ggm gastro GKE550LED Beverage Refrigerator User Guide
- June 13, 2024
- ggm gastro
Table of Contents
gm gastro GKE550LED Beverage Refrigerator
Dear customer;
To increase efficiency of your cooler, before using it we strongly recommend
you;
- to read the whole guide
- keep the guide as a source
- to use the cooler according to guide instructions.We want to remind that, we will be not responsible for the damages that depends on the incorrect usage or instruction disobedience. For damage and information issues, please contact GGM Gastro International GmbH.
The product will also be out of warranty, if someone other than authorized service interferes the product directly. The aim of this cooler is keeping the beverages and foods cold. We will also be not responsible if you run the product out of this purpose.Thank you for preferring us and for your trust.
- The operating temperature range of the cooler is between 1 and 10 degrees.
- The product does not contain Asbestos, formaldehyde, cadmium and CFC materials
- Compressor oil is based on none PCB and PCT.
- The refrigerant gas is R404a, R600a or R290a, which is is proper for KYOTO protocol.
- This device is also proper for WEEE (Waste Electric and Electronic Equipment) regulations
TECHNICAL FEATURES OF THE COOLER
Gross volume | 550 LT |
---|---|
Net volume | 537 LT |
Internal dimensions (WDH) | 544x636x1594 |
External dimensions(WDH) | 670x835x2140 |
Refrigerant | R600 |
Operating temperature | +1 °C / +7 °C |
Voltage/Frequency | 220-240 V / 50 Hz |
ATTENTION
The products that shown in this guide, are designed and produced according to National and International security norms. For safe and secure usage, following issues must be considered.
- Check the socket, whether it is suitable or not. A grounded socket is must.
- Make sure your structure wiring. Do not use sockets that are not fixed. Extension cable and multiple sockets are not advised. If it is an obligation, beware of voltage and cable diameter.
- If the electrical connection is damaged, the replacement must be done by authorized technical service. While running, if you have a hesitation concerning electrical connection, call the authorized service.
- When unplugging, hold the knob of the socket, never hang from cable.
- External covers must not be removed. Otherwise, dangerous parts and sections will be accessible.
- Never use pressured water. It may cause damages in electrical parts.
- A defection may come from cooler electrical system or building electrical installation. For both, do not intervene to cooler directly. Unplug the cord, call the nearest service.
- Never plug and run a damaged product (like a transport damage) Please contact to service.
- Consider the maximum loading capacity. Do not pass the loading line.
- Replacement of electrical parts must be done by authorized service.
- Keep package materials somewhere, that none-adults can reach. Package items (nylon, Styrofoam etc.) may be dangerous for nonadults or children.
- For children and non-adult person usage, viewer discretion is advice.
- For interior or exterior cabinet, always use materials that producer advise to use.
- If an intervention is need, please contact to authorized service.
- Never carry or move your cooler while it is plugged. Mending or maintenance must be prevented.
- Obey the locate rules. To not to obey shutters and grids locations, may cause fires.
INSTRUCTION FOR CARRYING
- If possible, carry the cooler with a forklift or a hand lift.
- If you have a no lift, carry the cooler with enough person in a stable position.
- While carrying the cooler always use gloves.
- While carrying the cooler, just handle from wooden pallet. Never use front or back protection wires.
NEVER LIE THE PRODUCT ON SIDE
INSTRUCTION FOR INSTALLATION
- To remove the pallet, cut the plastic clamps.
- At least three man should lower the cooler, as shown in the picture.
- Make a stable pushing. Between cooler and wall, there must be min 15 cm gap.
- After allocated the cooler, you should wait for three hours. In this moment, compressor oil will be balanced. Than you can plug it, the first run must be when te cooler is empty.
- The protective film should be removed (if it exists).
- By using adjustable feet, make the cooler stable. Avoid gaps, prevent vibration.
- Compressor group air inlet must not be prevented. This is the most important issue. Allocate your product that it will be parallel to the ground, no aim is required. Adjustable feet and rollers must touch the base. The distance between compressor group and wall is important. More distance, provides increasing performance. For that reason, at least 15 cm gap is required.
- After transport of the cooler, before operating it, you should wait for four hours.
- The first running must be done when the cooler is empty. Loading can be done after this period.
- Connection of the cooler must be checked by experienced electrician. The fuse height must be 170 cm.
- For fault current, electric connection must be supported with 30 mA fuse.
- The cooler must be also provided with the nearest ground.
USAGE FOR THE COOLER
Temperature of the cooler is calibrated for the most proper conditions. The
operating temperature can be adjusted from the digital thermostat. We advice
you to keep them with default factory value. Internal temperature of the
cooler can be adjusted between +1 °C and +10 °C. Digital thermostats have
default factory values, and no need adjustment. Thermostats may have many
programs within (eco mode, night mode etc.) If you have a problem with your
cooler, please contact to service. Failure codes are listed in failure
section. If you get any of these, stop the alarm of the thermostat and inform
the service. There is no a private defrost process in your cooler. Although
your products prevents snowing, high humidity and temperature may cause
snowing rate. Operating time depends on snowing, which also means energy
consumption will rise. At this position, stop the working and clean the snow.
DO NOT FORGET! UNFROZEN EVAPORATOR PROVIDES BETTER EFFICIENCY.
BEFORE CALLING SERVICE & CLEANING
BEFORE CALLING SERVICE
INTERNAL CLEANING
Remove beverages. Wait for the internal temperature that it will be same with
environment temperature. For cleaning and maintenance use a protection glove,
this will protect you from injuries. Remove the accessories. Use a soft cotton
linen with warm soap water .For drying, use cotton based linen. For first
operating, wait for two hours. Than you can reload your beverages.
EXTERNAL CLEANING
Use a cotton base linen with warm water. Avoid water from front control panel
or lighting departments. For door gasket, just use clean water with soap.
www.ggmgastro.com
CONTACT
Weinerpark 16 48607 Ochtrup (DE)
+49 (0) 2553 722 01 00
info@ggmgastro.com
References
Read User Manual Online (PDF format)