PROBRITE PHX12-PC-3K-WH Phoenix LED Architectural Wallpak Installation Guide

June 6, 2024
PROBRITE

PHOENIX LED
ARCHITECTURAL
WALLPACK
INSTALLATION,
USAGE, & CARE GUIDE
Model No. PHX12-PC-3K-WH
Mfr. SKU 103-07300002-1

Visit us online anytime or call us to get information on our product range, download detailed spec & photometric files, find product and mounting accessories, view installation tutorials and videos, and learn about our DLC® rebate eligible products.

Safety Information

IMPORTANT
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

PRECAUTIONS

  • Please read and understand this entire manual before attempting to assemble, install, or operate this light fixture.
  • This light fixture requires a 120-Volt AC power source.
  • Some codes require installation by a qualified electrician.
  • This light fixture must be properly grounded.
  • Make sure connections are secure using wire nuts, crimp-on lugs, or other approved connecting devices
  • This light fixture should be installed outdoors to a wall or eave.
  • This product may contain chemicals known to be hazardous. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching the product.

WARNING: Turn the power off at the circuit breaker or fuse. Place tape over the circuit breaker switch and verify power is off at the light fixture.
WARNING: Risk of fire. Keep the lamp heads at least 3 in. (76mm) from combustible materials.
CAUTION: Burn hazard. Allow the light fixture to cool before touching.
NOTICE: Do not connect this fixture to a dimmer switch.
NOTICE: FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user’s authorization to operate this equipment.
INFORMATION: The device is tested and found to comply with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) This device may not cause harmful interference and, (2) this device must accept any interference received, including any interference that may cause undesired operation.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

Pre-Installation

PLANNING INSTALLATION
Before installing the light fixture, ensure that all parts are present. Compare parts with the Hardware Included and Package Contents sections. If any part is missing or damaged,  do not attempt to assemble, install, or operate this light fixture. Estimated installation time: 15 minutes

SPECIFICATIONS

Lumens (Light Output) 900 Lumens
Watts (Power Consumption) 12 Watts LED
Replaces 75 Watt Incandescent Bulbs
Lumens/Watts (Efficacy) 75 lumens per watt
Power Requirements (Input Voltage) 120VAC
Light Color (CCT) 3000 Kelvins (Warm White)
Dimmable Non-Dimming (Do not wire to dimming switch)
Operating Modes **Dusk-to-Dawn:

Automatically turns light fixture ON during night and OFF during day.
Switch-Controlled:
** Flip switch to turn light fixture ON and OFF. Use included opaque light sensor cap on fixture’s light sensor to utilize this mode setting.

TOOLS REQUIRED

Pre-Installation (continued)
HARDWARE KIT

Part Description Quantity
AA #8-32 x 3/4″ philips mounting bracket screw 2
BB Wire nut 3
CC Clear photocell (light sensor) screw-on cap 1
DD Allen key 1

PACKAGE CONTENTS

Part Description Quantity
A Light fixture 1
B Photocell (light sensor) 1
C Mounting plate tightening bolt (pre-installed) 1
D Mounting plate with gasket (pre-installed) 1
E Hanger Wire for hands-free installation (pre-installed) 1
F Opaque photocell (light sensor) screw-on cap 1

Installation

1 For best results

  • Install light 5-10 feet above the ground.
  • Do not mount fixtures close to reflective surfaces such as windows, white walls, white surfaces, and water.
  • When installing two fixtures on one switch, make sure the switch is rated for at least a 1A inductive load.
  • Do NOT wire to a dimming switch.
  • When mounting the fixture, make sure the photocell orientation is at the top.
  • When mounting, make sure the fixture is 7 in. on center away from the eave and 13 inches on center away from the inside corner of the exterior wall (fig 1).

NOTE: Mounting plate (D) mounts to recessed mounted standard junction boxes. Junction box must be at least 1-1/2 inch in depth for proper installation for recessed mount application (fig 2).

2 Shut electric power off

  • At wall switch verify it is in the off position (fig 1).
  • At the main electrical panel turn off the circuit breaker that supplies power to the outlet box you are working on (fig 2).
  • For screw-in type fuses unscrew the fuse that supplies power to the outlet box you are working on (fig 3).

3 Remove the mounting plate
NOTE:
The mounting plate (D) comes pre-assembled on the light fixture (A) for shipping.
NOTE: The mounting plate tightening bolt (C) comes pre-installed on the light fixture.

  • Remove the mounting plate (D) from the back of the fixture by loosening the mounting plate tightening bolt (C) using the allen key (DD).

TIP: Only unscrew the tightening bolt (C) far enough to remove the mounting plate (D). Do not fully remove the tightening bolt (C).

4 Installing the mounting plate

  • Route the junction box wires through the large center hole in the mounting plate (D).
  • Align the holes on the mounting bracket (D) with the holes on your junction box. Use two #8 screws (AA), depending on the size of the holes in your junction box, attach the mounting bracket (D) to your junction box
  • Please make sure , the “TOP” arrow is pointing upwards.

5 Hang fixture to a mounting plate

  • Place the small sphere head of the hanger wire (E) between the back of the small grove located on the bottom of the center hole of the mounting plate (D).
  • Ensure the photocell (B) is facing upwards when light fixture (A) is installed.

TIP: Ensure the light fixture (A) can safely hang onto the mounting plate (D) to allow for use of two hands to make the wiring (fig 2). connections.

6 Making the electrical connections

  • If necessary, strip 3/8″ of insulation from junction box or fixture (A) wires (fig 1).
  • Connect fixture black wire to house black wire, the (+) line, and fixture white wire to house white wire, the (-) common by twisting the exposed wires together and using the wire nuts (BB). Ensure no loose wires.
  • Connect house ground wire to the green fixture ground wire, which is attached to the mounting plate (D), by twisting the exposed wires together and using the wire nuts (BB).

TIP: Hold stripped ends near each other and align any frayed strands (do not twist wires). Push the wires into wire nut (BB) and use your fingers to twist the wire nut clockwise until tight. Check for tightness by pulling wires.

7 Mounting the light fixture

  • Once the fixture is wired, place the light fixture (A) onto the mounting plate (D) so the top sloped grove on the plate rests on the top sloped grow on the back of the fixture.
  • Verify the fixture is flush with the wall and photocell (B) is pointed upward for a wall mount.
  • Tighten the mounting plate tightening bolt (C) back through the hole on the bottom of the fixture (A) until the bolt firmly pushes against the mounting plate (D).

8 Caulking around the light fixture

  • Caulk around the mounting plate (D) and surface with silicone sealant (not included).

NOTICE: Failure to properly caulk around the surface and mounting plate (D) could lead to water damage and is not covered under warranty.
NOTE: When attaching this fixture (A) to an external, surface mount junction box, caulk the inside of the light fixture before attaching to the mounting plate (D).

Operation

1 Selecting Dusk-to-Dawn or Switch-Activated control
OPTION 1: DUSK-TO-DAWN OPERATION
Dusk-to-dawn operation enables the light fixture to automatically turn ON when dark outside and turn OFF when the sun rises, thus saving you energy.

Operation (continued)

  • To enable the dusk-to-dawn operation to remove the black cap cover and ensure the photocell (B) has clear cap cover (CC) on it and is unobstructed.
  • Ensure the switch powering the outlet connected to the light fixture is turned to the ON position and leave it at all times to enable dusk-to-dawn functionality to operate automatically.

(Remove Opaque Cap Cover (CC)and replace with Clear Cap Cover (F) on photocell for Dusk-to-Dawn Operation)
TIP: To test if the light fixture (A) and photocell (B) works properly run power to the fixture and cover the photocell to turn the fixture ON. Shine a light into the photocell to
see if the fixture turns OFF.
NOTE: If photocell (B) is located in an area under the heavy shade the photocell may not detect enough light and may turn the light fixture on.
OPTION 2: SWITCH CONTROLLED
Switch-controlled operation enables the light fixture to turn ON and OFF by flipping a switch that controls the electricity to the outlet powering the fixture. The light fixture will not turn ON and OFF automatically but is manually controlled.

  • To enable switch activated operation leave the black screw-on cap the photocell (already installed on the fixture) and remove the instructions label.

Care and Cleaning

  • Shut off the main power supply before cleaning the product. To prolong the original appearance, clean the light fixture with clear water and a soft, damp cloth only.
  • Do not use abrasive cleaners or cleaners that contain alcohol. Do not apply paints, solvents, or any other chemicals to this light fixture. They could cause premature deterioration of the finish and may void the warranty.
  • Do not spray the light fixture with a hose or power washer.

Troubleshooting

Problem Possible Cause Solution
Light does not turn ON No power to the fixture

Check if a circuit breaker is tripped Confirm wall switch is ON

Verify wiring to fixture is correct (turn power off to fixture beforehand)

Fixture is sensing daylight| Cover photocell. Wait several seconds until fixture turns ON.
Light cycles ON and OFF continuously| Photocell light sensor is sensing reflected light| Relocate light fixture to a location where there is no reflected light. OR place the optional opaque photocell cover over the photocell light sensor and use the wall switch to turn the light ON and OFF.
Light FLICKERS| The light fixture is wired through a dimmer switch.| Do not use a dimmer switch to control the light fixture. Replace the dimmer switch with a standard ON/OFF wall switch.
Light stays ON| Light sensor is in a shaded area| Shine a flashlight into the light sensor for a few minutes. If the light turns OFF, the fixture should be moved to a location with enough light in the daylight hours for the light sensor to work. OR place the optional cover over the photocell light sensor and use the wall switch to turn the light ON and OFF.
Light Sensor is faulty| If the light does not turn off when a flashlight is shined on the light sensor for a few minutes, then the sensor may be faulty. Please contact customer service.

NOTE: Photocell (B) may have a few-minute delay, to reduce its sensitivity to sudden light changes. When testing shine a light/cover the photocell for a few minutes to check if the fixture functions properly

5-Year Limited Warranty

This is a limited warranty offered by Probrite for a period of five years from the date of purchase to its customers. Probate warrants to customers that the products will be free
from defects in material and workmanship. The obligation of Probrite under this warranty is limited to the provision of replacement of products and is extended to the original purchaser of the product on presenting valid purchase receipt or other proof of date of original purchase acceptable to Probate. A receipt is required for rendering the warranty performance. Any warranty claims without original proof of purchase would not be accepted.
It should be noted that the warranty does not apply to Probrite products that have been altered or repaired by unauthorized personnel, have been subjected to neglect, abuse, misuse or accident, or damages caused during shipping. Any other products not manufactured by Probrite which have been supplied, installed, and/or used in conjunction with Probrite products are not covered under this warranty. Any damages caused by replacements bulbs, LEDs, or corrosion or discoloration of brass components are also not covered by this warranty.
Limitation of Liability:
In no event, Probrite shall be liable for indirect, consequential, incidental, or special damages, or lost profits. Probate is not liable for any claims or damage arising out of or connected with the manufacture, sale, delivery, use, maintenance, and repair or modification of Probrite products, or supply of any replacement parts that, exceed the purchase price of Probrite products giving rise to a claim. Labor charges to remove or install the fixtures will not be accepted.
To Claim:
Please contact PROBRITE customer service at 1-844-507-5651 or email [email protected] and include your name, address, and contact number, along with a copy of the purchase receipt and a brief description of the problem.

Questions? / Missing Parts? / Need Accessories?
Before returning to the store, call or email PROBRITE
Customer Service 9 am-5 pm EST Monday to Friday.
1-844-507-5651
[email protected]
PROBRITE.COM
RETAIN THIS MANUAL FOR FUTURE USE
Para las translaciones en español,
visit www.probrite.com/install
Visit www.probrite.com/install for installation video tutorials and product support
PROBRITE.COM
Please call 1-844-507-5651 or email [email protected] for further assistance.

Read User Manual Online (PDF format)