Q-TRAN QZ-PH-0-10V LED Power Supply Installation Guide
- June 13, 2024
- Q-TRAN
Table of Contents
Q-TRAN QZ-PH-0-10V LED Power Supply
Product Information
The QZ-PH/0-10V LED power supply is designed for use with LED light fixtures. It has a driver compartment and a wiring compartment for easy installation. The product comes in various wattages: 30W, 60W, 96W, 192W, and 288W. The QZ can be mounted vertically or horizontally and requires a stud for sufficient support. It has mounting tab slots and holes for secure installation. The power supply supports both phase dimming and 0-10V dimming.
Product Usage Instructions
- Mounting the QZ-PH/0-10V LED power supply:
- Place the power supply vertically or horizontally.
- Use the supplied #6 flat head screws to secure the power supply.
- Ensure the mounting tabs on the bottom of the enclosure are aligned with the mounting holes or slots.
- If mounting horizontally, use the center holes or side slots of each mounting tab for sufficient support.
- If mounting vertically, use the center holes or side slots of each mounting tab for sufficient support.
- When installing multiple QZ power supplies:
- Keep a separation of at least 3 inches between the enclosures to prevent the rise of ambient temperature.
- Wiring diagram:
- For phase dimming:
- Use a two-conductor cable for wiring from the power supply to the light fixture.
- Follow the provided wiring diagram for different wattages (30W, 60W, 96W, 192W, 288W) and the corresponding AC input, dim, and output connections.
- Ensure the phase dimmer wire (pink or grey) is connected correctly.
- For 0-10V dimming:
- Use a two-conductor cable for wiring from the power supply to the light fixture.
- Follow the provided wiring diagram for different wattages (30W, 60W, 96W, 192W, 288W) and the corresponding AC input, dim, and output connections.
- Ensure the phase dimmer wire (pink or grey) is connected correctly.
INSTALLATION
LED POWER SUPPLY – QZ-PH/0-10V
TOP VIEW Required Hardware Mounting Foot:
Mounting
- The QZ can be mounted either vertically or horizontally, utilizing the supplied screws and the mounting tabs on the bottom of the enclosure
- CENTER HOLE
- SIDE SLOTS
- The QZ must be mounted into a stud for sufficient support, using either the center holes or the slots of each mounting tab
- CENTER HOLE
- SIDE SLOTS
- When installing multiple QZ power supplies, separate the enclosures by 3” of space from edge to edge. This prevents the rise of ambient temperature between the power supplies.
- Horizontal mount illustrated above
- Vertical mount illustrated above
Wiring diagram
- Phase Dimming
- 0-10V Dimming
Wiring from power supply to light fixture must be two conductor cable
QZ 30W
- TOP VIEW
- WIRING COMPARTMENT VIEW
QZ 60W
- TOP VIEW
- WIRING COMPARTMENT VIEW
QZ 96W
- TOP VIEW
- WIRING COMPARTMENT VIEW
QZ 192W
- TOP VIEW
- WIRING COMPARTMENT VIEW
QZ 288W
- TOP VIEW
- WIRING COMPARTMENT VIEW
© 2023 Q-Tran Inc. All rights reserved 155 Hill St. Milford, CT 06460 203-367-8777 sales@q-tran.com www.q-tran.com
Specification is subject to change
Rev-08-09-23
References
- Your Name as Your Email | Hover Realnames
- LED Lighting Systems, Linear LED Lights, LED transformers | Q-Tran
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>