Dear users,
The instructions introduce the function characteristics of this product,
operation steps, notes and maintenance in d- etail.
In order to ensure that you can use the product more effec- tively, please
read this manual carefully before use and k- eep it safe after reading.
Without permission, cannot take apart products in person , otherwise, you will
lose the warranty.
Be careful, the company reserves the rights to update pro-ducts and
technology. Some illustrations in the specifica-tion you see in the product
may be different, received in -kind prevail.
Thank you for purchasing eur products, wish you use happily.
Without reading this manual, please don’t operate the pro- duct. If you have
any questions on the understanding of t-his manual, please contact the seller
or after-sales techni- cal personnel, don’t take action to operate the
product, or it may result in serious personal injury or property damage.
Note
Safety Precautions
To prevent blackouts or household oxygen bar may break down, someone who are
urgently needed oxygen must be configured with a much-needed backup support to
other devices (such as: oxygen cylinder, oxygen bags, etc.), it is not
considered for the life of the equipment or the use of the co- ntinuation of
life.
Oxygen may cause combustion, no smoking when operating the oxygen bar When in
a heat environment, sparks and open flames and other factors, do
not use household oxygen bar.
There is high-voltage in household oxygen bar, please do not disassemble.
All parts of the product, after rigorous testing, safety and reliability, so
do
not use this product with other accessories made by other manufactures ot-
herwise it will affect the performance.
Moving household oxygen bar by the cord or hose is prohibited.
This product with rated voltage of 220V,D110V, please use secure socket P
qualified.
To prevent accidents, do not let children operate the oxygen bar. When b-
reathing oxygen, not let the hose around the neck. When the elderly using the
oxygen, a guardian must beside him.
Houschold oxygen bar works as a direct separation of oxygen from air, w- hich
is used for breathing, so do not use in smoke, toxic and harmful gases
environments.
Cautions:
Before the first use, please roll household oxygen bar, then cut off the bo-
ttom of the transport fixed ties, see “Cut ties description”.
When this product is working, there will be intermittent exhaust sound, which
is a normal phenomenon.
When add water to wet cup, do not exceed the maximum water level. Wh- en
handling household oxygen bar, need to pour out the water in wet cup, so as
not to cause backflow.
Please confirm whether the oxygen outlet, the air intake vents behind ox- ygen
bar is blocked, in order to avoid downtime caused by high temperature.
This product only applies to household oxygenating, cannot be used as medical
treatment.
Product Features
Product Introduction
This product uses the air as raw material. ACD 220V01110V power as power
source. uses agood original zeolite by French and the air compressor 5000
hours lifespan, Through advanced pressure swing adsorption separation in room
temperature, extraction of high-purity oxygen by air, stable oxygen, safe and
reliable, this method is called pure physical methods. ( Refers to working
principle on p- age 12) .
Functional characteristics
Intelligent Control:
IMD beautiful large color panel, easy to operate, large color LED screen, cl-
ear display, timer operation function and with infrared remote control, let it
be easier and more convenient.
Anion:
This machine is equipped with ion function, and a “negative” button; the neg
ative ion system can work alone , you can also work simultaneously with the
oxygen system;Anion generatorAir vents located in the machine, the exhaus t
vents discharged into the surrounding space of the machine when working.
Multi-layer filter, self-easy to replace:
The oxygen system of this product has coarse dust filter, fine dust filter and
three bacterial filtration treatment for the input air respectively, finally,
the oxygen is fresh and clean after filtering , and the two front layers
filter can be replaced without disassembing, the user operate it comfortably.
Using environment
Temperature: 5-35 Relative humidity: <80%
Range of the atmospheric pressure: 0.086 MPa -0.106 MPa
When the temperature is higher or lower, do not use oxygen bar.
Technical parameters
Product name: household Oxygen Bar
Model: MAFO15A MAFO15AW
MAFO1SBW MAFO15B)
Scope of application: use as household oxygenating, not use for medical
treatment
PSA methods: PSA
The input power: 115Ww
Rated voltage: AC 220 v, 50 H2 AC 110V, 50H
Current rating: O.5A
Air output: 1~6L/min
Output pressure: <100kpa
Negative oxygen ion: ≥ 6 million particles/ cm’
Noise: about 48dB
Product size: 302 168 325mm
Net weight: 5.2kg
Electrical categories: ]] Execution standard: GB4706.1-2005 Q/MAF 01-2017
Functional difference showed in the following table
Model | MAF015A | MAF015AW | MAF015BW | MAF015BJ |
---|---|---|---|---|
Oxygen concentration | 30%–90% | 30Von-90% | 30Vog-90% | 30%~90% |
Remote control function | Yes | Yes | Yes | Yes |
Spray function | No | Yes | Yes | Yes |
Cumulative function | Yes | Yes | Yes | Yes |
Installation and Operation
Opening instructions
Oxygen packing, please check the items in the box whether they complete or in
tact according to the manual attachment list. Otherwise, please contact reta-
iler or manufacturer.
Appearance diagram: Opening instructions
Power operation and components using
Wet cup (add water): Use left hand to hold wet cup, use right-hand to grip and
rotate wet cup coun- terclockwise, lid open after the rotation in place,
adding moderate amount of pure water, then close the lid and turn clockwise
rotation in place.
Use of wet cup; Note: “The machine connected to the
outlet of which ends with the wet cup white tube”
Put one end of the conduit to the wet cup inlet port B (with the inlet
conduit, as difference) A is inserted into the other end of the conduit
connected to the ox- ygen outlet of household oxygen bar, and finally the end
of the oxygen duct p- lug to the integrated water heater outlet E.
When the water level inside the wet cup exceeds the maximum water level D,
please promptly drain the water to avoid water back into the oxygen tube.
Connect the power cord, power on
Put the tail end of the power cord into the power cord socket household oxyg-
en bar, and the other end connected to the indoor outlet, after power, the
power switch is turned on, after the first power, microcomputer will
automatically start the self-test all the bright lights of a display about 2
seconds , colleagues buzzer will sound prompt, after the self-test,
automatically restore the standby mode and displays the default time “015”,
“power jack” and “power switch” position, see section appearance of page four.
Power on: ON/OFF button
In standby mode, press the “ON / OFF” to wake up the machine and start wo-
rking, and “oxygen” light will be lit, the default length of 15 minutes, turn
off the machine by complex back to standby.
Time
Press “+, -” button to adjust the time of work time, after finish setting,
press t- he “On / Off” button, the oxygen machine starts to work. (after the
setup is co- mpleted, wait three seconds, the oxygen machine will
automatically start wo- rking)Click the “timing” until showing the length of
time.After finish working , the display window will return to standby mode and
waitsfor the user to use:
If you do not use for more than ten minutes (temperament cooling system is ru-
nning for about five minutes), it will enter power-savingsleep state (anion is
closed ), then “Power” will flash to alert the user who can press the power
swi tch back to the off state.
Anion
According to users’ needs, you can open anion function, click “anion” to open,
and display “anion” light will be lit (see screen instructions on page five),
pre- ss twice means close.
Remote control use With a dedicated remote control, this product
gets the remote control align- ment infrared receiver hole of oxygen machine
panel.
When you find the remote control operation insensitive and cannot operate, you
must check the remote control battery whether it fully charged first; re- mote
control can’t be too far from the host computer, otherwise it will lead to the
remote control operation insensitive.
Routine maintenance
The oxygen machine has smooth appearance, glossy, please prevent the sharp
scratch it.
Please turn off the oxygen machine after finishing the timer and the air s-
upply, and unplug the power in time.
The cotton filters on the host side change in time, if the cotton filters we-
re blocked by the dirty stuff, it will have an effect on oxygen.
Attention:
Please don’t take apart the machine by yourself, avoid unnecessary dam- age
inside the machine, before cleaning and maintaining, oxygen machine must be
cut off the power.
Handle of long idle
Remove the wet cup, drain the water out of the cup and replace host comp- uter
after air-dry.
Starting up, let the oxygen machine work for thirty minutes, then wait for it
to cool by natural.
Cutoff the power, replace the oxygen machine into the box.
Remote control can’t install battery while sealing, in order to prevent the
battery leakage to damage the remote control.
Pls wrap and seal the main engine with plastic bags to prevent air humidity
cause the machine performance degradation.
Parts maintenance
The maintenance of wet cup:
In order to ensure the cleaning of the wet cup, the injection should be pu- te
water or boiled water, and try to replace every day, we suggest users c-
leaning the wet cup once a week
Cotton filters and filter maintenance:
The main function of the filter is filter and adsorption the dust and im-
tp!purity, it will form a blockage in turn to affect the intake of oxygen
machine for a long time.
It will become intake block for a long time, thereby, have an effect on the
oxygen machine; generally, replaced once a quarter, if it has much dust,
recommend replacing every two months.
Problem Investigation Trouble Shooting
Symptom | Possible Cause | Solution |
---|
Household oxygen bar cannot operate properly, the power indicator light is not
bright.| The power line is not conne- cted to a power outlet.| Check whether
the socket outlet connection is normal.
Power supply socket without electricity.| Replace the electric socket.
Overload protection burning fuse| Open the insurance and replace the fuse.
Power cord is not for good in the household oxygen bar or power cord bad.|
Unplug reinsert the fuselage outlet or replace a power supply cord.
The screen display normal, but the oxy- gen bar does not have normal operation
soon.| Household oxygen bar over- heating protection.| Make sure the place has
been away from household oxygen bar curtains, bake warm m-achines, heaters and
fireplaces, and confirm household oxygen bar and walls or other o-bjects
around the retention gap of at least 20 cm.
Household oxygen bar coin- puter froze plate.| Turn off the machine, wait five
minutes to restart.
The compressor function b- reakdown.| Contact household oxygen bar retailer or
manufacturers.
Full screen flash, while alarm.| Internal hardware damage| Returned to the
manufacturer or dealer for repair.
Big Noise| Ties are not cut, the machine did not put a smooth.| Cut ties, put
the machine steady.
The screen display normal and hear normal operation sound but no anoin o-xygen
output.| Intake window cotton filters is dirty, cause block.| Household oxygen
bar internal malfunction.
Cut off the power switch, replace window air intake fiHer cotton.| Contact the
household seller or manufacturers.
Press to adjust the time when the tra- nsfer is invalid.| Sleep tone when keys
are lo- cked, inoperable.| Press the “On / or button to wake, the key to
adjust the time and then tune.
Symptom| Possible Cause| Solution
---|---|---
The oxygen machine emits pool bared s- ound six-minute int- ervals.| The
machine emits exhaust sound.| If the machine emits poof bared sound reg-
ularly is a normal phenomenon, discharge the sound of nitrogen.
Water coming out of the mouth of o- xygen.| Adding too much water in the wet
cup ( exceed the highest water level ) . airflow will push oxygen tube
blisters.| The water in the wet cup have reduced to the highest water level.
Difference temperature , ca- use the humidified oxygen in the wall that
moisture will c- ondense water out of cold.| Pour the water out of the wet
cup, starting up, after fifteen minutes ,waiting the droplets are dried in the
oxygen tube, then adding water into the wet cup.
the machine is op- erating normally – after starting up, but have a narrow
minded.| Flow value is too small.| Turn up flow
Wet cup Is not installed correctly cause leak| 1.wet cup cover is not fit in
place, unscrew the lid anticlockwise, after checking the right direction again
wet glass bottles.
2.wet cup body sets a ring, if you Install the missing equipment, it can cause
leak.
Oxygen odor| Early use, series of tubes or other plastic will emit odor, is a
normal phenomenon.| This odor is normal smell emitted by the sllicone tube,
which has been detected by non toxic, and with the use of the machine, the
smell will gradually disappear.
Working Principle
Warranty Card
Dear user:
Thank you for purchasing this product, for the future use of this product, you
will enjoy the company to provide you with high quality service, in order to
use the product better, please be sure to carefully read the “warranties”
before your use.
Purchase: year month day
User Name| | Sex|
---|---|---|---
Age| | Contact Telephone|
Mobile Phone| | Zip|
Contact
Address|
Product
Model| | Item No|
Sales De- partment| | Seller
Phone|
Notes:
Purchase: year month day
User Name| | Sex|
---|---|---|---
Age| | Contact Telephone|
Mobile Phone| | Zip|
Contact Address|
Product Model| | Item No|
Sales De- partment| | Seller Phone|
Notes:
Warranty Issues
- Warranty: main engine with one year warranty.
- If you buy our machine, you can enjoy the whole year warranty provided by the company’s policy.
- You can register information via the internet or by mail, for warranty.
- If the items listed below, based on the cost of fees and subject to close for repair.
- out of warranty period of the product;
- failure to use the product manual and product damage.
- Under one of the following situations,Not within the warranty service.
- unauthorized alteration warranty certificate, serial number and product labels;
- damaged products caused by unauthorized hardware changes (items missing, variation, etc);
- due to damage caused by external products;
- due to force majeure (earthquake, fire, flood, war and other disasters) product damage;
- Unauthorized disassemble products;
- deliberate destruction caused by human fault products;
- The failure to require the installation and use instructions damage caused by the company’s products;
Certificate
Production Date:………..
Quality Inspector:………..
Version Number:1.1
Part No:00.04.04-00605-02
Serial No………..
Cut Ties Description
Before using it for the first time, please follow the steps to cut cable ties.
- The arrow points to tie for transport.
- Use pliers to cut fixed ties.
- Ties must be drawn out.
- Two fixed ties can be used after being extracted.
Part No. 428-00503-000E
Address:R1011,XuesongRoad, High and New Tech,
Henan Xiaotaiyang Trading Co., Ltd
Zhengzhou City, Henan Province, China
Tel: 86 15838316518
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>