PANASONIC F-60FEN Ceiling Fans Instruction Manual
- June 15, 2024
- Panasonic
Table of Contents
PANASONIC F-60FEN Ceiling Fans Instruction Manual
Operating and Installation Instructions
Ceiling Fan
Thank you for purchasing this Panasonic product.
Before operating this product, please read the instructions carefully, and
save this manual for future use.
Safety precautions
To avoid the possibility of causing injury to users or damage to properties, please follow all the explanations written below.
Maintenance
-
Check the Ceiling Fan condition annually. If a problem occurs, stop using the Ceiling Fan. Then refer to a service, sales or maintenance shop.
Check point:
Loosened screws, safety wire condition, motor shaft damage, etc. -
Ensure Safety Switch in good condition.
If a problem occurs, stop using the Ceiling Fan. Then refer to service or authorized dealer. -
Keep the Ceiling Fan clean. Wipe away dirt with a clean soft cloth, ordinary soap and water. Wipe it again to dry it. Do not use solvents (gasoline, petroleum, thinner, benzine, alcohol, cleaning powder, alkaline detergent) or any other chemicals.
• Do not bend the Blade while cleaning. -
Do not paint the Blades. If damaged, order a new set of Blades (5 pieces) from a service shop or a sales shop.
-
When referring to a service, sales or maintenance shop, show these instructions to them so that maintenance will be done correctly.
-
If the product is broken or damaged, remove it from the ceiling and replace with new. This is to avoid the Ceiling Fan drops.
-
The Ceiling Fan suspension system should be examined at least once every two years.
Name of parts
Parts piece(s)
A Upper Canopy ………………………… 2
B Lower Canopy ………………………… 2
C Blade Assembly ……………………… 5
D Motor Unit ……………………………… 1
E Batteries AAA / R03 / LR03 ……… 2
F Remote Control ……………………… 1
G Remote Control Holder Set …….. 1
H Part Set (10 Screws) ……………….. 1
Attention:
-
Do not place the Ceiling Fan directly on the floor.
Refer to page 10 (Step 1) for the installation method.
Can cause scratches to the product.
Note: -
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
⚠ WARNING
? Do not use modified parts other than original supplied parts.
Can cause injury if the Ceiling Fan drops.
How to install
■ Install the Blades
- Put the Motor Unit D on the round portion (INSTALLATION AREA a ) of the PACK B b as shown to assemble the Blade Assembly C .
- Assemble the Blade Assembly C towards the Safety Hook a .
- Pull the Blade Assembly C in the direction as shown to lock the Blade.
- Tighten the Blades Assembly firmly with the Screws H provided (Taken from the Part Set). Use 2 screws for one Blade Assembly.
For reference, tightening torque is 250-300 Ncm.
Ensure the Blade Assembly screw hole is center with the Diecast Cover t assembly screw hole. Hold the Blade Assembly during installation.
■ Install to ceiling
-
Remove the supplied Bolt b , Nut c , Cotter Pin d and Pulley e .
-
Ensure that the Ceiling Hook (“J” hook c ) or (“U” hook d ) is not loosen.
For reference, the Ceiling Hook (“J” hook c ) or (“U” hook d ) can sustain 20 N. -
Place Pulley e on to the Ceiling Hook c .
-
Tighten the Pulley Set Plate e1 firmly with the Bolt b and Nut c provided.
For reference, tightening torque is 1500-1800 N•cm.
• Cotter Pin d must fix into Bolt b and bent.
⚠ WARNING
ℹ Ensure that the Ceiling Hook can sustain more than 10 times the Ceiling Fan
weight. Safety Wire must be fixed correctly to the Pipe.
Can cause injury if the Ceiling Fan drops.
✅ Check point after installation
Make sure Bolt and Nut are firmly tightened and Cotter Pin is inserted and
bent for safety reason.
Make sure Ceiling Fan is securely fixed on Ceiling Hook and Ceiling Fan not
slanting after installation.
The Safety Wire is looped to the Ceiling Hook and securely fixed to the
Pipe.
■ Wiring instruction
Connect the house’s supply wire f to the terminal h according to the diagram
shown.
• Recommended wire stripping length is 7 ~ 8 mm.
■ Attention:
- It is recommended to user to install OFF/ ON switch on the wall for the Ceiling Fan, replacing existing regulator or new regulator point.
- This product should be installed with a double poles single throw switch (breaker switch) with a minimum of mm contact gap in the fixed installation circuit.
- Should there be a regulator or dimmer switch, disconnect it and reconnect the wiring as above.
- Do not use regulator or dimmer switch for this model.
(It can damage the Ceiling Fan)
• If your Remote Control missing or misplaced, the Ceiling Fan can be switched on pre set speed 5
■ Installing the Canopy
-
Remove the screw (2 pieces) i from Upper Canopy A and keep it for Step 4 – 4.
-
Align and insert the Fixing Rib j of the Lower Canopy B (2 pieces) into the Lower Canopy Fixing slot k . Clip it until it is fully fixed.
-
Make sure Lower Canopy B sit properly on the slot k before fix Upper Canopy A .
-
Align and insert the Fixing Rib I of Upper Canopy A into the Fixing Slot m of Lower Canopy B .
Clip it until it is fully fixed.
Ensure Upper Canopy A (2 pieces) is sit on top of Lower Canopy B . -
Check the gap between the Upper Canopy A and ceiling is approximately 5 mm. Tighten the Upper Canopy A with the screw i which is removed in Step 4 – 1.
Attention:
- Do not assemble the Fixing Rib I of Upper Canopy A in opposite direction.
- Can cause abnormal noise.
■ Install Remote Control Holder
Install the Remote Control Holder Set G to wall. Fix the Remote Control Holder n using provided Screw o (2 pieces) and Wall Plugs p (2 pieces) as shown in figure below.
- Distance between holes q is 53 mm.
- Depth for Wall Plug r is 30 mm.
Attention:
- The Wall Plugs are not needed for wooden wall.
■ Before use
-
Remove the Battery Cover s from Remote Control F .
-
Insert the Batteries (2 pieces AAA / R03 / LR03).
• “+” “-” position should match. -
Close the cover s .
■ Attention:
- Please remove all Batteries before disposing the Remote Control.
- The life of Battery is about one year for a normal usage.
- Replace all Batteries at one time and be careful not to mix Battery type.
■ Attention:
-
If the Ceiling Fan is found to wobble during operation, fix the Blades at different combination of position.
Repeat this step until the Ceiling Fan stop wobbling. -
Make sure Ceiling Fan is securely fixed on Ceiling Hook and Ceiling Fan not slanting after installation to prevent Ceiling Fan wobbling.
-
If Ceiling Fan still wobbles after Step 1 – 4 (page 10), please refer to service or authorized dealer.
■ Remote Control Coverage
-
The figure above shows the best coverage area (W) around 8 m. The ideal ceiling height (H) is 3 to 4 m.
The Remote Control must be pointed to the direction of the Ceiling Fan when in use. -
Avoid the following situations:
• Netting and Glass g can reduce the signal power or reflect the infrared signal from the Remote Control.
• Lighting eff ect generated by Fluorescent Lighting Systems h directly onto the product receiver area can affect the signal transmission.
• Obstacles such as Walls or Glass i between the product receiver and Remote Control can cause signal transmission failure.
Attention:
- The power consumption when the operation is turned off by Remote Control is about 0.5 W.
- It is recommended to switch off wall switch or breaker if Ceiling Fan is not in use for long period for zero power consumption purpose.
■ How to use Remote Control
-
OFF/ON Button
Press to activate or stop the Ceiling Fan.
“ON” – Short beeping sound.
“OFF” – Long beeping sound. -
1/f YURAGI Button
Press to activate 1/f YURAGI mode.
“1/f ” will be shown in LCD screen. -
TIMER Button
Press to select ON TIMER or OFF TIMER.
ON TIMER : To turn ON the Ceiling Fan according to the time and speed setting.
(On Timer LED light at Ceiling Fan will be turned on).
Refer to 5 on page 20.
OFF TIMER : To turn OFF the Ceiling Fan according to the time and speed setting.
Refer to 6 on page 20. -
TIME SETTING Button
Press to select the OFF TIMER and ON
TIMER from 1 hour to 8 hour. -
Transmitter
-
LCD Display Screen
-
SPEED Button
Press SPEED button to increase or decrease fan speed. Minimum fan speed is 1, maximum fan speed is 9. -
SLEEP MODE Button
To stop the Ceiling Fan according to the time setting.
For SLEEP MODE function, refer to 7 on page 20. -
AUTO MODE Button
Press to activate or to stop ECONAVI MODE.
“ECONAVI” will be shown on LCD Display Screen.
■ LCD Display
Figure above shows that LCD Display is in off condition when OFF/ON button on Remote Control Unit is pressed.
■ Speed Display
■ Timer Display
■ 1/f YURAGI (natural breeze)
Add smooth accent to air capacity and comfortable wind more naturally.
To activate 1/f YURAGI function according to speed setting.
- Select a desired speed (speed 1~9).
- Press “1/f YURAGI” button on Remote Control to activate 1/f YURAGI function.
• Press again to deactivate 1/f YURAGI function.
1/f YURAGI speed change pattern
This pattern is an example for 1/f YURAGI setting at speed 4.
Note:
• 1/f YURAGI function does exist for speed 1 but less noticeable compared to
higher speed (speed 4 and above)
■ ON TIMER
The Timer will hourly count down until fan is switched ON.
• During this timer count down, fan will remain OFF until count down is
completed.
- Step 1 : Select a desired speed (speed 1 ~ 9), 1/f YURAGI or AUTO MODE.
- Step 2 : Press “TIMER” button to select ON TIMER (On Timer LED light at Ceiling Fan will be turned on).
- Step 3 : Press “TIME SETTING” button to select desired time frame (1 ~ 8 hours).
■ OFF TIMER
The Timer will hourly count down until fan is switched OFF.
• During this timer count down, speed will remain the same until the Ceiling
Fan is OFF.
- Step 1 : Select a desired speed (speed 1 ~ 9), 1/f YURAGI or AUTO MODE.
- Step 2 : Press “TIMER” button to select OFF TIMER.
- Step 2 : Press “TIME SETTING” button to select desired time frame (1 ~ 8 hours).
■ SLEEP MODE
Ceiling Fan speed and timer will gradually reduce until the Ceiling Fan is
OFF.
Refer SLEEP MODE chart on page 21.
• During this timer count down, speed will go down until the Ceiling Fan is OFF.
- Step 1 : Select a desired speed (speed 2 ~ 9) or 1/f YURAGI.
- Step 2 : Press “TIMER” button to select OFF TIMER. SLEEP MODE will only shown with OFF TIMER turn on.
- Step 3 : Press “TIME SETTING” button to select desired time frame (2 ~ 8 hours).
- Step 4 : Press “SLEEP MODE” button. “SLEEP MODE” will be shown on LCD Display screen. SLEEP MODE is ON.
■ ECONAVI MODE
ECONAVI MODE function is to control suitable air velocity to human.
It will function based on changing of room temperature.
Air velocity will increase when room temperature in high temperature and reduce when room in low temperature.
Note:
- The room temperature varies at different location in a room.
- ECONAVI MODE sensor only detects the room temperature around the sensor position.
- Fan speed adjustment will start after ECONAVI MODE is activated for 10 minutes.
- Afterwards, ECONAVI MODE sensor will undergo temperature detection in every 3 minutes for fan speed adjustment.
-
Select a desired speed (speed 1~9).
• Selected speed will be ECONAVI MODE initial speed. -
Press “AUTO MODE” button on Remote Control to activate ECONAVI MODE function.
ECONAVI LED light at Ceiling Fan will be turned on.
• Press again to deactivate ECONAVI MODE. Fan speed will return to initial speed.
Note:
- Speed cannot be changed during ECONAVI MODE activated.
- SLEEP MODE cannot be activated during the operation of ECONAVI MODE.
Note:
- Controlling of speed change for ECONAVI MODE function is between speed 1 to speed 9.
Example for ECONAVI MODE Function.
- Operating in high room temperature.
- Operating in low room temperature.
■ nanoeTM X Operation
A nanoeTM is a nano-sized ion particle coated with water particles.
- nanoeTM X are nano-sized electrostatic atomized water particles with 10 times the OH radicals of nanoeTM (up to 4.8 trillion radicals are generated per second)
Note:
- nanoeTM X is generated by gathering moisture in the air and the eff ect may change.
- There is a slight “jee” sound when nanoeTM X is in operation.
- The operation mode of nanoeTM X is switched ON automatically regardless of the Ceiling Fan speed setting and will be switched off when the fan is turned off .
■ nanoeTM X ON/OFF Operation
Mode transition
- By pressing and holding “SLEEP MODE”, the mode changes as follows:
Note:
- nanoeTM X ON/OFF condition cannot be changed when the OFF TIMER is activated.
- nanoeTM X is momentary stopped 30 minutes for every 4 hours continuous operation.
Specifications
Voltage (VAC)
Frequency (Hz)
Wattage (W)
Speed 1 / Speed 9
Rotation (RPM)
Speed 1 / Speed 9
Air Velocity (m/min)
Air Delivery (m3 /min)
Attention:
- Do not expose yourself continuously to direct wind from the Ceiling Fan. It can cause discomfort.
Panasonic Corporation
Web Site: http://panasonic.net/
© Panasonic Ecology System Co., Ltd 2023