saxby lighting 78962 Surge Floodlight Instruction Manual
- June 13, 2024
- saxby lighting
Table of Contents
Instruction manual
Surge Floodlight
78962, 78964, 78966, 78968, 78970
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building
Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or
maintaining this fitting. Ensure other persons cannot restore the electrical
supply without your knowledge.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
The entire unit gets hot whilst on for a period of time.
This product is not suitable for location in or near a marine environment.
The external flexible cable or cord of this luminaire cannot be replaced. If
the cord is damaged, the luminaire must be destroyed.
Terminal block not included. Installation may require advice from a qualified
person.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distance between the junction box (not supplied) and the light
fitting.
Avoid locating any cables in positions that would cause a hazard. Position
cables and outdoor rated junction boxes (not supplied) away from areas where
they may be at risk from being cut, trapped or damaged.
This product is supplied with 1 metres of H05RN-F outdoor grade rubber
sheathed cable ready for connection to an approved, outdoor rated terminal
block which is not supplied and must be obtained. The mains supply cable must
have a minimum cross sectional area of 1.0mm 2 Cables must be protected using
suitable conduit or plastic trunking.
This is a floodlight product, and therefore should be positioned where it will
not cause a glare hazard.
Installation
Existing fittings must be completely removed before installation of a new
product. Before removing the existing fitting, carefully note the position of
each set of wires.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP
rating of the product.
Lights can install on the ground / wall or brackets according to actual
situation such as installation on the brackets with hexagonal head screw
fixed.And dig the hole on ground or wall with suitable expansion bolt (not
supplied) fixing according to light’s bracket if install on the ground or
wall.
Installed on the Ground
-
Hold the product in position and mark the location of the fixing holes.
The bracket can be removed from the fitting for ease of installation. -
Drill and plug the wall at the marked positions.
-
Use screw fix the bracket to the accessory “78970”.
-
Mount the product on the bracket and adjust the desired angle.
-
Wire as detailed wiring.
-
Refit the cover on the IP terminal block. Ensure that the seals are correctly located, and refit the screws.
Installed on the Wall
-
Hold the product in position and mark the location of the fixing holes. A minimum of two fixing points must be used.
Ensure the wall is capable of holding the weight of the product. The bracket can be removed from the fitting for ease of installation -
Drill and plug the wall at the marked positions.
-
Wire as detailed wiring.
-
Refit the cover on the IP terminal block. Ensure that the seals are correctly located, and refit the screws.
-
Fix the bracket to the wall using the screws and plugs (not supplied). Take care to avoid damaging any concealed wiring and pipes. The correct fixings should be used for brick or cavity walls.
-
Using the allen key (not supplied), loosen the bolts on the side, and adjust the fitting to the desired position. Ensure that the cable is not snagged. Re-tighten the bolts.
Wiring
Terminal block not included. Installation may require advice from a qualified person. Connect to an approved outdoor rated terminal block, observing the wiring diagram here.
Check that…
- You have correctly identified the wires.
- The connections are tight.
- No loose strands have been left out of the connection block.
Technical data
Supply Voltage: | 220-240 V~, 50 Hz |
---|---|
Bulb Type: | 78962 : 10W LED Module (SMD), 4000K 78968 : 50W LED Module (SMD), |
4000K
78966 : 30W LED Module (SMD), 4000K 78964 : 20W LED Module (SMD), 4000K
These products contain a light source of energy efficiency class F.
| Non-replaceable light source
| Non-replaceable control gear
| Conformity with all relevant UKCA Directive requirements.
| Conformity with all relevant EC Directive requirements.
| This product is Class 1, must be connected to earth.
| Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or
local store for recycling advice.
| This product is not suitable for dimming.
| This product is rated at IP65.
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive
cleaners as these could damage the finish.
For your safety, always switch off the power supply before cleaning.
This light source is protected by a shade. This part must be replaced
immediately should the shade become cracked or damaged. This fitting must not
be used without the shade in place.
For further information, please visit https://www.lighting-info.co.uk/78962
V4 07/01/2022
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg