GENERAL INFORMATION

  1. A qualified electrician, in accordance with IEE wiring regulations should carry out connection to mains wiring.
  2. Ensure that the rated voltage and frequency requirements are compatible with the available mains supply.
  3. Do not carry out high voltage insulation test, i.e. 500/1000v this may damage internal components.
  4. The light source contained in the luminaire shall only be replaced by the manufacturer or a designated service agent or a suitably qualified person.
  5. Batteries used in emergency version of this luminaire range are replaceable by a qualified electrician.
  6. If used, ensure that the DALI control cable has an equivalent insulation rating as the LV supply cable. The DALI control cable must be double insulated.

SPECIFICATION

Lumen outputs & wattages (TBC) 400lm (4W), 750lm (6W), 1500lm (12W)
Finish RAL9005 Black textured, RAL9006 Silver textured
Materials Aluminum (Top cover, body), Steel (Base plate, root mount,

reflector, gear trays, screws & fixings), Polycarbonate (Diffuser, plastic pins, glands), Acrylic (Diffuser), ABS (IP Box)
Weight (TBC)| 0.5m Root (7.5kg), 1.0m Root (9.3kg), 0.5m Flange (5.5kg), 1.0m Flange (7.3kg)
Supply| 220-240v ac50-60Hz
Connection (5 core plug)| Cable section: 5 core-0.5mm² to 1.5mm² (6mm strip length)
Connection (6 core plug)| Cable section: 6 core-0.2mm² to 2.5mm² (8mm strip length) TORX6-KEY REQUIRED FOR PLUG. (TORX T6 SCREW HEAD)
Ingress/Impact protection| IP66, IK10
Temp Range| -5°c to +35°c

Whitecroft Lighting Limited

  • Burlington Street, Ashton-Under-Lyne, Lancashire OL7 0AX Telephone: +44 (0)161 330 6811
  • Registered No: 3848973 England
  • Technical Support
  • Telephone: 0161 331 5700
  • Email: technical@whitecroftlight.com

KOLO BOLLARD

REMOVE ALL PACKAGING AND ENSURE THERE IS NO DAMAGE TO THE PRODUCT. REPLACE PACKAGING WHILST INSTALLING TO PREVENT CAUSING DAMAGE.

IMPORTANT ORIENTATION INFORMATION.

IT IS IMPORTANT THAT THE ROOT/FLANGE MOUNT ARE CORRECTLY POSITIONED WHEN INSTALLED. POSITION 1 OF THE 3 FIXING POINTS TO WHERE THE FRONT OF THE PRODUCT SHOULD BE. SEE DIAGRAM TO THE RIGHT.

Whitecroft Lighting Limited

Whitecroft-lighting-BLY114KARB-Kolo-Bollard-Robust-and-Weatherproof-
Versatile-LED-Bollard-03

Whitecroft-lighting-BLY114KARB-Kolo-Bollard-Robust-and-Weatherproof-
Versatile-LED-Bollard-04

  • Dig a hole at least 300 X 300 X 450mm deep. A gravel layer (J) at the bottom is recommended for better drainage.
  • Remove root mount (H) from body (E), via 3 x M6 screws (F).
  • Attach provided nut and bolt (I) to root mount (H). (Stored inside body (E) )
  • Feed armored cable (K) through cut out in root mount (H). Ensure there is enough cable for wiring to the bollard. (Approx. 100mm above ground level.)
  • Support the root mount so a 5mm gap can be achieved from ground level as shown. This will ensure the bollard will connect properly when the concrete has set.
  • Fill the hole with concrete. DO NOT USE QUICK SETTING CONCRETE. Make sure the root mount (H) tube fills with concrete.
  • Check the bollard can be attached to the root mount, before allowing the concrete to set.

FLANGE MOUNT INSTALLATION.

  • Dig a hole so that the bollard is adequately supported. (Suggested 300 X 300 X 400mm minimum.)
  • Ensure there is enough armored cable (K) for wiring to the bollard. (Approx. 100mm above ground level.)
  • Fill the hole with concrete. DO NOT USE QUICK SETTING CONCRETE.
  • Fit J-bolts into concrete, use flange mount plate (G) as a guide.(Recommended size M12 x 150mm)
  • Remove flange mount plate (G) from the body (E), via 3 x M6 screws (D)
  • Feed armored cable through central hole on flange mount plate (G).
  • Flange mount plate (G) should be attached using ‘J-bolts’ (L), Raw bolts can also be used. Recommended size is M12 x 150mm. (Not Supplied)

WIRING INFORMATION

  • Bollard supplied with male and female IP plug. Male end is wired to the product. Female end is to be wired to the armored cable.
    • Connection (5 core plug) Cable section: 5 core-0.5mm² to 1.5mm² (6mm strip length)
    • Terminals (5 core plug) 1,2 (DALI) 3 (LIVE) 4 (EARTH) 5 (NEUTRAL)
    • Connection (6 core plug) Cable section: 6 core-0.2mm² to 2.5mm² (8mm strip length)
    • Terminals (6 core plug) 1,2 (DALI) L (LIVE) N (NEUTRAL) Ls (SWITCHED LIVE)

Whitecroft-lighting-BLY114KARB-Kolo-Bollard-Robust-and-Weatherproof-
Versatile-LED-Bollard-06 Whitecroft-lighting-BLY114KARB-Kolo-Bollard-
Robust-and-Weatherproof-Versatile-LED-Bollard-07

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Whitecroft lighting User Manuals

Related Manuals