COXTOD COX-015A Oxygen Concentrator Installation Guide

June 13, 2024
COXTOD

Oxygen Concentrator
Operation Guide
COX-015A Oxygen Concentrator

COX-015A Oxygen Concentrator

Dear users,
The instructions introduce the function characteristics of this product, operation steps, notes and maintenance in d- etail.
In order to ensure that you can use the product more effec- tively, please read this manual carefully before use and k- eep it safe after reading.
Without permission, cannot take apart products in person , otherwise, you will lose the warranty.
Be careful, the company reserves the rights to update pro-ducts and technology. Some illustrations in the specifica-tion you see in the product may be different, received in -kind prevail.
Thank you for purchasing eur products, wish you use happily.
Without reading this manual, please don’t operate the pro- duct. If you have any questions on the understanding of t-his manual, please contact the seller or after-sales techni- cal personnel, don’t take action to operate the product, or it may result in serious personal injury or property damage.

Note

Safety Precautions
To prevent blackouts or household oxygen bar may break down, someone who are urgently needed oxygen must be configured with a much-needed backup support to other devices (such as: oxygen cylinder, oxygen bags, etc.), it is not considered for the life of the equipment or the use of the co- ntinuation of life.
Oxygen may cause combustion, no smoking when operating the oxygen bar When in a heat environment, sparks and open flames and other factors, do
not use household oxygen bar.
There is high-voltage in household oxygen bar, please do not disassemble.
All parts of the product, after rigorous testing, safety and reliability, so do
not use this product with other accessories made by other manufactures ot- herwise it will affect the performance.
Moving household oxygen bar by the cord or hose is prohibited.
This product with rated voltage of  220V,D110V, please use secure socket P qualified.
To prevent accidents, do not let children operate the oxygen bar. When b- reathing oxygen, not let the hose around the neck. When the elderly using the oxygen, a guardian must beside him.
Houschold oxygen bar works as a direct separation of oxygen from air, w- hich is used for breathing, so do not use in smoke, toxic and harmful gases environments.
Cautions:
Before the first use, please roll household oxygen bar, then cut off the bo- ttom of the transport fixed ties, see “Cut ties description”.
When this product is working, there will be intermittent exhaust sound, which is a normal phenomenon.
When add water to wet cup, do not exceed the maximum water level. Wh- en handling household oxygen bar, need to pour out the water in wet cup, so as not to cause backflow.
Please confirm whether the oxygen outlet, the air intake vents behind ox- ygen bar is blocked, in order to avoid downtime caused by high temperature.
This product only applies to household oxygenating, cannot be used as medical treatment.

Product Features

Product Introduction
This product uses the air as raw material. ACD 220V01110V power as power source. uses agood original zeolite by French and the air compressor 5000 hours lifespan,  Through advanced pressure swing adsorption separation in room temperature, extraction of high-purity oxygen by air, stable oxygen, safe and reliable, this method is called pure physical methods. ( Refers to working principle on p- age 12) .
Functional characteristics
Intelligent Control:
IMD beautiful large color panel, easy to operate, large color LED screen, cl- ear display, timer operation function and with infrared remote control, let it be easier and more convenient.
Anion:
This machine is equipped with ion function, and a “negative” button; the neg ative ion system can work alone , you can also work simultaneously with the oxygen system;Anion generatorAir vents located in the machine, the exhaus t vents discharged into the surrounding space of the machine when working.
Multi-layer filter, self-easy to replace:
The oxygen system of this product has coarse dust filter, fine dust filter and three bacterial filtration treatment for the input air respectively, finally, the oxygen is fresh and clean after filtering , and the two front layers filter can be replaced without disassembing, the user operate it comfortably.
Using environment
Temperature: 5-35 Relative humidity: <80%
Range of the atmospheric pressure: 0.086 MPa -0.106 MPa
When the temperature is higher or lower, do not use oxygen bar.
Technical parameters
Product name: household Oxygen Bar
Model: MAFO15A MAFO15AW
MAFO1SBW MAFO15B)
Scope of application: use as household oxygenating, not use for medical treatment
PSA methods: PSA
The input power: 115Ww
Rated voltage: AC 220 v, 50 H2 AC 110V, 50H
Current rating: O.5A
Air output: 1~6L/min
Output pressure: <100kpa
Negative oxygen ion: ≥ 6 million particles/ cm’
Noise: about 48dB
Product size: 302 168 325mm
Net weight: 5.2kg
Electrical categories: ]] Execution standard: GB4706.1-2005 Q/MAF 01-2017
Functional difference showed in the following table

Model MAF015A MAF015AW MAF015BW MAF015BJ
Oxygen concentration 30%–90% 30Von-90% 30Vog-90% 30%~90%
Remote control function Yes Yes Yes Yes
Spray function No Yes Yes Yes
Cumulative function Yes Yes Yes Yes

Installation and Operation

Opening instructions
Oxygen packing, please check the items in the box whether they complete or in tact according to the manual attachment list. Otherwise, please contact reta- iler or manufacturer.
Appearance diagram:COXTOD COX 015A Oxygen Concentrator -
Diagram Opening instructionsCOXTOD COX 015A
Oxygen Concentrator - Diagram 1

Power operation and components using
Wet cup (add water): Use left hand to hold wet cup, use right-hand to grip and rotate wet cup coun- terclockwise, lid open after the rotation in place, adding moderate amount of pure water, then close the lid and turn clockwise rotation in place.
Use of wet cup;COXTOD COX 015A Oxygen Concentrator -
Oparation Note: “The machine connected to the outlet of which ends with the wet cup white tube”
Put one end of the conduit to the wet cup inlet port B (with the inlet conduit, as difference) A is inserted into the other end of the conduit connected to the ox- ygen outlet of household oxygen bar, and finally the end of the oxygen duct p- lug to the integrated water heater outlet E.
When the water level inside the wet cup exceeds the maximum water level D, please promptly drain the water to avoid water back into the oxygen tube.
Connect the power cord, power on
Put the tail end of the power cord into the power cord socket household oxyg- en bar, and the other end connected to the indoor outlet, after power, the power switch is turned on, after the first power, microcomputer will automatically start the self-test all the bright lights of a display about 2 seconds , colleagues buzzer will sound prompt, after the self-test, automatically restore the standby mode and displays the default time “015”, “power jack” and “power switch” position, see section appearance of page four.
Power on: ON/OFF button
In standby mode, press the “ON / OFF” to wake up the machine and start wo- rking, and “oxygen” light will be lit, the default length of 15 minutes, turn off the machine by complex back to standby.
Time
Press “+, -” button to adjust the time of work time, after finish setting, press t- he “On / Off” button, the oxygen machine starts to work. (after the setup is co- mpleted, wait three seconds, the oxygen machine will automatically start wo- rking)Click the “timing” until showing the length of time.After finish working , the display window will return to standby mode and waitsfor the user to use:
If you do not use for more than ten minutes (temperament cooling system is ru- nning for about five minutes), it will enter power-savingsleep state (anion is closed ), then “Power” will flash to alert the user who can press the power swi tch back to the off state.
Anion
According to users’ needs, you can open anion function, click “anion” to open, and display “anion” light will be lit (see screen instructions on page five), pre- ss twice means close.
Remote control useCOXTOD COX 015A Oxygen Concentrator -
remote With a dedicated remote control, this product gets the remote control align- ment infrared receiver hole of oxygen machine panel.
When you find the remote control operation insensitive and cannot operate, you must check the remote control battery whether it fully charged first; re- mote control can’t be too far from the host computer, otherwise it will lead to the remote control operation insensitive.
Routine maintenance
The oxygen machine has smooth appearance, glossy, please prevent the sharp scratch it.
Please turn off the oxygen machine after finishing the timer and the air s- upply, and unplug the power in time.
 The cotton filters on the host side change in time, if the cotton filters we- re blocked by the dirty stuff, it will have an effect on oxygen.
Attention:
Please don’t take apart the machine by yourself, avoid unnecessary dam- age inside the machine, before cleaning and maintaining, oxygen machine must be cut off the power.
Handle of long idle
Remove the wet cup, drain the water out of the cup and replace host comp- uter after air-dry.
Starting up, let the oxygen machine work for thirty minutes, then wait for it to cool by natural.
Cutoff the power, replace the oxygen machine into the box.
Remote control can’t install battery while sealing, in order to prevent the battery leakage to damage the remote control.
Pls wrap and seal the main engine with plastic bags to prevent air humidity cause the machine performance degradation.
Parts maintenance
The maintenance of wet cup:
In order to ensure the cleaning of the wet cup, the injection should be pu- te water or boiled water, and try to replace every day, we suggest users c- leaning the wet cup once a week
Cotton filters and filter maintenance:
The main function of the filter is filter and adsorption the dust and im- tp!purity, it will form a blockage in turn to affect the intake of oxygen machine for a long time.
It will become intake block for a long time, thereby, have an effect on the oxygen machine; generally, replaced once a quarter, if it has much dust, recommend replacing every two months.

Problem Investigation Trouble Shooting

Symptom Possible Cause Solution

Household oxygen bar cannot operate properly, the power indicator light is not bright.| The power line is not conne- cted to a power outlet.| Check whether the socket outlet connection is normal.
Power supply socket without electricity.| Replace the electric socket.
Overload protection burning fuse| Open the insurance and replace the fuse.
Power cord is not for good in the household oxygen bar or power cord bad.| Unplug reinsert the fuselage outlet or replace a power supply cord.
The screen display normal, but the oxy- gen bar does not have normal operation soon.| Household oxygen bar over- heating protection.| Make sure the place has been away from household oxygen bar curtains, bake warm m-achines, heaters and fireplaces, and confirm household oxygen bar and walls or other o-bjects around the retention gap of at least 20 cm.
Household oxygen bar coin- puter froze plate.| Turn off the machine, wait five minutes to restart.
The compressor function b- reakdown.| Contact household oxygen bar retailer or manufacturers.
Full screen flash, while alarm.| Internal hardware damage| Returned to the manufacturer or dealer for repair.
Big Noise| Ties are not cut, the machine did not put a smooth.| Cut ties, put the machine steady.
The screen display normal and hear normal operation sound but no anoin o-xygen output.| Intake window cotton filters is dirty, cause block.| Household oxygen bar internal malfunction.
Cut off the power switch, replace window air intake fiHer cotton.| Contact the household seller or manufacturers.
Press to adjust the time when the tra- nsfer is invalid.| Sleep tone when keys are lo- cked, inoperable.| Press the “On / or button to wake, the key to adjust the time and then tune.
Symptom| Possible Cause| Solution
---|---|---
The oxygen machine emits pool bared s- ound six-minute int- ervals.| The machine emits exhaust sound.| If the machine emits poof bared sound reg- ularly is a normal phenomenon, discharge the sound of nitrogen.
Water coming out of the mouth of o- xygen.| Adding too much water in the wet cup ( exceed the highest water level ) . airflow will push oxygen tube blisters.| The water in the wet cup have reduced to the highest water level.
Difference temperature , ca- use the humidified oxygen in the wall that moisture will c- ondense water out of cold.| Pour the water out of the wet cup, starting up, after fifteen minutes ,waiting the droplets are dried in the oxygen tube, then adding water into the wet cup.
the machine is op- erating normally – after starting up, but have a narrow minded.| Flow value is too small.| Turn up flow
Wet cup Is not installed correctly cause leak| 1.wet cup cover is not fit in place, unscrew the lid anticlockwise, after checking the right direction again wet glass bottles.
2.wet cup body sets a ring, if you Install the missing equipment, it can cause leak.
Oxygen odor| Early use, series of tubes or other plastic will emit odor, is a normal phenomenon.| This odor is normal smell emitted by the sllicone tube, which has been detected by non toxic, and with the use of the machine, the smell will gradually disappear.

Working Principle

COXTOD COX 015A Oxygen Concentrator - remote 1

Warranty Card

Dear user:
Thank you for purchasing this product, for the future use of this product, you will enjoy the company to provide you with high quality service, in order to use the product better, please be sure to carefully read the “warranties” before your use.
Purchase: year month day

User Name| | Sex|
---|---|---|---
Age| | Contact Telephone|
Mobile Phone| | Zip|
Contact
Address|
Product
Model| | Item No|
Sales De- partment| | Seller
Phone|
Notes:

Purchase: year month day

User Name| | Sex|
---|---|---|---
Age| | Contact Telephone|
Mobile Phone| | Zip|
Contact Address|
Product Model| | Item No|
Sales De- partment| | Seller Phone|

Notes:

Warranty Issues

  1. Warranty: main engine with one year warranty.
  2. If you buy our machine, you can enjoy the whole year warranty provided by the company’s policy.
  3. You can register information via the internet or by mail, for warranty.
  • If the items listed below, based on the cost of fees and subject to close for repair.
  1. out of warranty period of the product;
  2.  failure to use the product manual and product damage.
  • Under one of the following situations,Not within the warranty service.
  1. unauthorized alteration warranty certificate, serial number and product labels;
  2. damaged products caused by unauthorized hardware changes (items missing, variation, etc);
  3. due to damage caused by external products;
  4. due to force majeure (earthquake, fire, flood, war and other disasters) product damage;
  5. Unauthorized disassemble products;
  6. deliberate destruction caused by human fault products;
  7. The failure to require the installation and use instructions damage caused by the company’s products;

Certificate
Production Date:………..
Quality Inspector:………..
Version Number:1.1
Part No:00.04.04-00605-02
Serial No………..

Cut Ties Description

Before using it for the first time, please follow the steps to cut cable ties.

  1. The arrow points to tie for transport.
  2. Use pliers to cut fixed ties.COXTOD COX 015A Oxygen Concentrator - Description
  3. Ties must be drawn out.
  4. Two fixed ties can be used after being extracted.COXTOD COX 015A Oxygen Concentrator - Description 21

Part No. 428-00503-000E
Address:R1011,XuesongRoad, High and New Tech,
Henan Xiaotaiyang Trading Co., Ltd
Zhengzhou City, Henan Province, China
Tel: 86 15838316518

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals