Dear customer, thank you for purchasing one of our Uniteck products. Please read all the instructions carefully and thoroughly before using the product.

Unifix brackets have been specially designed to fix your Unisun photovoltaic panels or equivalent (see compatible panels part):

  • Unifix 100 for your Unisun 80.12M /100.12M /100.24M/110.12BC panels.

UNIFIX 100

Easy to install, they attach either:

  • on a rigid horizontal or vertical surface (eg wall, concrete floor, wooden frame).
  • on a round mast with a diameter of 40 to 60 mm (flange included)
  • on a signaling posts using flanges with M8 screws

With their galvanized steel structure and corrosion-resistant stainless-steel screws, they are perfectly suited for outdoor use.

Equipped with a multi-position tilting system, Unifix brackets allow for an optimization of your panel’s performance depending on the chosen orientation.

  1. Adjustable By 10 °

Electrical performance depending on tilt and panel orientation

| | 30°| 60°| 90°
---|---|---|---|---
East| 93%| 90%| 78%| 55%
South east| 93%| 96%| 88%| 66%
South| 93%| 100%| 91%| 68%
South west| 93%| 96%| 88%| 66%
West| 93%| 90%| 78%| 55%

PANEL COMPATIBILITY

With the design based on the use of Oblong drilling, Unifix can be used with different kind of panels on the market.
Unifix 20 is ment to fix 1 panel only, with the spacings and dimensions of panels as indicated below.

Oblong fastening system

Centre distance and panel dimensions

| Unifix 100
---|---
Dim Support| L| 1070
H| 550
Number of panels| x1| ●
x2|
x3|
Spacers for fastening of each panel (in mm)| L (e)| 340 > 885
H (e)| 180 > 510
Panel Dimension Max| L (p)hh| No max
H (p)| 550
Total weight Of panels (In Kg)| 12

RECOMMENDATIONS

Mount Unifix brackets only on surfaces with sufficient bearing capacity. Consider the additional load with the panel:

Support

| Panel
---|---
Unifix 100 = 4,4 kg|

Unisun 80.12M/ 100.12M / 100.24M / 110.12BC =6,3kg / 7,5kg / 7,5kg / 7kg

Fastening: to prevent large quantities of snow from accumulating behind the sensor, install appropriate barrier grids.

The position of the solar panel influences your electrical production. Choose the most optimal inclination and orientation to suit your environment. Avoid shaded areas or objects that are a source of shadow (eg tree)

Before attaching and connecting, please observe:

  • the maximum distances between each element shown below.
  • connecting order
SAFETY INSTRUCTIONS
  • Take the appropriate mesures to prevent accidents during your mounting steps.
  • If the bracket and the mounting tools are exposed to sunlight for a long period, there is a risk of getting burnt. Make sure to protect yourself accordingly.
  • When finished, check and ensure that all of your brackets and panels are fixed properly.
UNIFIX 100 – PREPARATION
LIST OF PIECES

| | |
---|---|---|---
M8x100 X4| M8x20 x20| D8 x24| M8 x24
| | | |
---|---|---|---|---
n°15 x2| n°16 x2| n°34 x1| n°14 x2| n°13 x2

Recommended tightening torque

Vis Couple
M5 5,10 Nm
M 6 8,80 Nm
M 8 21,50 Nm
M 10 44,00 Nm

Nb. Average friction coefficient µ= 0.20 / Tightening at 50% of the elastic limit

UNIFIX 100 – PREPARATION BEFORE MOUNTING
  • Attach the 2 n°14 pieces to the frame of your Unisun solar panel. Pre-tighten the nuts. The final tightening will be done at the end of the assembly.

| | |
---|---|---|---
M8x20 x4| D8 x4| M8 x4| n°14 x2

UNIFIX 100 – WALL MOUNTING / FLOOR / ROOF
  • Attach parts n° 15 and n°16 to part n°34. Place n°15 and 16 according to the size of your solar panel. Pre-tighten the nuts. The final tightening will be done at the end of the assembly.

| | | | |
---|---|---|---|---|---
M8x 20 x8| D8 x8| M8 x8| n°15 x2| n°16 x2| n°34 x1

  • Fix your bracket with 8 screws adapted to the supporting surface (screws and dowels not supplied).

Unifix is equipped with a multi-position tilt system. (10 positions). Set the desired tilt depending on the desired orientation.

  1. Adjustable by 10°

| | 30°| 60°| 90°
---|---|---|---|---
East| 93%| 90%| 78%| 55%
South east| 93%| 96%| 88%| 66%
South| 93%| 100%| 91%| 68%
South west| 93%| 96%| 88%| 66%
West| 93%| 90%| 78%| 55%

  • Attach your panel to the tilt system

| |
---|---|---
M8x20 X8| D8 X8| M8 X8

  • Now tighten the 8 nuts that were previously pre-screwed.
UNIFIX 100 – FIXING ON ROUND MAST (DIAM 40 TO 60 MM)
  • Attach the bracket to the mast with 2 flanges and associated M8 screws (for fixing to the signal mast, use the flanges corresponding to the mast used, flanges not included

  • Unifix is equipped with a multi-position tilt system. (10 positions). Set the desired tilt depending on the desired orientation.

  1. Adjustable by 10°

Electrical performance depending on tilt and panel orientation

| | 30°| 60°| 90°
---|---|---|---|---
East| 93%| 90%| 78%| 55%
South east| 93%| 96%| 88%| 66%
South| 93%| 100%| 91%| 68%
South west| 93%| 96%| 88%| 66%
West| 93%| 90%| 78%| 55%

  • Attach your panel to the tilt system

| |
---|---|---
M8x20 X8| D8 X8| M8 X8

  • Now tighten the 8 nuts that were previously pre-screwed
WARRANTY

The warranty covers any defect, manufacturing flaws for 1 year from the date of its purchase (Pieces and workforce).

Warranty does not cover:
– normal wear of parts
– falty mounting of bracket

In case of failure, return the product to your distributor by attaching:
– the dated proof of purchase (receipt, bill…)
– explanatory note of the failure

Caution: Our after-sales service does not accept carriage forward/ collected returns.

After the warranty, our after-sales service ensures repairs after acceptance of a quotation.
After-sales service contact :
Uniteck- 1 Avenue de Rome
Zae Via Europa – bâtiment Cassis
34350 Vendres -France
E-mail : sav@uniteck.fr
Fax : +33 (0)4 88 04 72 20


www.uniteck.fr

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals