Wagner AL8010F Refrigeration or Heating Digital Thermostat User Manual

June 6, 2024
Wagner

Wagner logo

Wagner AL8010F Refrigeration or Heating Digital Thermostat

AL801 Of is a digital thermostat based on Set-point & Hysteresis to control the power supply status of connected loads; with just one Relay too, viring a refrigerator or a heate£, the set-point temperature”e ranges from -50 to 120 °C.

Package

  • Controller: 1PCS
  • Fasteners: 2PCS
  • Sensor: 1PCS
  • Manual:   1PCS
  • Wate, proof cover:   1PCS

Specification

  • Input Power: 220V AC± 10% 50/60HZ; (12124/48/1 I0V Option)
  • Maximum current: WA (Default) 1m.der 220V AC
  • Sensor:   NTC, 25°C 110 K.Q, the sensor cable 200cm
  • Protection Class:   .si!P6 5 t-0 the front panel
  • Storage: -l 0°C – 60°C, RH <90%, without condensation
  • Measurable Range: -5O°C – l 20°C
  • Controllable Range: -5O°C – l 20°C
  • Resolution: 0- 99.9″‘C is 0. l °C, ofuer range 1 “C
  • Accuracy: ± I 0c
  • Power Consumption: W n3.

Interface & Operation

IFront Panel & Icon
Under normal status

  • When screen light, Hold  the II key for Js to tum off the controller;
  • When the screen is dark, press the II key to light on the semen.Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-1

Indicator/ character in the display

Indicator Meaning On Hide Wink
Wo rk Working status of the load load Working Stop Delay
set Selling status On Set Non-setting N/A

Dimensions & InstallationWagner AL8010F Refrigeration or Heating Digital
Thermostat fig-2

  1. Suggested amount dimension: 71 “’2985mm (\VH*D)
  2. Detach the slide fasteners, put the controller to the hole, wiring follow the diagram
  3. InstaU the fasteners and the wate1prnof cover.
  4. Please avoid installing in the below environments:
    • Relative humidity > 90%. have condensation
    • The places that temperature <-10°C or >60°C;
    • The places that have inflammable and explosives;
    • Strong vibration or struck
    • Exposed to the continuous water mist spraying;
    • Exposed to the dust;
    • Exposure to corrosive and pollution gas (eg, the gas, smoke, or salt fog)
    • Wireless electromagnetic interference or s•trong magnetic fields (near to transmitting antenna or switch: board room).

Wiring D1iagram

The input power voltage of the load and the controller could be different.Wagner AL8010F Refrigeration or Heating Digital Thermostat
fig-3

  1. OK NTC sensor, need not distinguish + or – when wiring it.
  2. The input voltage must be the within die range of Marked Voltage ±10%.
  3. Load! Power Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-2.0
    • The factor for Inductive Load like compressor, heating pump, usually be 5-8;
    • The factor for Resist:I’ve Load like Electric heating rod, Electric blanket usually is 1.5 – 2;
    • The factor for Incandescent lamps usually is 15.
Wiring Diagram

Wagner AL8010F Refrigeration or Heating Digital
Thermostat fig-4

  1. HDK NTC sensor, Need not to distinguish + or • when wiring i.t
  2. The i.nputt voltage must be within the voltage value malice in diagram ± l 0% value.
  3. Load PowerWagner AL8010F Refrigeration or Heating Digital Thermostat fig-2.0
    • Th – factor for Induction.ve Load ll\:e c.ompli so:r, beating plump, usual y IDe:5~8 ·
    • The factor for Resistive Load like Electric heating rod Electric blanket usually is L:5~2
    • Th factor for Incandescent la1np, 111.Sua]ly is 1:5.
Configurations

Code ‘ and Function on Menu

Code Function M i n Max Defualt Step
H[ Heating ,or Cooling [ H [
d Rerut’i:lJ Diffe.renre (“C) 1 15 .5 1
ts Lowest set Limit (“C) -50 ATV -50 1
HS Highest Limit (“C) ATV 120 120 1
[R Temperrature Calib ration (“C) -5 +5 0 1
Pt De.la; Time Min) 0 10 1 1

What is ATV and how· to sec It?

ATV means Aim temperature value which is the ideal temperature you wish to reach. once exceed this va]ue (if difference value = 0) the status of load. will be changed, Details of setting as follow

step1 :Assure power on P11 .s and release key once times you will find disp]ay blink a data which is changeable.
step2:· now press the o:r keys to get you aim value·

  • press and bold on the o:r is fast forward function;
  • the length of the step is 0.1. “C;
  • The editable range between lower and higher ]imit
  • The buzzer will scream once Roon. Temperature   or Room temperature press any key to stop screaming if you want to.

Step3: Waiting for 1Os the device will save data automatically or press to save it

Error & Alarm

When an alarm occurs if the readout flashes —and buzzer sounds

  • Press any key to stop buzz scream
  •  Check the room temperature and then change the compressor I heater working status manually i
  • necessary,
  • fix o:r replace the sensor; aft r bat screen wi]l back to manual slate
  • And older c.ode lease, r-efere1100 below content to fix the problem.Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-19