PHILIPS Mini500 G4 Green Perform Canopy Instruction Manual

June 13, 2024
Philips

PHILIPS Mini500 G4 Green Perform Canopy

PHILIPS-Mini-500-G4-Green-Perform-Canopy-PRODUCT

Product Information

  • Product Name: GreenPerform Canopy Mini500 G4
  • Mounting Instruction: 444170264661 V2
  • Standards: GB IEC 7000, EN60598, IP65

Type Description:

  • BCP500 G4 LED85 PSU(PC)
  • BCP500 G4 LED125 PSU(PC)
  • BCP500 G4 LED140 PSU(PC)
  • BCP500 G4 LED180 PSU(PC)
  • BCP500 G4 LED85 PSD
  • BCP500 G4 LED125 PSD
  • BCP500 G4 LED140 PSD
  • BCP500 G4 LED180 PSD
  • BCP500 G4 LED85 GU5.3
  • BCP500 G4 LED125 GU5.3
  • BCP500 G4 LED140 GU5.3
  • BCP500 G4 LED180 GU5.3

Power (W):

Type Description Power (W)
BCP500 G4 LED85 PSU(PC) 53
BCP500 G4 LED125 PSU(PC) 79
BCP500 G4 LED140 PSU(PC) 91
BCP500 G4 LED180 PSU(PC) 122
BCP500 G4 LED85 PSD 58
BCP500 G4 LED125 PSD 85
BCP500 G4 LED140 PSD 96
BCP500 G4 LED180 PSD 128
BCP500 G4 LED85 GU5.3 53
BCP500 G4 LED125 GU5.3 79
BCP500 G4 LED140 GU5.3 91
BCP500 G4 LED180 GU5.3 122

Voltage (V):
The voltage range is 220-240V~.

Product Usage Instructions

  • To mount the GreenPerform Canopy Mini500 G4, follow the provided mounting instructions (444170264661 V2) in the user manual.
  • Ensure that you comply with the specified standards (GB IEC 7000, EN60598, IP65) during installation.
  • The product is available in various types, such as BCP500 G4 LED85 PSU(PC), BCP500 G4 LED125 PSU(PC), BCP500 G4 LED140 PSU(PC), BCP500 G4 LED180 PSU(PC), BCP500 G4 LED85 PSD, BCP500 G4 LED125 PSD, BCP500 G4 LED140 PSD, BCP500 G4 LED180 PSD, BCP500 G4 LED85 GU5.3, BCP500 G4 LED125 GU5.3, BCP500 G4 LED140 GU5.3, and BCP500 G4 LED180 GU5.3. Choose the appropriate type based on your requirements.
  • The power consumption varies depending on the type of product. Refer to the table above for the power (W) values for each type. The voltage range for the product is 220-240V~

For further details regarding CCT (Correlated Color Temperature), optics, frequency, glass dimensions, inrush current, and other technical specifications, refer to the complete user manual.

Mounting instruction

PHILIPS-Mini-500-G4-Green-Perform-Canopy-FIG- \(1\)

DIMENSIONS

PHILIPS-Mini-500-G4-Green-Perform-Canopy-FIG- \(2\)

Inrush Current

Model| Run current(A) @220V| Start (inrush)

current(A) /Ipeak(A)

| Start Current Duration(us) /

T(@50% of Ipeak) (us)

| *Touch current or Protective

conductor current (mA)

| Max. Num. of Luminaire on

MCB16A Type B(pcs)

| Max. Num. of Luminaire on

MCB16A Type C(pcs)

---|---|---|---|---|---|---
BCP500 G4 LED85| 0.25| 32.2| 405| <1| 8| 14
BCP500 G4 LED125| 0.375| 32.2| 405| <1| 8| 14
BCP500 G4 LED140| 0.43| 32.2| 405| <1| 8| 14
BCP500 G4 LED180| 0.565| 32.2| 405| <1| 8| 14

The leakage current *(touch current or protective conductor current) oof lectrical circuit may be greatly dependent upon electrical supply cables used suchsuchating and length, proper connection of electrical supply cables to luminaires, and wiring connection topology of luminaires to the supply electrical circuit amongst other site conditions.

  • In some cases referred to as Earth Leakage Current.

BCP500 G4 PSD/GU5.3

Mounting safety string

  1. Safety cable can be mounted for this luminaire

  2. Predefine the luminaire direction.

  3. Fixing surface mounting bracket

  4. Fixing luminaire

BCP500 G4 PSU (PC)

  1. 911401591832 ZCB504 frame clamp (locking ring)
  2. Fixing the locking ring on the mounting bracket
  3. Tighten the locking ring to the post
  4. Fixing luminaire on mounting bracket
  5. Proper use of the locking ringPHILIPS-Mini-500-G4-Green-Perform-Canopy-FIG- \(13\)

BCP500 G4 PSD/GU5.3

  1. Safety cable can be mounted for this luminaire

  2. Predefine the luminaire direction.

  3. Drill mounting bracket fixing hole

  4. Disassemble mounting bracket

  5. Fixing mounting bracket

  6. Connect power cable

  7. Fixing the luminaire to the right position

  8. Tighten the fixing screw

BCP500 G4 PSD/GU5.3 Optional Accessary Installation

  1. 911401591832 ZCB504 frame clamp (locking ring)
  2. Fixing the locking ring on the mounting bracket
  3. Tighten the locking ring to the post
  4. Fixing luminaire on mounting bracket
  5. Proper use of the locking ringPHILIPS-Mini-500-G4-Green-Perform-Canopy-FIG- \(27\)

Connect to Power Cable

  1. PSU version
  2. PSD version
  3. GU5.3 version

For controllable luminaires, basic insulation has been maintained between LV supply and control conductors (PSD version). Please use an external LED driver(SELV, Uout 30Vdc) whose insulation between LV supply and output shall be at least double insulation and reinforced insulation (GU5.3 version)

Application MR16 choice (GU5.3 version)/MR16(GU5.3)

Philips MASTER LEDspot MR16 LV 6.5W 3000K 12V AC 24D 660mA

In case the luminaire doesn’t work as normal, the MR16 lamp will be powered on with an AC12V the power supply. MR16 lamp is not included in the package

Warning

  1. The luminaire shall be installed by a qualified electrician and wired by the latest IEE electrical regulations or national requirements.
  2. Turn off the power supply before checking, installing, or moving.
  3. Before use, external earthing is required. Earthing is also required in its whole life.
  4. If any abnormal to be found or operation problem. Be sure to switch off the power first and contact your nearest Philips dealer.
  5. The Luminaire must be used within the applicable product specifications, installation instructions, and environmental conditions for storage & operations according to application guidelines provided by Signify for the product Warranty to be valid.
  6. The corrosive atmosphere or hazardous materials such as sulfur, chlorine, phthalate, etc must be avoided during the use and storage.
  7. The manufacturer will not take responsibility caused by improper use or self modifications ofself-modificationsnarie must be useLuminariaotective cover. Plea ase replace any cracked protective cover.
  8. Please inform yourself about the local waste disposal, separation, and collection syste,m for electrical and electronic products and packaging. Please act according to your local rules and do not dispose of your old product and of packaging with your normal household waste. The correct disposal of the packaging, your product, and/or batteries will help prevent potential negative consequences for the environment and human health. Batteries should be disposed of separately from the municipal waste stream via designated collection facilities. When disposing of a product that contains non-user replaceable batteries, the non-user replaceable batteries shall be removed by a professional.

Application Environment

  1.  For Indoor use only.
  2. The height between the luminous surface and groundthe  is suggested to be more ththe an 2.5mis ; the height between the bottom of the luminaire and the mounting surface must be more than 0.3m.
  3. Luminaires don’t have any evaluation on additional protection measures to prevent luminaires from high-altitude falling and windproof structures, can’t be used as flood and tunnel luminaires.
  4. Not suitable for use in harsh vibration and often causing vibration or swinging environment. Also not suitable for areas prone to hurricanes and extreme winds.
  5. Not use this luminaire with a PC cover in an environment that will corrode the PC, for example, ethylamine, tetrachloroethylene, etc.
  6. This product contains a light source of ener,y efficiency class: D.

Maintenance

  1. Periodic cleaning of the luminaire optical lens cover will ensure maximum optical efficiency. Luminaire shall be cleaned with a dry soft cloth only.
  2. The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualmanufacturern.
  3. Do not use acid or alkaline cleaner to clean this luminaire with a PC cove
  4. Please replace the protective toughened glass of the luminaire with glathe ss cover immediately when it is broken.

All the with ars and requirements in Chinese and English shall prevail. Other language is only for reference.

Signify (China) Investment Co., is Ltimage ress : Building 9 #, Lane 888, Tianlin Road, Minhang District, Shanghai City, P.R. China Postal code : 200233
Data subject to change without notice

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals