MOTEPRO WH-200 4G Gate, Barrier Shutter User Manual
- June 13, 2024
- motepro
Table of Contents
WH-200 4G Gate, Barrier Shutter
Product Information
The 4G Gate, Barrier, Shutter, Garage Door and Door opener is a
device that allows users to remotely open gates or garage doors
using their mobile phones. It operates on 4G networks and can work
worldwide without any call charges. The device rejects calls from
unauthorized numbers and provides SMS feedback confirmation. It
also remembers the relay status in case of power failure. The
device has one output with a relay for connecting to the switch of
the door or machines. When the relay is activated, a SMS
confirmation is sent to the owner. The device also has a wired
switch for manual control. It is suitable for various applications
such as gates, bollards, barriers, garage doors, shutters, and
access doors or machines.
Technical Specifications
-
4G Frequency: Supports various 4G bands for different
regions -
DC Power Supply: 9-36V DC/1A
-
Power Consumption: Max. 50mA/Average 25mA
-
SIM Card: Nano type, 3V
-
Antenna: 50 SMA
-
Relay: 3A/250V AC | 20A/14V DC
-
Users: Supports up to 200 users
-
Operating Temp: Refer to user manual for specific range
-
Relative Humidity: Refer to user manual for specific range
-
Dimension: Refer to user manual for specific dimensions
-
Net Weight: Refer to user manual for specific weight
Interface Instruction
The product interface includes the following indicators and
connection terminals:
-
INDICATORS
-
ANT: Connects to the 4G antenna
-
Signal: Flash per 1 second (quickly) indicates registering to
cellular network. Flash per 2 seconds indicates normal status. OFF
indicates inability to connect to SIM card or unregistered to the
cellular network. -
Relay Reset: Indicates relay status and turns on when a call is
received and relay is activated. -
Run: OFF indicates inability to connect to SIM card or
unregistered to the cellular network.
-
-
Connection Terminals
-
Power supply input, Positive wire (+)
-
Power supply input, Negative wire (-)
-
Relay Output: + NO (Normally Open port) and COM (Common port) –
Connects to the switch of the electric lock or device -
Relay Output: NC (Normally Close port) – Connects to the switch
of the electric lock or NC device -
Switch: Dry contact, used to be connected with wired switch,
like push button. Should not be connected with voltage input.
-
Product Usage Instructions
Before installing the control unit, it is recommended to test
the system including power supply and 4G signal.
SMS Configuration Guide
Please refer to the document of WH-200 SMS Command Set for
detailed instructions on configuring the device via SMS.
Example Application Setup
To set up an authorized phone number, follow these steps:
-
Authorized phone number: 987654321
-
Send the following command to WH-200 by SMS:
1234#TEL987654321#001# -
Now, you can use the phone number (987654321) to call WH-200
and control it.
Installation
1. Insert the SIM card into the control unit.
4G Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage
door with a FREE call from your mobile phone! Remote switching machines with a
FREE call from your mobile phone!
User Manual WH-200 V2.0
I Preface
Thank you for using the WH-200.You will know well about the functions and
operation methods of this product quickly through this User Manual. This
product is mainly used for remote control application based on 4G
network.Please use it according to the parameters and technical specification
in the User Manual.Meanwhile,the Notes shall be considered for usage of radio-
control products,especially 4G products.Our Company bear no liability for
property loss or bodily injury arising from abnormal or incorrect usage of
this product.
Packing List
II Induction
The 4G Gate Opener WH-200 is a very simple device which can be used for
authorized door access, controlling gates, switching of remote equipment, car
parking systems. WH-200 can be used in places which requires turning ON/OFF
your system, machines, equipment remotely with a FREE call from your mobile
phone . Just dial from Authorized User number then the Barrier and doors are
opened, or the machines are turned on or off. There are no call costs, WH-200
rejects the call from authorized number then carries out the turn ON/OFF
action.
Features
4G Quad-band, can work in the worldwide 4G networks. No call charges. The 4G
Gate Opener rejects the call from authorized number, then
the relay will turn ON/OFF on the first ring. Secure – Using caller ID for
identification, unknown callers are ignored. Can be operated from anywhere, no
distance limit. Add or remove users by SMS Text command or APP. Up to 200
(Optional 1200) authorized phone numbers can be configured. Time limitation
for access,user can call in to control only during the pre-set time period.
Automatically report current status by SMS or call to the 1 st number. The
relay close or open time is programmable.
The SMS Feedback confirmation is programmable. Remember relay status when
power failure. One output with relay for connecting the switch of the door or
machines. The relay action will return a SMS confirmation to the owner, this
function is editable. One wired switch:we can control it under manual control
mode. Based on 4G Network, applied to many application.
(gates, bollards,barriers, garage doors,shutters and access doors or
machines).
Technical specifications
Parameter item Reference scope
4G Frequency
DC
Power
Supply
Power
consumption
SIM Card
4G-EU(For EMEA):
LTE-FDD Bands: B1/B3/B5/B7/B8/B20/B28 LTE-TDD Bands:B38/B40/B41 GSM
:850/900/1800/1900M H z 4G-AU(ForLatin Am erica/Australia/N ew Zealand): LTE-
FDD Bands:B1/B2/B3/B4/B5/B7/B8/B28 LTE-TDD Bands:B40 W CDM A:B1/B2/B4/B5/B8
GSM :850/900/1800/1900M H z
9-36V DC/1A
Max. 50mA/Average 25mA
Nano type, 3V
Antenna
50 SMA
Relay
3A/250V AC | 20A/14V DC
Specification
Users
200
Physical Layout
Parameter item Wired Switch
Reference scope Supports
Relay Type
Relay Time
Operating Temp Relative Humidity Dimension
Net Weight
NO/NC Max. 9999s – 10 + 60 10 90RH 85×61.5×25mm 208g
Interface Instruction
INDICATORS
ANT
Connect to 4G antenna
Signal
Flash per 1 second (quickly): registering to cellular network. Flash per 2 seconds: Normal status. OFF: can not connect to SIM card or unregistered to the cellular network.
Relay Reset
Relay Status, calling in, the relay will work, this LED indicator will on.
Press and hold the Reset button until the Run LED is always on, then after 5
seconds,,it will reset the WH-200 to factory default.If reset successfully,it
will auto restart after 8 seconds
Flash per 1 second: Connected the cellular network successfully.
Run
OFF: can not connect to SIM card or unregistered to the cellular network.
12V DC
Relay Output
+ NO
COM
Connection Terminals Power supply input, Positive wire.
Power supply input, Negative wire. Normally Open port. 3A/240VAC. Connect to
the switch of the electric lock or device. Common port. 3A/240VAC. Connect to
the switch of the electric lock or device.
Normally Close port. 3A/240VAC. Connect to the switch of the electric lock or NC device.
Switch
Dry contact, used to be connected with wired switch, like push button. Notice: It should not be connected with voltage input.
III Configuration guide of SMS
Please refer to the document of WH-200 SMS Command Set
Such as one of simple application
just setup 1 parameter: 1.Setup Authorized phone number example: Authorized
phone number:987654321 Send this command to WH-200 by SMS:
1234#TEL987654321#001# So we can use phone number(987654321) to call WH-200 to
control it
IV Installation
Before installing the control unit, please test the system firstly, including
power supply, 4G signal, etc.
1Insert SIM card into Control unit
In the backside of the unit ,please install the 4G SIM card
2Connecting the Electronic Lock or Electric equipment
V FAQ
The WH-200 fail to register the net.Please affirm the following parameters 1
The unit cannot support PIN Code Protected SIM Card 2 Sim card supports SMS
and voice function. 3 Contact the local network to check whether to support
the device’s frequency band 4 The 4G Signals are enough,Not too low .above 10
If the problem cannot be solved, please contact the distributor or
manufacturer.
The WH-200 can work normally ,but fail to send SMS to the first user number
you can try to add the country code before the first number(refer to WH-200
SMS Command Set ).When we add country code,we should add 00 or + before
country code.Such as 44( country code in UK),we should use 0044 or +44 as
country code in UK ,not 44.
WH-200 List of SMS Commands(briefly)
1 Introduction
1.1. Scope of the Document
This document presents the SMS Commands Set for gate opener WH-200
1.2. SMS Command Syntax
The pwd in the commands means the password, when you use it, please in stand
of it by the digital number; All commands must be CAPITAL Lock LETTERS .Don’t
add spaces or any other character. Add your country code before the phone
number, such as “0044” in UK
Basic syntax
pwd
1.3. SMS Command category
Read Command This command mainly inquire parameter values Write Command This
command sets the user-definable parameter values Execution Command This
command will control or reboot the device
Notice: The unit cannot support PIN Code Protected SIM Card If the command is
incorrect, the WH-200 will return: Command error, please
resend command
2 General SMS Commands
2.1 (MUST STEP)Set the SIM card number of the device
Syntax Write Command pwd#TELSIMcard Number#201# Response(s) 201:SIMcard Number
Parameter Description SIMcard Number
The SIM Card Number of the device Example:
1234#TEL66668888#201#
SIMcard Number:66668888
2.2 Set new password
Syntax
Write Command pwd#Pnewpassword# Response(s) New Password:xxxx
Parameter Description xxxx
The original password is 1234 Password must be 4 digits
Example: 1234#P6666#
change 1234 to 6666
2.3 Set authorized number
Inquire authorized user’s information Syntax
Read Command
1.By serial number: pwd#TELSerial Number?
2.By Phone number:
pwd#TELPAuthorized User’s Phone Number?
3.By user’s name:
pwd#TELAuthorized User’s Name?
4.By batch serial number: pwd#TELserial number start#serial number end?
Response(s)
Serial Number:Authorized Number Authorized User’s Name Fr:Start Time To:End
Time
Set authorized phone number(4 methods)
Write Command 1. Only Authorized phone number: pwd#TELAuthorized Number#Serial
Number# 2. Authorized phone number & user name: pwd#TELAuthorized
Number#Serial Number#Authorized User’s name# 3. Authorized phone number &
Start/End Time: pwd#TELAuthorized Number#Serial Number#Start Time#End Time# 4.
Authorized number & Start/End Time & user name pwd#TELAuthorized Number#Serial
Number#Start Time#End Time#Authorized User’s name#
Response(s) Serial Number:Authorized Number Authorized User’s Name Fr:Start
Time To:End Time
Remove the authorized number(2 methods)
Write Command 1. Just remove one user: pwd#TEL#Serial Number# 2.Remove batch
the Authorized Number: pwd#TEL#Serial Number Start#Serial Number End#
Response(s) Serial Number:Empty or Serial Number Start-Serial Number End:none
Parameter Description
Authorized Number
Authorized number means the one which can dial to control WH-200. Country code
must be neededbefore the country code we should add 00 or +,00 or + cannot be
omitted.
Highly recommend that the serial number of 001 is admin’s cellphone number,
because the relay action message and self-check auto report SMS message will
be sent to the first position cellphone number.
Serial Number
Serial Number is the position to store the authorized number, from 001~200
Serial Number must be 3 digits
Authorized User’s name
It is be regarded as remarks of the authorized phone number Authorized User’s
name must be CAPITAL Lock LETTERS,Max:10
Start Time & End Time
Start Time:the start time of this number can call in to control
End Time:the end time of this number can call in to control
End Time must be more than Start Time
Start /End Time format:YYMMDDHHmm
YY:year DD:day mm:minute
MM:month HH:hour
Notice:If authorized number is without start time and end time. Means this authorized number always can call in to control Eamples:
1234#TEL003? 003:008613500003333
1234#TELSAM? 003:00861350003333 SAMPLE
1234#TELP123456789? 003:66123456789
1234#TEL001#010? 001:00861350003333
1234#TEL008613500008888#001# 001:008613500008888
1234#TEL008613500008888#002#AB# 001:008613500008888 AB
1234#TEL8888#003#2006080901# 2006081002# 003:8888 Fr:20/06/08,09:01
To:20/06/08.10:02
1234#TEL6666#005#2006080901# 2006081002#JACK# 003:8888 JACK Fr:20/06/08,09:01
To:20/06/08.10:02
1234#TEL#004# 004:Empty 1234#TEL#001#010# 001-010:none
Inquiry the authorized number at position 3
Inquiry authorized number and name has the letters of SAM
Inquiry authorized number and numbers have 123456789
Inquiry authorized numbers from the position 1 to 10
Set 13500008888 as the first user number. Password is 1234.The 86 is country
code.00 cannot be omitted
Set 13500008888 as the second user Name:AB
Set 8888 as the third user number
20:year,2020
06:month
08:day
09:hour
01:minute
Start Time :2006080901
End Time :2006081002
Set 6666 as the fifth user number
20:year,2020
06:month
08:day
09:hour
01:minute
Start Time :2006080901
End Time :2006081002
Name:JACK
Remove the authorized number at position 4
Remove the authorized numbers from the position 1 to 10
2.4 Set the authorization of phone number
Syntax Write Command(Any phone number can dial to access the device) pwd#AA#
Response(s) C-Type:ALL
Write Command(Only authorized number can access it (Default)) pwd#AU#
Response(s) C-Type:AUT
Parameter Description
Warning! With the command(pwd#AA#), it will allow anyone to access the device
Examples:
1234#AU# C-Type:AUT 1234#AA# C-Type:ALL
2.5 Set the relay close time
Syntax
Write Command pwd#GOTClose Time# Response(s) R-Time:xxxs
Parameter Description
Close Time
Range:000-999.Unit:second.Default:1
0:relay will always keep close(ON) after call in until the next time the same
phone number call in
Examples:
1234#GOT02# R-Time:02s 1234#GOT00# R-Time:00s
2.6 Enable/Disable return SMS confirmation when relay activated
Syntax Write Command(Return ON/OFF SMS confirmation when relay activated)
pwd#R#
Response(s) R-SMS:ON
Write Command(Not return ON/OFF SMS confirmation when relay activated
(Default)) pwd#N#
Response(s) R-SMS:OFF
Write Command(Only return ON SMS confirmation when relay activated pwd#C#
Response(s) R-SMS:C
Write Command(Only return OFF SMS confirmation when relay activated pwd#F#
Response(s) R-SMS:F
Parameter Description
With the command(pwd#R#), when the relay action(close or open), the unit will
return a SMS confirmation to you(the first user number) Examples:
1234#R# R-SMS:ON 1234#N# R-SMS:OFF
2.7 Enable/Disable remember relay status when power failure
Syntax Write Command( Enable this function ) pwd#ER# Response(s) R-Rem:ON
Write Command(Disable this function (Default)) pwd#DR#
Response(s) R-Rem:OFF
Parameter Description With the command(pwd#ER#), when the device re-power
on,the relay will remain in the state before power lost Notice:If you want to
use this function ,The relay close time must be set 00
Examples:
1234#ER# R-Rem:ON 1234#DR# R-Rem:OFF
2.8 Enable/Disable SMS feedback when setting SMS command
Syntax
Write Command(Enable this function) pwd#FON#
Response(s) F-Back:ON
Write Command(Disable this function(Default)) pwd#FOFF#
Response(s) F-Back:OFF
Parameter Description With the command(pwd#FON#).When you set the write
command,if this command is be set successfully,the SMS confirmation will be
sent to you.If you do not want to receive these SMS feedback,you can disable
this function(pwd#FOFF#)(When you send the write command ,if the command
works.the Run Led will flash three times quickly.if not work,the Run led will
not flash quickly). if the command you set is read command.The device will
send SMS feedback to you,no matter the function is enable or disable Examples:
1234#FON# F-Back:ON 1234#FOFF# F-Back:OFF
2.9 Inquiry version number
Syntax
Write Command pwd#IMEI# Response(s) IMEI: imei number of device Version :
WH-200 V2.0
2.10 Set the device description
Syntax Write Command pwd#DTDescription#
Response(s) description
Parameter Description Description
You can add description with WH-200(such as install position,user
information),the description will show in SMS which WH-200 send to you.Max:20
Examples: 1234#DTMachine Room# Machine Room
2.11 Enable/Disable self-check auto report SMS or dial to the 1 st number
Syntax Write Command pwd#Cxx#yyy#z#
Response(s) C:xx,yyy,SMS/Call/None
Parameter Description The function is interval to report the current status by
SMS or call to the 1st Authorized number
xx The start time of sending the current status’s SMS
,unit:hour,range:00~23,must be 2 digits. Default:08.
yyy
The interval report time of sending current status’s SMS.Unit:hour.
Range:000~999,must be 3 digits,000:disable this function,default:000
z
The report type.range:0-3. 0:none 1:SMS ,2:Call, 3:SMS & Call.Default:1
Notice:If you select call ,if triggered,The device will call to the 1st
Authorized
number,if we answer it,it automatically hang up the phone after 3~5 second ,if
we
do not answer it ,it will call three times until we answer it
Examples:
1234#C08#024#0# C:08,024,None 1234#C08#024#1# C:08,024,SMS 1234#C08#024#2#
C:08,024,Call 1234#C08#024#3# C:08,024,SMS/Call
Start Time:08:00. Interval:24 hour Execute:Nothing Start Time:08:00.
Interval:24 hour Execute:send SMS to 1st Authorized number Start Time:08:00.
Interval:24 hour Execute:call to 1st Authorized number Start Time:08:00.
Interval:24 hour Execute:send SMS and call to 1st Authorized
number
2.12 Inquire current status
Syntax
Read Command pwd#EE#
Response(s) Current time of the device GSM signal value Current relay status
Total authorized numbers Enable/disable self-check auto report SMS or dial to
the 1 st number The authorization of phone number Enable/Disable remember
relay status when power failure The relay close time Enable/Disable return SMS
confirmation when relay activated Enable/Disable SMS feedback when setting SMS
command Enable/Disable automatically delete expired authorized phone numbers
The device description
Parameter Description
GSM signal value
Range:0~31,GSM signal quality. we suggest to keep the signal level above 12.
If it is below 12, please make sure you had connected with an external GSM
antenna, or take the device to a better open area where has a better GSM
signal.
Current relay status
ON:close.OFF:open Total Authorized number
Total number of Authorized numbers
Example: 1234#EE# 20/05/06,10:18:08 S:19 R-ON Usage:021
C:08,012,SMS C-Type:AUT R-Rem:OFF R-Time:01s R-SMS:OFF F-Back:OFF A-Del:OFF
Machine Room
20:year,2020. 05:month.06:day 10:hour 18:minute 08 :second GSM signal value:19
The relay is closed The device have 21 authorized
number Refer to the text above …
2.13 Control the relay ON/OFF by SMS command
Syntax
Exec Command(Control the relay close ) pwd#ON#
Response(s) R-ON
Exec Command(Control the relay open) pwd#OFF#
Response(s) R-OFF
Examples:
1234#ON# R-ON 1234#OFF R-OFF
2.14 Reset all parameters to factory default
Syntax Write Command pwd#RESET#
Response(s) Reset OK! It will auto restart after 8 seconds
Examples: 1234#RESET# Reset OK! It will auto restart after 8 seconds
Notice:The other way to reset all parameters to factory default is like this:
You can press and hold the RESET button for several seconds until the Run Led
is always ON, and then after 5 seconds ,it will reset the WH-200 to factory
default.If reset successfully,it will auto restart after 8 seconds
2.15 Inquire the Serial Number of authorized number
Syntax Read Command pwd#USER?
Response(s) Serial Number
Example:
1234#USER? 001 003-005 012
the Serial Number of authorized number : 001,003,004,005,012
Notice:When you do not know which serial number has authorized number ,This command is useful
3 List of SMS Commands(briefly)
Function
SMS Command
Meaning
Change password 1234#P6666#
Default is 1234 (4 characters)
Add new user
Add phone number to 2nd position of 1234#TEL0044777777#002#the user list. From
001 200. The “001”
is the Admin.
Check user’s position 1234#TEL005?
Check the 5th User’s Phone
Delete the user
1234#TEL#005#
Delete the 5th user in the user list.
1234#AA#
Anyone could open the door by CALL
Set the authorization 1234#AU#
Only authorized users could open the door
Set the relay close time
1234#GOT10#
Operate The door by 1234#ON#
SMS
1234#OFF#
The relay will close for 10 s.Relay time:000-999.Default:1;Unit:second Open
the door by SMS
Close the door by SMS
Inquire Current Status1234#EE#
Inquire Current Status
Reset all parameters 1234#RESET#
Reset all parameters
Notice:There are also many functional instructions, if you need please refer to the text above
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>