COXTOD MAF005 Oxygen Concentrator Instruction Manual

June 13, 2024
COXTOD

COXTOD MAF005 Oxygen Concentrator

Product Information

  • Product Name: Household Oxygen Bar
  • Model: [Model Number]
  • Air Output: [Air Output]
  • PSA Methods: Pressure Swing Adsorption (PSA)
  • Input Power: 115W
  • Rated Voltage: AC 220V, 50Hz
  • Current Rating: 0.5A
  • Oxygen Concentration: 30-90% (adjustable)
  • Output Pressure: [Output Pressure]

Product Usage Instructions

  1. Before the first use, unroll the household oxygen bar and cut off the bottom of the transport fixed ties.
  2. Ensure that the oxygen outlet and the air intake vents behind the oxygen bar are not blocked to prevent downtime caused by high temperatures.
  3. When adding water to the wet cup, do not exceed the maximum water level. When handling the household oxygen bar, pour out the water in the wet cup to prevent backflow.
  4. This product is only intended for household oxygenating and should not be used for medical treatment.

Safety Precautions

  • To prevent blackouts or a breakdown of the household oxygen bar, it is recommended to have backup support to other devices (such as oxygen cylinders or oxygen bags) when an urgent oxygen supply is needed.
  • The equipment’s lifespan or continuation of life is not considered. Configuring backup support is essential for emergency situations.

Product Features

  • Uses air as raw material and AC220V power as the power source.
  • Utilizes advanced pressure swing adsorption separation at room temperature to extract high-purity oxygen from the air.
  • Stable oxygen output, safe, and reliable.
  • Equipped with IMD’s beautiful large color panel for easy operation.
  • Features a large color LED screen for clear display.
  • Includes a timer operation function and an infrared remote control for convenience.
  • Equipped with an anion function that can work alone or simultaneously with the oxygen system.
  • Multi-layer filter system for fresh and clean oxygen output.
  • Easy to replace filters, including coarse dust filter, fine dust filter, and three bacterial filtration treatments for input air.
  • Suitable for use in environments with a temperature range of 5-35°C and relative humidity up to 80%.

Safety Precautions

  • To prevent blackouts or household oxygen bars may breaking down, someone who urgently needs oxygen must be configured with much-needed backup support to other devices (such as oxygen cylinder, oxygen bags, etc.), it is not considered for the life of the equipment or the use of the continuation of life.

  • Oxygen may cause combustion, so no smoking when operating the oxygen bar When in a heated environment, sparks open flames and other factors, do not use a household oxygen bar.

  • There is a high voltage in the household oxygen bar, please do not disassemble it.

  • All parts of the product, after rigorous testing, safety, and reliability, so do not use this product with other accessories made by other manufacturers otherwise it will affect the performance.

  • Moving the household oxygen bar by the cord or hose is prohibited.
    This product with rated voltage of 220V, please use a secure socket qualified.

  • To prevent accidents, do not let children operate the oxygen bar. When breathing oxygen, do not let the hose around the neck. When the elderly using oxygen, a guardian must be beside him.

  • A household oxygen bar works as a direct separation of oxygen from the air, which is used for breathing, so do not use it in smoke, toxic, and harmful gas environments.

Cautions

  • Before the first use, please roll the household oxygen bar, then cut off the bottom of the transport fixed ties, see “Cut ties description”.

  • When this product is working, there will be intermittent exhaust sound, which is a normal phenomenon.

  • When adding water to the wet cup, do not exceed the maximum water level. When handling household oxygen bars, need to pour out the water in a wet cup, so as not to cause backflow.
    Please confirm whether the oxygen outlet and the air intake vents behind the oxygen bar are blocked, in order to avoid downtime caused by high temperature.

  • This product only applies to household oxygenating, and cannot be used as medical treatment.

Product Features

Product Introduction
This product uses the air as raw material, AC220V power as a power source uses a good original zeolite by French and the air compressor Through advanced pressure swing adsorption separation in room temperature, extraction of high- purity oxygen by air, stable oxygen, safe and reliable, this method is called pure physical methods. (Refers to the working principle on).

Functional characteristics

Intelligent Control
IMD beautiful large color panel, easy to operate, large color LED screen, cl- ear display, timer operation function, and infrared remote control, making it easier and more convenient.

Anion
This machine is equipped with an ion function, and a “negative” button; the negative ion system can work alone, but you can also work simultaneously with the oxygen system; Anion generatorAir vents located in the machine, the exhaust vents discharged into the surrounding space of the machine when working.

Multi-layer filter, self-easy to replace:
The oxygen system of this product have a coarse dust filter, fine dust filter, and three bacterial filtration treatment for the input air respectively, finally, the oxygen is fresh and clean when output , and the front floor filter can be replaced without disassembling, the user operates it comfortably.

Using environment

  • Temperature: 5~35℃
  • Relative humidity :≤80%
  • Range of the atmospheric pressure: 0.086 MPa -0.106 MPa
  • When the temperature is higher or lower, do not use an oxygen bar.

Technical parameters

  • Product name : household Oxygen Bar
  • Scope of application: use as household oxygenating, not used for medical treatment
  • Model:
  • Air output:
  • PSA methods: PSA
  • The input power: 115w
  • Rated voltage: AC 220 v, 50 Hz
  • Current rating: 0.5 A
  • Oxygen concentration: 3 0~9 0 % (adjustable)
  • Output pressure: <100kpa
  • Negative oxygen ion: ≥ 6 million particles/ cm ³
  • Noise: about 48db
  • Product size: 302 168 325 mm
  • Net weight : 5.2kg
  • Electrical categories:
  • Execution standard: GB4706.1-2005
  • Execution standard: CE Certificate

Opening instructions
Oxygen packing, please check the items in the box whether it complete or in tact according to the manual attachment list. Otherwise, please contact the retailer or manufacturer.

Appearance diagram

COXTOD-MAF005-Oxygen-Concentrator-FIG-1

Screen shows

COXTOD-MAF005-Oxygen-Concentrator-FIG-2

Power operation and components using

Water cup (add water):
The left and right index fingers were inserted into a crescent above the vacancy wet cup, press and hold the remaining fingers around the body, index finger pressed under the wet cup, and then pull out, you can remove the wet cup, un-plug the humidifier on the back of the cup silicon capsules adding stone trench Officials pure water or boiled water, added water cannot exceed the maximum tire indicator line, plug silicon capsule well, and then connect the -power cord into the fuselage, power on.

Connect the power cord, power on
Put the tail end of the power cord into the power cord socket household oxygen bar, and the other end connected to the indoor outlet, after power, the power switch is turned on, after the first power, the microcomputer will automatically start the self-test all the bright lights of a display about 2 seconds (including the “failure” indicator), colleagues buzzer will sound prompt, after the self-test, automatically restore the standby mode and displays the default time “015”, “power jack” and “power switch” position, see section appearance of page four.

Power on: ON/OFF button
In standby mode, press the “ON / OFF” to wake up the machine and start working, and the “oxygen” light will be lit, the default length of 15 minutes, turn off the machine by complex back to standby.

Timing
Click the “timing” until it shows the length of time.
After finishes working, the display window will return to standby mode and wait for the user to use it: If you do not use it for more than ten minutes (tempera-ment cooling system is running for about five minutes), will enter a power-sa-ving sleep state (Note: the premise is not open anion state ), then “Power” w-ill flash to alert the user who can press the power switch back to the off state (power switch location, see appearance diagram on page four), you need to continue to use, press the “ON / OFF” button to start the machine, return to standby mode and waits for the user to use.

Anion
According to users’ needs, you can open the anion function, click “anion” to open, and display the “anion” light will be lit (see screen instructions on page five), p-ress twice means close.

Transfer oxygen
According to users’ needs, you can choose different oxygen concentrations, tap tune oxygen can get a good set of different gears, the display will also sh-ow the corresponding oxygen flow.

Catchment use (sold separately)

COXTOD-MAF005-Oxygen-Concentrator-FIG-8

Put one end of the first conduit to the sump plug inlet port B (with the inlet conduit, as difference) A is inserted into the other end connected to the oxygen outlet household oxygen bar, and finally the end of the oxygen duct plug to the integrated water heater outlet E.

When the water level inside the catchment exceeds the maximum water lev-el D, please promptly drain the water to avoid water back into the oxygen tube.

Remote control use

  • With a dedicated remote control, this product gets the remote control alignment infrared receiver hole of the oxygen machine panel.
  • When you find the remote control operation insensitive and cannot operate, you must check whether the remote control battery whether it fully charged first; re-mote control can’t be too far from the host computer,  otherwise, it will lead to the remote control operation being insensitive.

Maintenance

Routine maintenance

  • The oxygen machine has a smooth appearance, glossy, please prevent a sharp scratch it.
  • Please turn off the oxygen machine after finishing the timer and the air supply, and unplug the power in time.
  • The cotton filters on the host side change in time, if the cotton filters are blocked by the dirty stuff, it will have an effect on oxygen.

Attention:   Please don’t take apart the machine by yourself, to avoid unnecessary damage inside the machine, before cleaning and maintaining, the oxygen machine must be cut off the power.

Handle of long idle

  • Remove the wet cup, drain the water out of the cup, and replace the host computer after air-drying.
  • Starting up, let the oxygen machine work for thirty minutes, then wait for it to cool naturally.
  • Cut off the power, and replace the oxygen machine in the box.
  • The remote control can’t install a battery while sealing, in order to prevent the battery leakage from damaging the remote control.
  • Pls wrap and seal the main engine with plastic bags to prevent air humidity cause the machine performance degradation.

Parts Maintenance

  • The maintenance of wet cup:
  • In order to ensure the cleaning of the wet cup, the injection should be pure water or boiled water, and should be replaced every day, we suggest users clean the wet cup once a week
  • Air filter maintenance:
  • The main function of the air filter is to filter and adsorb the dust and im-purity, For a long time will form a blockage in turn affects the intake of oxygen machine oxygen effect.
  • It will become an intake block for a long time, thereby, having an effect on the oxygen machine; generally, replaced once a quarter, if it has much dust, recommended to be replaced every two months.

Problem Investigation and Trouble Shooting

Symptom Possible Cause Solution

The household oxygen bar cannot operate properly, the power indicator light is not bright.

| The power line is not connected to a power outlet.| Check whether the socket outlet connection is normal.
Power supply socket without

electricity.

| Replace the electric socket.
Overload protection burning fuse| Open the insurance and replace the fuse.
The power cord is not for good in the household oxygen bar or the power cord is bad.| Unplug and reinsert the fuselage outlet or replace a power supply cord.

The screen displays normal, but the oxygen bar does not have normal operation.

|

Household oxygen bar overheating protection.

| Make sure the place has been away from household oxygen bar curtains, bake warm machines, heaters, and fireplaces, and confirm household oxygen bar and walls or other o-objects around the retention gap of at least 20 cm.
Household oxygen bar com-

puter froze the plate.

| Turn off the machine, wait five minutes to

restart.

The compressor function b- reakdown.| Contact household oxygen bar retailers or m- manufacturers.
Full-screen flash,

while alarming.

| Internal hardware damage| Returned to the manufacturer or dealer for

repair.

Big Noise| Ties are not cut, and the machine did not put a smooth.| Cut ties, and put the machine steady.

The screen displays normal and hears normal operation sound but no anion oxygen output.

|

Intake window cotton filters are dirty, causing the block.

|

Household oxygen bar internal malfunction.

Cut off the power switch, r- replace the window air intake filter cotton.|

Contact the household seller or manufacturers.

Press to adjust the time when the transfer is invalid.|

Sleep tone when keys are locked, inoperable.

| Press the “On / Off” button to wake, the key to adjust the time, and then tune.
Symptom| Possible Cause| Solution
---|---|---

The household oxygen bar cannot operate properly, the power indicator light is not bright.

| The power line is not connected to a power outlet.| Check whether the socket outlet connection is normal.
Power supply socket without

electricity.

| Replace the electric socket.
Overload protection burning fuse| Open the insurance and replace the fuse.
The power cord is not for good in the household oxygen bar or the power cord is bad.| Unplug and reinsert the fuselage outlet or replace a power supply cord.

The screen displays normal, but the oxygen bar does not have normal operation.

|

Household oxygen bar over-heating protection.

| Make sure the place has been away from household oxygen bar curtains, bake warm machines, heaters, and fireplaces, and confirm household oxygen bar and walls or other objects around the retention gap of at least 20 cm.
Household oxygen bar com-

puter froze the plate.

| Turn off the machine, wait five minutes to

restart.

The compressor function b- reakdown.| Contact household oxygen bar retailers or m- manufacturers.
Full-screen flash,

while alarming.

| Internal hardware damage| Returned to the manufacturer or dealer for

repair.

Big Noise| Ties are not cut, the machine did not put a smooth.| Cut ties, and put the machine steady.

The screen displays normal and hears normal operation sound but no anion oxygen output.

|

Intake window cotton filters are dirty, causing the block.

|

Household oxygen bar internal malfunction.

Cut off the power switch, r- place the window air intake filter cotton.|

Contact the household seller or manufacturers.

Press to adjust the time when the transfer is invalid.|

Sleep tone when keys are locked, inoperable.

| Press the “On / Off” button to wake, the key to adjust the time, and then tune.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

COXTOD User Manuals

Related Manuals