jurisdiction. Consult insurance carrier, local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.
  2. Inspect the existing fireplace and chimney for any damage or flaws such as burnouts, metal or refectory warping.
  3. Inspection to a minimum of NFPA 211 Level II is recommended. All repairs must be made prior to installing an insert. The fireplace must be structurally sound and be able to support the weight of the solid-fuel insert.
  4. The factory-built chimney must be listed per UL 127 or ULC 610-M87 for all installations. Install thermal protection as per this appliance listing requirements.
  5. A full height 5.5 inch (140 mm) or 6 inch (152 mm) diameter stainless steel full height listed chimney liner must be installed meeting type HT (2100°  F) requirements per UL 1777 (USA) or ULC S635 with ”0” clearance to masonry (Canada). The full liner must be attached to the insert flue collar and to the top of the existing chimney.
  6. The flue liner top support attachment must not reduce the air flow for the existing air-cooled chimney system. Reinstall original factory-built chimney cap only.
  7. To prevent room air passage to the chimney cavity of the fireplace, seal either the damper area around the chimney liner or the insert surround. Circulating air chamber (i.e. in a steel fireplace liner or metal hearth circulatory) may not be blocked. The air flow within and around the fireplace shall not be altered, blocked by the installation of the insert (i.e. not louvers or cooling air inlet or outlet ports may be blocked by the insert or the insert surround).
  8. Means must be provided for removal of the insert to clean the chimney flue.
  9. Inserts that project in front of the fireplace must be supplied with appropriate supporting means.
  10. Installer must mechanically attach the supplied label to the inside of the firebox of the fireplace into which the insert is installed.

WARNING

Fire Risk.
When lining air-cooled factory-builchimneys:
– Run chimney liner approved to
UL 1777 Type HT requirements (2100° F)
– Reinstall original factory-built chimney cap ONLY
– DO NOT block cooling air openings in chimney
– Blocking cooling air will overheat the chimney
Altering the Fireplace
The following modifications of factory-built fireplaces are permissible:
The following parts may be removed:

Damper Smoke Shelf or Baffle
Ember Catches Fire Grate
Viewing Screen/ Curtain Doors

– The fireplace must be altered. Cutting any sheet metal parts of the fireplace in which the fireplace insert is to be installed is prohibited, except that the damper may be removed to accomodate a directconnect starter pipe or chimney liner.
– External trim pieces which do not affect the operation of the fireplace may be removed providing they can be stored on or within the fireplace for reassembly if the insert is removed.
– The permanent metal warning label provided in the component pack must be attached to the back of the fireplace, with screws or nails, stating that the fireplace may have been altered to accomodate the insert, and must be returned to original condition for use as a conventional fireplace.
– If the hearth extension is lower than the fireplace opening, the portion of the insert extending onto the hearth must be supported.
– Manufacturer designed adjustable support kit can be ordered from your dealer.
– Final approval of this installation type is contingent upon the authority having jurisdiction.
WARNING: This fireplace may have been altered to accommodate an insert. It must be returned to its original condition before use as a solid fuel burning fireplace.

  1. When installed in a factory built fireplace, a full stainless steel rigid or flexible flue liner is mandatory, for both safety and performance purposes. When a flue or liner is in use, the insert is able to breathe better by allowing a greater draft to be created. The greater draft can decrease problems such as, difficult startups, smoking out the door, and dirty glass.

  2. In order to position the flue liner, the existing rain cap must be removed from your chimney system. In most cases the flue damper should also be removed to allow passage of the liner.

  3. In most cases opening the existing spark screens fully should give enough room for the insert installation. If it does not, remove and store.

  4. If the floor of your fireplace is below the level of the fireplace opening, adjust the insert’s levelling bolts to accommodate the difference.
    When additional shimming is required, use non-combustible masonry or steel shims.

  5. Measure approximately the alignment of the flue liner with the position of the smoke outlet hole on the insert to check for possible offset.
    If an offset is required, use the appropriate offset adaptor in your installation.

Draft
Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance and may cause damage. An uncontrollable burn or excessive temperature indicates excessive draft. Inadequate draft may cause back puffing into the room and plugging of the chimney. Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints. Ensure the heater is installed in areas that are not too close to neighbors or in valleys that would cause unhealthy air quality or nuisance conditions.
STOP! PLEASE READ CAREFULLY.
CAST COMPONENTS ARE VERY FRAGILE.
USE EXTREME CARE WHEN HANDLING.
Installing Your Insert
Your insert is very heavy and will require two or three people to move it into position.

  1. Remove the door to make the insert easier to handle. To remove the Door, open fully and lift it up off its hinges.
    Refer to the Door Removal section for an important note on installation.REGENCY HI2450 Wood Fireplace Insert - Chimney
3

  2. NOTE: For Masonry installation make sure that the firebox is level with the hearth using non-combustible materials and no more than 1/2 to 1 inch of the levelling bolt.

  3. Lift the unit up onto the Hearth and slide into the fireplace opening.
    Be sure to leave the unit out at least 3 to 4 inches in order to make the necessary flue connections and to install the faceplate. Be sure to protect your hearth extension during the installation, ie. with a heavy blanket.

WARNING
DO NOT LIFT OR PUSH THE UNIT FROM THE ASHLIP, LEFT SIDE CAST or RIGHT SIDE CAST.
THE CASTING WILL CHIP OR BREAK. Stainless Steel Smoke Deflector Installation
The stainless smoke deflector is located in the upper front area of the firebox. The deflector is held in place with 2 bolts Prior to the first fire, ensure deflector is seated properly and secured with 2 hand tightened bolts.REGENCY HI2450 Wood Fireplace Insert -
InstallationTo replace the deflector, loosen off both bolts and slide deflector upward and out. Install new deflector and hand tighten bolts. Ensure positive location of the deflector prior to hand tightening.
WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty.REGENCY HI2450 Wood Fireplace Insert -
Installation 1 Standard Cast Faceplate Installation

FACEPLATE CONTENTS LIST


Qty| Description
1| Left Side Faceplate
1| Right Side Faceplate
1| Top Faceplate
2| Side Mounting Brackets
4| 1/4″ – 20 x 1/2″ Hex Head Bolts
4| 1/4″ Lock Washers
4| 1/4″ Flat Washers
2| 47″ Insulations

  1. Secure the Side Mounting Brackets (packaged with Faceplate) to the left and right side of the fi rebox using 4 bolts per mounting bracket as shown in the diagram below.REGENCY HI2450 Wood Fireplace Insert - Installation 3

  2. Secure the Left and Right Side Faceplate to the fi rebox by aligning the Mounting Holes with the Side Mounting Brackets taking care to align vertically while each side rests on the hearth. Secure using 1 bolt per bracket.REGENCY HI2450 Wood Fireplace Insert - Installation 4

  3. Place Mantel To p onto the top of the fi rebox. With the Mantel Top in place check to make sure there is no gap between the nut retainer and the underside cast of the Mantel Top. If there is a gap present you will need to lower that side cast by loosening 2 bolts, see step 6 for bolt location (check to see if level).

  4. Slowly slide the Mantel Top forward until it stops.REGENCY HI2450 Wood Fireplace Insert - Installation 6

  5. Mount the Top Faceplate by carefully sliding the Mounting Plates on the Left and Right Side Faceplate thru the Retainers in the Top Faceplate.
    NOTE: Slowly lower the Top Faceplate into position; being careful not to damage the Mantel Top.

  6. If unable to align side faceplate to unit and top faceplate further adjustments need to be made, complete one side at a time. Loosen all bolts on brackets (6 per side).
    Loosen top and bottom bolts (Shown below).
    Adjust left or right side cast plates to allow further adjustment on faceplate. Once aligned, hold side surround in place and tighten all bolts. If side cast height needs adjusting, loosen 2 bolts holding cast bracket and adjust up or down.REGENCY HI2450 Wood Fireplace Insert - Installation
7See Step 3 to identify side casts.
    See next page for recommended measurements.REGENCY HI2450 Wood Fireplace
Insert - Installation 8

  7. Carefully slide the Mantel To p back into position.REGENCY HI2450 Wood Fireplace Insert - Installation 9

  8. Location of Insulation:
    a) Place 1 piece of Insulation behind the Mantel Top.
    b) Cut the second piece of Insulation in half, then install behind both the Left and Right Sides as shown.REGENCY HI2450 Wood Fireplace Insert -
Installation 10

  9. The unit may now carefully be slid into fi nal position.

RECOMMENDED MEASUREMENTS FOR SETTING SIDE CASTS
Stop! Read Carefully.
Enamel & Cast components are very fragile.
Use extreme care when handling.REGENCY HI2450 Wood Fireplace Insert -
Installation 11REGENCY HI2450 Wood
Fireplace Insert - Installation 124-1/2″ – 4-3/4″ boths sides rear inside edge to fi rebox.
Important: Verify gap between cast and door did not change when rear adjustments have been made.
Carefully open door slowly, to ensure that the door does not rub against cast sides.

  • These are just recommended measurements.
    Oversize Cast Faceplate Installation
    Stop! Read Carefully.
    Enamel & Cast components are very fragile. Use extreme care when handling.

FACEPLATE CONTENTS LIST


Qty| Description
­1| Left Side Faceplate
­1| Right Side Faceplate
­1| Top Faceplate
2| Side Mounting Brackets
2| 1/4″ – 20 x Hex Nuts
2| 1/4″ – 20 x 1″ Hex Head Bolts
2| 1/4″ Flat Washers
2| 47″ Insulations
­1| 8mm gasket

  1. Secure the Side Mounting Brackets (packaged with Faceplate) to the left and right side of the fi rebox using 2 bolts per mounting bracket as shown in the diagram below. Bolts are pre-installed on unit.
    Leave bolts loose until fi nal adjustment is made.

  2. Secure the Left and Right Side Faceplate to the fi rebox by aligning the Mounting Holes with the Side Mounting Brackets taking care to align vertically while each side rests on the hearth. Secure using 2 bolts per bracket.REGENCY HI2450 Wood Fireplace Insert - Installation 14

  3. Place 1/4″ x 1″ Hex head bolt with 2 washers in Mantel Top Spacer locations shown below.

  4. Place Mantel Top onto the top of the fi rebox.REGENCY HI2450 Wood Fireplace Insert - Installation 15With the Mantel Top in place check to make sure there is no gap between the Mantel To p Spacer and the underside cast of the Mantel Top. If there is a gap present you will need to lower that side cast by loosening 2 bolts, see side cast adjustment section for bolt location (check to see if level).

  5. Slowly slide the Mantel Top forward until it stops.REGENCY HI2450 Wood Fireplace Insert - Installation 16

  6. Place supplied gasket to bottom edge of top faceplate – continue gasket up each side at a 45° angle.

  7. Mount the Top Faceplate by carefully sliding the Mounting Plates on the Left and Right Side Faceplate through the Retainers in the Top Faceplate.
    NOTE: Slowly lower the Top Faceplate into position; being careful not to damage the Mantel Top.
    NOTE: Installing the top faceplate will require 2 people – it is heavy and awkward to handle.REGENCY HI2450 Wood Fireplace Insert - Installation
17

  8. Carefully slide the Mantel To p back into position.REGENCY HI2450 Wood Fireplace Insert - Installation 18

  9. Adjust Left Side Faceplate and tighten bolts. Repeat step for Right Side Faceplate.

  10. Location of Insulation:
    a) Place 1 piece of Insulation behind the Mantel Top.
    b) Cut the second piece of Insulation in half, then install behind both the Left and Right Sides as shown.REGENCY HI2450 Wood Fireplace Insert -
Installation 19

  11. The unit may now carefully be slid into fi nal position.
    See side cast adjustments if faceplate needs aligning.

SIDE CAST ADJUSTMENTS
If unable to align side faceplate to unit and top faceplate further adjustments need to be made, complete one side at a time. Loosen all bolts on brackets (6 per side). Loosen top and bottom bolts (Shown below).
Adjust left or right side cast plates to allow further adjustment on faceplate. Once aligned, hold side surround in place and tighten all bolts. If side cast height needs adjusting, loosen 2 bolts holding cast bracket and adjust up or down. REGENCY HI2450 Wood Fireplace Insert -
ADJUSTMENTSRECOMMENDED MEASUREMENTS FOR SETTING SIDE CASTS
Stop! Read Carefully.
Enamel & Cast components are very fragile.
Use extreme care when handling.REGENCY HI2450 Wood Fireplace Insert -
ADJUSTMENTS 1REGENCY HI2450 Wood Fireplace
Insert - ADJUSTMENTS 2Important: Verify gap between cast and door did not change when rear adjustments have been made.
Carefully open door slowly, to ensure that the door does not rub against cast sides.

  • These are just recommended measurements.
    GLASS REMOVAL TO INSTALL OPTIONAL DOOR CAST GRILL

    1. To remove the glass, loosen the two 7/16″ bottom retainer bolts but do not remove.
    2. Remove the sides and top retainer and bolts highlighted in the diagram and carefully remove glass, it will fall towards you at the top.
    3. Place the grill in the door, make sure that the glass gasketing on the left and right bracket is facing you.
    4. Carefully place the glass (black strip up) into the bottom re- tainer. Keeping it in place, re-install the sides and top retainer and bolts. Do not tighten bolts, fi nger tight only.
    5. Lift the bottom of the glass upwards till it stops, secure glass retainer using the 8 bolts. Do not wrench down on the bolts, as this may cause the glass to break.

REGENCY HI2450 Wood Fireplace Insert - Replacement 5 Fan Installation
Installer: Please record unit serial number here before installing blower.
Serial No.__
Your fan should only be installed once the unit is in place in order to prevent any damage to the fan.

  1. Attach the Left and Right Side Fan Facia to the Front Fan Facia by aligning the Side Facia screw slots with the hole locations in the Front Fan Facia and secure using 2 screws per side.REGENCY HI2450 Wood Fireplace Insert - ADJUSTMENTS 4

  2. Once the Fan Facia has been assembled carefully slide the Fan into position by centering the Fan below the Ashlip and align the Fan Support Clips with the Offset Clips under the Ashlip.
    Note: The Draft Control Rod is to fit through the top opening in the Switch Plate.REGENCY HI2450 Wood Fireplace Insert - ADJUSTMENTS
5 IMPORTANT
    Ensure that the Left and Right Side Fan Facia do not hit the sides of the Faceplate when sliding the Fan into position as the casting may chip.
    If the spacing between the Side Fan Facia and the Faceplate requires adjustment, the Side Fan Facia’s can be slightly pushed in or pulled out to fit accordingly.REGENCY HI2450 Wood Fireplace Insert - ADJUSTMENTS
6

  3. Ensure the power cord and all other wires will not come into contact with any hot stove surfaces.

DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF UNIT.
Do not turn the fan ON until your insert has reached operating temperature or at least 30 minutes after starting fire.![REGENCY HI2450 Wood Fireplace Insert

  • ADJUSTMENTS 7](https://manuals.plus/wp-content/uploads/2023/11/REGENCY- HI2450-Wood-Fireplace-Insert-ADJUSTMENTS-7.png) Power Outlet Conversion

    1. Remove the Phillips screw, located on the top of the fan housing, which attaches the fan defl ector to the main fan body.

    2. Take off the 2 screws from the fan switch plate assembly, and remove it from the left casting face.REGENCY HI2450 Wood Fireplace Insert - Conversion 1

    3. Take off the 2 bolts, nuts, and washers from the thermodisc assembly, and remove it from the main fan body. Retain the screws for reattachment on the other side.

    4. Remove the green ground wire from the left side of the fan motor, by detaching the phillips screw. Keep the screw to reattach the green ground wire on the other side.

    5. Raising the fan defl ector, pull the wire harness, switch plate, ground wire and thermodisc assembly from the left side and relocate to the right side of the main fan housing. See step 10 for Thermodisc Assembly installation.
      Important Note:
      The wire harness may be tight between the fan motor and main body but will move over and down to the base with a little fl exing of the fan motor. Ensure the wire harness rests on the base when pulled over.

    6. Remove the 2x 7/16″ bolts from the right casting.
      Discard the existing casting plate and attach the new casting plate with the switch plate assembly.

    7. Remove the top black screw from the leg on the right side of the fan motor, and attach the screw to the leg on the left side.REGENCY HI2450 Wood Fireplace Insert - Conversion 4

    8. Attach the green ground wire with the #8 x 3/8″ Pan Head Phillips steel self tapping screw, previously removed from the left side.

    9. Remove the wires one at a time from the existing switch plate, and attach each wire to the new switch plate, each wire in the same position as it was on the old switch plate (see wiring diagram). Discard the old switch plate.
      REGENCY HI2450 Wood Fireplace Insert - Conversion 7

    10. Attach the thermodisc assembly to the mounting holes located on the right side of the base of the main fan body using the existing hardware – 2 bolts, nuts and washers.
      Important Note:
      On older fan units these holes may require drilling. Use template provided to drill holes. Place template by aligning to the right corner of the thermodisc assembly base. See Diagram 1.
      REGENCY HI2450 Wood Fireplace Insert - Conversion 6

    11. Attach the new cover plate to the left side casting using 2x #6 32×3/8″ Pan Head Phillips black screws.
      REGENCY HI2450 Wood Fireplace Insert - Conversion 8

    12. Attach the fan defl ector to the main fan body by replacing the Phillips screw on the top of the fan housing.

Flue Collar Removal and Installation
List of Tools required:

  • Pull rod (supplied with unit)
  • 1/2″ socket / ratchet
  • 3/8″ open face wrench
  • 7/16″ socket / ratchet

NOTE: The removable flue collar is attached to the unit. If you need to remove the collar for ease of installation, please follow the below steps.
Note: unit in images may not be identical to the HI2450—but they depict the process.
SAFETY NOTE: The insert is very heavy and will require two people to move it into position. The door and bricks can be removed to help. Be sure to protect your hearth extension with a heavy blanket or cardboard during the installation.

  1. Allow the stove to burn out and cool down.

  2. Remove stainless steel smoke deflector – See instructions in this manual.

  3. Remove the front 2 secondary air tubes with pliers as shown below.
    REGENCY HI2450 Wood Fireplace Insert - Removal

  4. Remove baffles – push the baffles together and away from the side walls.

  5. Lift the left baffle out from underneath the right baffle – then lift out.
    Remove the right baffle.

  6. Manoeuver the baffle above the air tube and slide out.

  7. Take a ½” ratchet and remove the two bolts at back inside of the firebox.
    These bolts are used to secure the flue collar. Keep these and washers for reinstall.

  8. Slide collar off the unit.

  9. Install flex liner into existing chimney as per liner manufacturer’s specifications. See Diagram 1.

  10. Secure the adaptor to the flex liner with three screws. Ensure the adapter is level and aligned correctly. See Diagram 2.

  11. Install the unit by first setting the rear of the unit into the fireplace. See Diagram 3. Ensure that the unit is centered in the existing fireplace and lined up with the flue adaptor.

  12. Slide the unit back until the flue adaptor is slightly engaged. At this point it is recommended to level the unit. This will keep the adaptor from binding.

  13. Insert the provided pull rod through the hole in the top center of the unit. Secure the threaded end into the flue adaptor as shown in diagram 4. While sliding the unit into place pull on the rod to ensure that the flue adaptor is properly engaged. See Diagram 5. Double check the adaptor is seated properly and the pull rod in the firebox, locate the two holes lined up to the two holes on the adaptor.
    REGENCY HI2450 Wood Fireplace Insert - Removal 8

  14. Use the two bolts, washers and lock washers (supplied in manual pack) and install them, tighten down using the 1/2″ socket to ensure the adapter is positively secured to the unit. Once completed remove pull rod and place away for future reinstall.

  15. Reverse steps 6-3 to complete the installation.

Floor Protection
Please check to ensure that your floor protection and hearth will meet the standards for clearance to combustibles. Your hearth extension must be made from a non-combustible material.

Flue Baffle & Secondary Air Tube Installation
The flue baffle system located in the upper area of the firebox is removable to make cleaning your chimney system easier. The baffles must be installed prior to your first fire. Smoke spillage and draft problems may occur if the baffles are improperly positioned. Check the position of the baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox.
The unit arrives with the 2 baffles and 2 air tubes on the floor of the firebox.

  1. Open the door and remove stainless steel smoke deflector – See smoke deflector instructions in this manual.

  2. Slide the left baffle over the 2 remaining air tubes from the front and then push it to the back.

  3. Tilt the left baffle up on top of the side channel and it will leave enough room to position the right baffle in the same manner as Step 1) above. Then reposition the left baffle flat on the air tubes.
    Important: push both baffles so they are tight against the side walls.

  4. Install the 2 front secondary air tubes with pliers and hammer to lock them into place, as shown below.
    NOTE: If air tube is locked into place correctly there should be slight movement when moving the air tube back and forth.

  5. Reverse Step 1.

Brick Installation
Firebrick is included to extend the life of your stove and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not become misaligned during shipping. Install all firebricks (if bricks were removed at install) per the diagram below and place in their correct positions.
Do not use a grate.
REGENCY HI2450 Wood Fireplace Insert - Secondary 5

Order of firebrick install:
a) Rear Firebrick
b) Firebox floor – install brick over LyTherm Sheet
c) Right and left side Firebricks

180-960 Firebrick – Complete Set
70) 902-111 Brick Regular Full Size: 1-1/4″ x 4-1/2″ x 9″
75) Brick Partial: 1-1/4 x 4-1/2″ x 2″
76)
Brick Partial: 1-1/4″ x 2″ x 9″

REGENCY HI2450 Wood Fireplace Insert - Secondary 6

Seasoned Wood
Whether you burn wood in a fireplace, stove or insert, good quality firewood is the key to convenience, efficiency and safety. Wet wood and pieces that are not the right size and shape for your wood burner can be frustrating, burn inefficiently and deposit creosote that can fuel a dangerous chimney fire. Good planning, seasoning and storage of the firewood supply are essential to successful wood burning.

  • Stack the wood in separate rows in an open location where the summer sun can warm it and breezes can carry away the moisture. Do not stack unseasoned wood tightly in an unvented storage area.
  • Do not allow firewood to lie on the ground for more than a couple of days before stacking. Mould and rot can set in quickly.
  • Stack the wood up off the ground on poles, lumber rails or pallets.
  • The top of the pile can be covered to keep off rain, but do not cover the sides.

Softer woods like pine, spruce and poplar/aspen that is cut, split and stacked properly in the early spring maybe be ready for burning in the fall. Extremely hard woods like oak and maple, and large pieces of firewood, may take a minimum of a full year to dry enough. Drying may also take longer in damp climates
There are a few ways to tell if wood is dry enough to burn efficiently. Use as many indicators as possible to judge the dryness of the firewood your are considering. Here are ways to judge firewood moisture.

  • Using a moisture meter, select the species of fuel and then penetrate the pins into a split piece. Ideal moisture and seasoned firewood should be less than 20% moisture content.
  • Checks or cracks in the end grain can be an indication of dryness, but may not be a reliable indicator. Some wet wood has checks and some dry wood has no checks.
  • The wood tends to darken from white or cream colour to grey or yellow as it dries.
  • Two dry pieces banged together sound hollow; wet pieces sound solid and dull.
  • Dry wood weighs much less than wet wood.
  • Split a piece of wood. If the exposed surface feels damp, the wood is too wet to burn.

Operating Instructions

With your unit now correctly installed and safety inspected by your local authority, you are now ready to start a fire. Before establishing your first fire, it is important that you fully understand the operation of your draft control.

WARNING Fireplace Stoves equipped with doors should be operated only with doors fully closed. If doors are left partly open, gas and flame may be drawn out of the fireplace stove opening, creating risks from both fire and smoke.

Draft Control
Both the primary and air wash drafts are controlled by the control slide located on the front left side of the unit. To increase your draft – slide to the left to open, and to decrease – slide to the right to close.
The HI2450 unit has a secondary draft system that continually allows combustion air to the induction ports at the top of the firebox.
Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance and may damage the unit. Inadequate draft may cause back puffing into the room and plugging of the chimney.

Outward – Open Inward – Closed

Left – Open Right – Closed

WARNING: To build a fire in ignorance or to disregard the information contained in this section can cause serious permanent damage to the unit and void your warranty!

First Fire
When your installation is completed and inspected you are ready for your first fire.
THIS UNIT IS DESIGNED TO BURN SEASONED CORDWOOD ONLY. COAL, BRIQUETTES AND ALL OTHERS LISTED ON PAGE 2 ARE NOT APPROVED. SEASONED CORDWOOD SHOULD BE LESS THAN 20% MOISTURE CONTENT.
START UP AND OPERATING PROCEDURES:

  1. For the first few days, the stove will give off an odour from the paint. This is to be expected as the high temperature paint becomes seasoned. Windows and/or doors should be left open to provide adequate ventilation while this temporary condition exists. Burning the stove at a very high temperature the first few times may damage the paint. Burn fires at a moderate level the first few days.

  2. Do not place anything on the stove top during the curing process. This may result in damage to your paint finish.

  3. During the first few days it may be more difficult to start the fire. As you dry out your firebrick and your masonry flue, your draft will increase.

  4. Open the air control to fully open position (all the way to the left) and open the front fuel door. Load firebox with 1.7lb of kindling and crumpled paper and light crumpled paper to establish fire. DO NOT USE A GRATE TO ELEVATE THE FIRE. CAUTION: Never leave unit unattended if door is left open. This procedure is for fire start-up only, as unit may overheat if door is left open for too long.

  5. Keep the door partially open for approximately 3 minutes and then close door. WARNING: Never build a roaring fire in a cold wood insert. Always warm your wood insert up slowly!

  6. Once most of the kindling has burned down, add more kindling and a few bigger pieces of startup wood split approximately 2 inches thick. Keep the door open until flames are reestablished.

  7. When a good fire is established, add 8-10 more pieces of startup wood and close the door right away.

  8. Once a nice coal bed is established and there are still good sized flames, the main larger logs can be loaded into the firebox. Rake the coals to create a uniform charcoal bed. Load 5 pieces of 17″ long cord wood front to back,North/South orientation.

  9. Once strong flames are established close the door.

  10. After 20 minutes the fan can be set on high setting.

  11. After 30 minutes the damper can be adjusted to low or medium setting and the fan switched to the low setting.

  12. For those units installed at higher elevations or into sub-standard masonry fireplaces, drafting problems may occur. Consult an experienced dealer or mason on methods of increasing your draft.

  13. Some cracking and popping noises may be experienced during the heating up process. These noises will be minimal when your unit reaches temperature.

  14. Before opening your door to reload, open the air control fully for approximately 10 to 15 seconds until the fire has been re-established. This will minimize any smoking (spilling) back into the room. After loading wood and front door closed, close the air control to your desired setting only once the fire has been reestablished.

  15. All fuel burning appliances consume oxygen during operation. It is important that you supply a source of fresh air to your unit while burning. A slightly opened window is sufficient for the purpose. If you also have a fireplace in your home, a downdraft may be created by your Regency Stove causing a draft down your chimney. If this occurs, slightly open a window near your unit.
    WARNING: If the body of your unit, or any part of the chimney connector starts to glow, you are over firing. Stop loading fuel immediately and close the draft control until the glow has completely subsided.

  16. If you have been burning your stove on a low draft, use caution when opening the door. After opening the damper, open the door a crack, and allow the fire to adjust before fully opening the door.

  17. The controls of your unit or the air supply passages should not be altered to increase firing for any reason.

  18. If you burn the unit too slowly or at too low a setting your unit will not be operating as efficiently as it can. An easy rule of thumb says that if your glass is clean, then your flue is clean and your exhaust is clean. Burn the stove hot enough to keep your glass clean, you won’t need to clean your flue as often.

How to Light & Maintain a Wood Stove Firehttp://www.youtube.com/watch?v =Vs_pLbJ-JGE&feature=youtu.be

Fan Operation

Automatic
To operate the fan – ensure switch is in AUTO mode.
This will allow the fan to turn on as the stove has come up to operating temperature. It will also shut the fan system off after the fire has gone out and the unit cooled to below a useful heat output range.
Operate the fan in the low speed position when burning in the LOW-MED LOW heat output ranges and operate in the high setting for MED-HIGH to HIGH heat outputs.
Route power cord to either left or right and plug into suitable 3 prong grounded plug.

Ash Disposal
During constant use, ashes should be removed every few days.
Ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.

Safety Precautions

  1. Do not allow ashes to build up to the loading doors! Only remove ashes when the fire has died down. Even then, expect to find a few hot embers.
  2. Please take care to prevent the build-up of ash around the start-up air housing located inside the stove box, under the loading door lip.

Safety Guidelines and Warnings

CAUTION: Do not use chemicals as fluids to start fire.

  1. CAUTION: Never use gasoline, gasoline type lantern fuels, kerosene, charcoal lighter fuel, or similar liquids to start or ‘freshen up’ a fire in your heater. Keep all such liquids well away from the heater while it is in use.
  2. Keep the door closed during operation and maintain all seals in good condition.
  3. Do not burn any quantities of paper, garbage, and never burn flammable fluids such as gasoline, naptha or engine oil in your stove.
  4. If you have smoke detectors, prevent smoke spillage as this may set off a false alarm.
  5. Do not overfire heater. If the chimney connector, flue baffle or the stove top begin to glow, you are over firing. Stop adding fuel and close the draft control. Over firing can cause extensive damage to your stove including warping and premature steel corrosion. Over firing will void your warranty.
  6. Do not permit creosote or soot build-up in the chimney system. Check and clean chimney at regular intervals. Failure to do so can result in a serious chimney fire.
  7. Your Regency stove can be very hot. You may be seriously burned if you touch the stove while it is operating, keep children, clothing and furniture away. Warn children of the burn hazard.
  8. The stove consumes air while operating, provide adequate ventilation with an air duct or open a window while the stove is in use.
  9. Do not connect this unit to a chimney flue serving another appliance.
  10. Do not use grates or andirons or other methods for supporting fuel. Burn directly on the bricks. 11. Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fire.
  11. Do not connect your unit to any air distribution duct.
  12. This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods.
  13. In the event of component failure, replace parts with only Regency listed parts.
  14. Warning: do not abuse glass door such as striking or slamming shut.
  15. Do not store any fuel closer than 2 feet from your unit. Do not place wood, paper, furniture, drapes or other combustibles near the appliance.
  16. CAUTION: Do not operate with broken glazing.

CAUTION: HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.

Maintenance

It is very important to carefully maintain your fireplace stove, including burning seasoned wood and maintaining a clean stove and chimney system.
Have the chimney cleaned before the burning season and as necessary during the season, as creosote deposits may build up rapidly. Moving parts of your stove require no lubrication.
Creosote When wood is burned slowly, it produces tar and other organic vapours combine with moisture to form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote can result in an extremely hot fire.
The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if creosote build up has occurred. If creosote has accumulated it should be removed to reduce the risk of chimney fire.

CAUTION: Things to remember in case of a chimney fire:

  1. Close all draft and damper controls.
  2. CALL THE FIRE DEPARTMENT.

Ways to Prevent and Keep Unit Free of Creosote

  1. Burn stove with the draft control wide open for about 10-15 minutes every morning during burning season.
  2. Burn stove with draft control wide open for about 10 – 15 minutes every time you apply fresh wood. This allows the wood to achieve the charcoal stage faster and burns up any unburned gas vapours which might otherwise be deposited within the system.
  3. Only burn seasoned wood! Avoid burning kiln dried, wet or green wood. Seasoned wood has been dried at least one year.
  4. A small hot fire is preferable to a large smouldering one that can deposit creosote within the system.
  5. The chimney and chimney connector should be inspected at least once every two months during the heating season to determine is a creosote buildup has occurred.
  6. Have chimney system and unit cleaned by competent chimney sweeps twice a year during the first year of use and at least once a year thereafter or when a significant layer of creosote has accumulated (3 mm/1/8″ or more) it should be removed to reduce the risk of a chimney fire.

Door Gasket
If the door gasket requires replacement, use a 7/8″ gasket rope (Part

846-570). A proper high temperature gasket adhesive is required. See your

Regency Dealer.
The door catch may require adjustment as the door gasket compresses after a few fires. The door latch compression may require adjustment to renew seal.
Removal of a shim, (see section in this manual), will allow the latch to be moved closer to the door frame, causing a tighter seal.

Glass Maintenance
Your Regency stove is supplied with 5mm Neoceram ceramic glass (Part

940-370/P) that will withstand the highest heat that your unit will produce.

In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only, and follow our step-by-step instructions for replacement (refer to Glass Replacement section).
Allow the stove to cool down before cleaning the glass. Cleaning the glass will prevent build up of carbon and allow full view of the fire.
WARNING: Do not clean the glass when it is hot.
WARNING: Do not use abrasive cleaners, a damp cloth and glass cleaner is effective.

Wood Storage
Store wood under cover, such as in a shed, or covered with a tarp, plastic, tar paper, sheets of scrap plywood, etc., as uncovered wood can absorb water from rain or snow, delaying the seasoning process.

DO NOT BURN:

  • Treated wood
  • Coal
  • Garbage
  • Cardboard
  • Solvents
  • Colored Paper
  • Trash
  • Salt drift wood
  • Cut lumber, plywood, mill ends.

Burning treated wood, garbage, solvents, colored paper or trash may result in release of toxic fumes. Burning coal, cardboard, or loose paper can produce soot, or large flakes of char or fly ash, causing smoke spillage into the room.

CAUTION: DO NOT BURN GARBAGE OR FLAMMABLE LIQUIDS SUCH AS GASOLINE, NAPTHA OR ENGINE OIL. SOME FUELS COULD GENERATE CARBON MONOXIDE AND ARE VERY DANGEROUS.
CAUTION: DO NOT CONNECT TO, OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCT WORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.

Cleaning & Maintaining Your Wood Stovehttp://www.youtube.com/watch?v=Urff8YTv6Ok&feature=youtu.be

Door Gasket
If the door gasket requires replacement, 7/8″ diameter material must be used. A proper high temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local Hampton dealer.

Glass Cleaning
Only clean your glass window when it is cool. Your local retailer can supply you with special glass cleaner if plain water and a soft cloth does not remove all deposits.

Door Removal
When handling enamel parts, please handle with care as they can be damaged.

  1. Remove the Top Faceplate by lifting straight up from the sides.
  2. Lift off Mantel Top.
  3. Open the Door and lift up off its hinges.

Please be careful when removing the Door and not to drop onto the Ashlip, it may chip.

REGENCY HI2450 Wood Fireplace Insert - Ashlip

DOOR INSTALLATION NOTE
After re-installing the door, carefully swing open and check the clearance to the Right Hand Cast Side. If tight or rubbing, loosen the 7/16 nuts and adjust the clearance and then re-tighten.

Glass Replacement

  1. Open door.
  2. To replace the glass remove the 8 screws highlighted in the diagram below.
  3. Lift off the 4 glass retainers and carefully remove glass.
  4. Place new glass in the door, make sure that the glass gasketing will properly seal your unit.
  5. Position the glass retainer back on. Ensure that it rests on the gasket and not the glass.
  6. Secure glass retainer using the 8 screws. Do not wrench down on the glass as this may cause the glass to break.
    Avoid impact on glass doors such as striking or slamming shut.

Handle Replacement

  1. Remove handle by unscrewing it from the latch.
  2. Fit new door handle over latch and screw it in to place.

REGENCY HI2450 Wood Fireplace Insert - Ashlip 2

Latch Adjustment
The door latch may require adjustment as the door gasket material compresses after a few fires. Removal of spacers will allow the latch to be moved closer to the door frame, causing a tighter seal.

  1. Remove the Latch Assembly from the unit by undoing the outer 2 bolts.
    REGENCY HI2450 Wood Fireplace Insert - Adjustment

  2. Remove the Latch from the Mounting Bracket by undoing the inner 2 bolts.
    REGENCY HI2450 Wood Fireplace Insert - Adjustment 1

  3. Remove necessary amount of spacers sitting on the Mounting Bracket.
    Ensure an equal amount of spacers are removed from both top and bottom.
    REGENCY HI2450 Wood Fireplace Insert - Adjustment 2

  4. Re-secure Latch to Mounting Bracket using 2 bolts.
    REGENCY HI2450 Wood Fireplace Insert - Adjustment 3

  5. Re-secure the Latch Assembly to the unit using 2 bolts.

Annual Maintenance

Completely clean out entire unit| Annually
Inspect air tube and bricks| Replace any damaged parts.
Adjust door catch assembly| If unable to obtain a tight seal on the door – replace door gasket seal. Readjust door catch after new gasket installed.
Inspect condition and seal of: Glass Gasket Door Gasket| Perform paper test – replace gasket if required
Paper Test| Test the seal on the loading door with a paper bill.
Place a paper bill in the gasket area of the door on a cold stove.
Close the door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch, if that doesn’t solve the problem replace the door gasket.
Check and lubricate door hinge + latch| Use only high temperature anti seize lube. (ie. never seize)
Check glass for cracks| Replace if required.
Clean blower motor| Disconnect power supply. Remove and clean blower. DO NOT LUBRICATE
Inspect and clean chimney| Annual professional chimney cleaning recommended.

NOTE:
Chimney Cleaning
When cleaning the chimney system the air tubes, baffles should be removed for ease of cleaning. See manual for details on removal.
We highly recommend that the chimney cleaning be done by a professional as they will have the necessary tools such as a proper sized brush and special vacuum cleaner designed to deal with fine particles.

IMPORTANT:
Before attempting to loosen or remove any screw, bolt from the interior of a wood stove, insert or factory built fireplace that has had a fire burned in it, we highly recommend to liberally spray the screw/bolt with a good-quality penetrating oil, one that does not have flammable properties contained within the penetrating oil being used. Allow it to set, then tap or vibrate the screw or bolt to help loosen it before attempting to remove it. For best results, follow the instructions that are provided with the penetrating oil.

Vertical Stainless Deflector Replacement

REGENCY HI2450 Wood Fireplace Insert - Replacement

  1. Remove 2 front secondary air tubes / vermiculite baffles as per page 24.
  2. Loosen the two 7/16” bolts + nuts to remove / replace vertical baffle.
  3. Repeat steps to install new vertical deflector.

NOTE: ENSURE BAFFLE IS PUSHED UP AS FAR AS POSSIBLE. TIGHT TO TOP OF FIREBOX.

parts list

Main Assembly

| Part #| Description
---|---|---
1)| 942-681 846-686| Right Side Cast 8 mm Soft Fibre Black Gasket
Tape (8′) (936-238)
2)| 300-021| Flange Adaptor
3)| 942-691
| Ashlip
4)| 300-006| Fan Clip
6)| 942-671 846-686| Left Side Cast 8 mm Soft Fibre Black Gasket
Tape (8′) (936-238)
8)| 942-661
| Mantel Top
15)| 300-911| Fan Assembly
20)| 300-571
| Door Assembly
21)| 948-179| Wooden Handle Black
22)| 300-551| Door Latch
23)| 940-370/P846-570| Door Glass
Door Gasket Kit
24)| 846-686| Glass Retainer 8 mm Soft Fibre Black Gasket
Tape (8′) (936-238)
36)| 033-953| Air Tube 3/4″ (Qty:4)
37)| 020-957| Baffle (2/set)
38)|  181-019| Smoke Deflector
40)| 910-157/P|  Fan Motor Only
41)|  021-022| Firebox Floor Gasket
42)| 181-632/P| Flue Adaptor

Not Shown in the drawing:

300-981* Cast Grill
181-039 Wood Damper Handle
910-142 Fan Thermodisc
910-138 2 Way Switch
910-140 3 Way Switch
948-220 Hampton Logo Plate
910-678 120 Volt Power Cord
300-513 Upper Door Hinge Assembly
948-155 Bottom Door Hinge Pin
181-045/P Vertical Stainless Deflector
  • Last digit of part number represents color:
    1 = Metallic Black, 5 = Timberline Brown,

REGENCY HI2450 Wood Fireplace Insert - Replacement 1

Standard Cast Faceplate

  Part # Description
300-921 Cast Faceplate – Metallic Black
300-925 Cast Faceplate – Timberline Brown
  1. *| Top Faceplate
    Left Side Faceplate
    Right Side Faceplate
  • Not available as a replacement part.

REGENCY HI2450 Wood Fireplace Insert - Replacement 2

Oversize Cast Faceplate

Part # Description
300-971 Oversize Cast Faceplate – Metallic Black
300-975 Cast Faceplate – Timberline Brown
  1. 300-060
  2. 300-061| Top Faceplate
    Left Side Faceplate
    Right Side Faceplate
    Mounting Plate LH
    Mounting Plate RH

Not Shown in the Drawing
300-005 Top Retainer

  • Not available as a replacement part.

REGENCY HI2450 Wood Fireplace Insert - Replacement 3

Brick Panels – HI2450

Part # Description
180-960 Firebrick – Complete Set
  1. 902-111
  2. *| Brick Regular Full Size: 1-1/4″ x 4-1/2″ x 9″
    Brick Partial: 1-1/4 x 4-1/2″ x 2″
    Brick Partial: 1-1/4″ x 2″ x 9″

REGENCY HI2450 Wood Fireplace Insert - Replacement 4

warranty

Limited Lifetime Warranty
FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U.S., Inc. (for U.S. customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
Some conditions apply (see below).
The policy is not transferable, amendable, or negotiable under any circumstances.

Wood Products| Component Coverage| Labor
Coverage
---|---|---
Components Covered| Limited
Lifetime| 5
years| 2
years| 1
year| Warranty| (Years)
Welded Firebox Steel| ✓| | | | | 5
All Stainless Steel Components, Smoke Deflectors, Heat Shields etc.| ✓| | | | | 3
Air Tubes| ✓| | | | | 3
Ai rmate| ✓| | | | | 3
Door handle and latch assembly, all hardware| ✓| | | | | 3
Glass Thermal Breakage Only| ✓| | | | | 3
Steel Faceplates, Accessory Housings| ✓| | | | | 3
All Plating| ✓| | | | | 3
Ash Drawer, Heatshields, Pedestal| ✓| | | | |
All Baffles, Steel, Ceramic, Vermiculite C-Baffles| ✓| | | | |
All castings, firebox, surrounds, doors, panels etc.| | ✓| | | | 3
All Electrical, Blower, wiring, switches etc.| | | ✓| | | 2
Glass – Crazing| | | | ✓| | 1
Catalyst Combustor| | | | | *10
Years
Prorated|
Venting/Chimney| | | | ✓| | 1
Screens| | | | ✓| | 1

*See specific warranty details in regards to the catalyst combustor in unit manual.

Conditions:
Warranty protects against defect in manufacture or FPI factory assembled components only, unless herein specified otherwise.
Any part(s) found to be defective during the warranty period as outlined above will be repaired or replaced at FPI’s option through an accredited distributor, dealer or pre-approved and assigned agent provided that the defective part is returned to the distributor, dealer or agent for inspection if requested by FPI. Alternatively, FPI may at its own discretion fully discharge all of its obligations under the warranty by refunding the verified purchase price of the product to the original purchaser. The purchase price must be confirmed by the original Bill of Sale.
The authorized selling dealer, or an alternative authorized FPI dealer if pre- approved by FPI, is responsible for all in-field diagnosis and service work related to all warranty claims. FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty.
All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof of purchase by you). All claims must be complete and provide full details as requested by FPI to receive consideration for evaluation.
Incomplete claims may be rejected.
Replacement units are limited to one per warranty term. Airtube and baffle replacements are limited to one replacement per term.
Unit must be installed according to all manufacturers’ instructions as per the manual.
All Local and National required codes must be met.
The installer is responsible to ensure the unit is operating as designed at the time of installation.
The original purchaser is responsible for annual maintenance of the unit, as outlined in the owner’s manual. As outlined below, the warranty may be voided due to problems caused by lack of maintenance.
Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Exclusions:
This Limited Lifetime Warranty does not extend to rust or corrosion of any kind due to: a lack of maintenance or improper venting, lack of combustion air provision, or exposure to corrosive chemicals (i.e. chlorine, salt, air, etc.).

This Limited Lifetime Warranty also does not extend to: paint, firebricks (rear, sides, or bottom), door gasketing, glass gasketing (or any other additional factory fitted gasketing), vermiculite floor bricks, andiron assemblies, and flue damper rods.
Malfunction, damage or performance based issues as a result of environmental conditions, location, chemical damages, downdrafts, installation error, installation by an unqualified installer, incorrect chimney components (including but not limited to cap size or type), operator error, abuse, misuse, use of improper fuels (such as unseasoned cordwood, mill-ends,
construction lumber or debris, off-cuts, treated or painted lumber, metal or foil, plastics, garbage, solvents, cardboard, coal or coal products, oil based products, waxed cartons, compressed pre-manufactured logs, kiln dried wood), lack of regular maintenance and upkeep, acts of God, weather related problems from hurricanes, tornados, earthquakes, floods, lightning strikes/bolts or acts of terrorism or war, which result in malfunction of the appliance are not covered under the terms of this Limited Lifetime Warranty.
FPI has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications or upgrades will not be performed on existing appliances).
This warranty does not cover dealer travel costs for diagnostic or service work. All labor rates paid to authorized dealers are subsidized, pre- determined rates. Dealers may charge homeowner for travel and additional time beyond their subsidy.
Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty. This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within three (3) months of installation/purchase.
Units which show evidence of being operated while damaged, or with problems known to the purchaser and causing further damages will void this warranty.
Units where the serial no. has been altered, deleted, removed or made illegible will void this warranty.
Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this warranty.
FPI is not liable for the removal or replacement of facings or finishing in order to repair or replace any appliance in the field. Freight damages for products or parts are not covered under the terms of the warranty.
Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty.

Limitations of Liability:
The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL DAMAGES OR DAMAGES TO PROPERTY. TO THE EXTENT PERMITTED BY APPLICABLE LAW, FPI MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED, THEN SUCH WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some U.S. states do not allow limitations on how long an implied warranty lasts, or allow exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
Customers located outside the U.S. should consult their local, provincial or national legal codes for additional terms which may be applicable to this warranty.

How to Obtain Warranty Service:
Customers should contact the authorized selling dealer to obtain all warranty and service. In the event the authorized selling dealer is unable to provide warranty / service, please contact FPI by mail at the address listed on the next page. Please include a brief description of the problem and your address, email and telephone contact information. A representative will contact you to make arrangements for an inspection and/or warranty service, by an alternative dealer.

Product Registration and Customer Support:
Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care /Warranty-Registration.aspx within ninety (90) days of purchase.

Product Registration and Customer Support:
Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
For purchases made in CANADA or the UNITED STATES: http://www.regency- fire.com/Customer-Care/Warranty-Registration.aspx
For purchases made in AUSTRALIA: http://www.regency-fire.com.au/Customer-Care /Warranty-Registration.aspx
You may also complete the warranty registration form below to register your Regency Fireplace Product and mail and/or fax it back to us, and we will register the warranty for you. It is important you provide us with all the information below in order for us to serve you better.

Warranty Registration Form (or Register online immediately at the above Web Site):

Warranty Details

Serial Number (required):|
Purchase Date (required) (mm/dd/yyyy):|
Product Details
Product Model (required):|
Dealer Details
Dealer Name (required):|
Dealer Address:|
Dealer Phone #:|
Installer:|
Date Installed (mm/dd/yyyy):|
Your Contact Details  (required)
Name:|
Address:|
Phone:|
Email:|
For purchases made in CANADA:
FPI Fireplace Products
International Ltd.
6988 Venture St.
Delta, British Columbia
Canada, V4G 1H4
Phone: 604-946-5155
Fax: 1-866-393-2806| For purchases made in the UNITED STATES:
Fireplace Products US, Inc.
PO Box 2189 PMB 125
Blaine, WA
United States, 98231
Phone: 604-946-5155
Fax: 1-866-393-2806| For purchases made in AUSTRALIA:
Fireplace Products Australia Pty Ltd
99 Colemans Road
Dandenong South, Vic. 3175
Australia
Phone: +61 3 9799 7277
Fax: +61 3 9799 7822
---|---|---

For fireplace care and tips and answers to most common questions please visit our Customer Care section on our Web Site.
Please feel free to contact your selling dealer if you have any questions about your Regency product.

Installer: Please complete the following information
Dealer Name & Address: _____


Installer: ____
Phone #: ____
Date Installed: ____
Serial #: _____

Regency and Classic are trademarks of FPI Fireplace Products International Ltd.
© Copyright 2022, FPI Fireplace Products International Ltd. All rights reserved.

Printed in Canada

Documents / Resources

| REGENCY HI2450 Wood Fireplace Insert [pdf] Instruction Manual
HI2450 Wood Fireplace Insert, HI2450, Wood Fireplace Insert, Fireplace Insert, Insert
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals