Shelly The most innovative Wi-Fi combustible gas sensor User Guide
- June 7, 2024
- Shelly
Table of Contents
- Shelly The most innovative Wi-Fi combustible gas sensor User Guide
- User guide
- Specification
- Wi-Fi LED states
- Installation Instructions
- Initial Inclusion
- Factory Reset
- Introduction to Shelly®
- Control your home with your voice
- SHELLY® CLOUD MOBILE APPLICATION
- The Shelly Cloud mobile application
- Registration
- Forgotten Password
- Device Inclusion
- Step 2
- Step 3
- Step 4:
- Step 5:
- Step 6:
- Shelly devices settings
- Internet/Security
- Settings
- Device Information
- Edit Device
- THE EMBEDDED WEB INTERFACE
- Step 3
- General – Home Page
- Internet/Security
- Settings
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Shelly The most innovative Wi-Fi combustible gas sensor User Guide
User guide
Shelly® Gas by Allterco Robotics is intended to be placed, where combustible
gas(LPG or natural) is used, in order to be aware in the case of gas leakages
in the room/area.
Shelly Gas also provides a sound alarm. Shelly Gas is powered directly from
the grid. Shelly may work as a standalone device or as an accessory to a home
automation
controller.
Specification
Power supply: 110-230V ±10% 50/60Hz AC Complies with EU standards:
- RE Directive 2014/53/EU
- LVD 2014/35/EU
- EMC 2004/108/WE
- RoHS2 2011/65/UE
Gas types detected: LPG, natural Working temperature: 0° ÷ 40 °C Radio signal power: 1mW Radio protocol: WiFi 802.11
Frequency: 2400 – 2500 MHz; Operational range:
-
up to 50 m outdoors
-
up to 30 m indoors
Dimensions (HxWxL): -
Without plug – 90x90x38 mm
-
With plug – 90x90x60 mm Electrical consumption: < 1 W Alarm Sound: 70dB (at 1m)
Wi-Fi LED states
STA Mode
(with Cloud connection)| Static
---|---
STA Mode
(without Cloud connection)| Static, blink each 5 sec
STA Mode
(without Interner connection)| Static, blink each 3 sec
AP Mode| Blink each 1 sec
Sensor warm up starts,
upon power on| 2 times short sound
(twice per second)
Success of sensor
warming up| One long sound
(once per second)
Sensor fault| Long sound (once per
second) until sensor is
recovered from fault
Device self test| 3 times short sound
(twice per second)
Mild gas leak| The device makes a long
sound (once per second),
until gas leakage
is not present, or until
the device enters “Heavy
leakage of gas” mode.
Heavy gas leak| The device makes a long
sound alarm (5 seconds,
with 1 second off), until
gas leakage is not present.
Success of sensor
self test| One time long sound
(once per second)
Installation Instructions
!CAUTION – Before beginning the installation please read the accompanying
documentation carefully and completely. Failure to follow recommended
procedures could
lead to malfunction, danger to your life or violation of the law. Allterco
Robotics is not responsible for any loss or damage in case of incorrect
installation or operation of
this device.
!CAUTION – Use the Device only with power grid which complies with all
applicable regulations. Short circuit in the power grid may damage it.
!CAUTION – Do not allow children to play with the device, especially with the
Power Button. Keep the devices for remote control of Shelly (mobile phones,
tablets, PCs) away from children.
Initial Inclusion
Place Shelly into the power socket, in the room where you want to use it. For
LPG gas detection the unit is best to be placed 15-30cm above the floor and
for natural gases the
unit is best to be placed 2-3m above the floor. The device will make a self
test, and in the first 3 minutes the LED ring should turn in a sequence:
green->orange->red. After the self test is finished, the LED ring should turn
green and the WiFi LED should be blinking, once per second. This means that
the device is calibrated and is in AP mode.
Factory Reset
You can return your Shelly Gas to its Factory Settings by pressing and holding
the reset button for 10 seconds. Upon successful factory reset the WiFi LED
will blink once
per second.
Introduction to Shelly®
Shelly® is a family of innovative devices, which allow remote control of
electric appliances through mobile phone, PC or home automation system.
Shelly® uses WiFi to connect to the devices controlling it (mobile phones,
tablets etc.). They can be in the same WiFi network or they can use remote
access (through the Internet – Shelly Cloud).
Shelly® has an integrated web server, through which the User may adjust,
control and monitor the Device. An API can be provided by the Manufacturer.
The User can register
and access the Shelly Cloud, using either Android or iOS mobile applications,
or any internet browser and the web site: https://my.shelly.cloud/.
Control your home with your voice
All Shelly devices are compatible with Amazons’ Alexa and Googles’ assistant.
Please see our step-by-step guides on:
https://shelly.cloud/compatibility/Alexa
https://shelly.cloud/compatibility/Assistant
SHELLY® CLOUD MOBILE APPLICATION
The Shelly Cloud mobile application
all Shelly® devices from anywhere in the world. The only thing you need is
connection to the Internet and our mobile application, installed on your
smartphone or tablet.
To install the application please visit Google Play or App Store.
Registration
The first time you open the Shelly Cloud mobile app, you have to create an account which can manage all your Shelly® devices.
Forgotten Password
In case you forget or lose your password, just enter the e-mail address you
have used in your registration. You will then receive instructions on how to
change your password.
WARNING! Be careful when you type your e-mail address during the
registration, as it will be used in case you forgot your password.
After registering, create your first room (or rooms), where you are going to
add and use your Shelly devices. Shelly Cloud allows easy control and
monitoring using a mobile
phone, tablet or PC.
Device Inclusion
To add a new Shelly device, connect it to the power grid following the
Installation Instructions included with the Device.
Step 1
Place your Shelly into the power socket, in the room where you want to use it.
The WiFi LED should be blinking, once per second.
WARNING: If the WiFi LED is not blinking once per second, press and hold
the reset button for at least 10 seconds. The WiFi LED should be blinking,
once per second. If not, please repeat or contact our customer support at:
support@ shelly. cloud
Step 2
Choose “Add Device”. In order to add more devices later, use the Menu at the
top right corner of the main screen and click “Add Device”.
Type the name and password for the WiFi network, to which you want to add
Shelly.
Step 3
If using iOS: you will see the following screen(left): On your iOS device open
Settings > WiFi and connect to the WiFi network created by Shelly, e.g.
ShellySmoke-35FA58.
If using Android: your phone will automatically scan(right) and include all
new Shelly devices in the WiFi network, that you defined.
Upon successful Device Inclusion to the WiFi network you will see the
following pop-up:
Step 4:
Approximately 30 seconds after discovery of any new devices оn the local WiFi
network, а list will be displayed by default in the “Discovered Devices” room.
Step 5:
Select Discovered Devices and choose the Shelly device you want to include in
your account.
Step 6:
Enter a name for the Device. Choose a Room, in which the device has to be
positioned. You can choose an icon or upload a picture to make it easier to
recognize. Press
“Save Device”.
Step 7:
To enable connection to the Shelly Cloud service for remote control and
monitoring of the Device, press “yes” on
the following pop-up.
Shelly devices settings
After your Shelly device is included in the app, you can control it, change
its settings and automate the way it works.
To enter the details menu of the device, click on it’s name. From there you may control the device, as well as edit its appearance and settings.
Self Tes t
Sensor Self Test – Make a self-test of the device. To enter the details menu
of the device, click on it’s name. From there you may control the device, as
well as edit its appearance and settings.
Self Test
Sensor Self Test – Make a self-test of the device
Mute
Mute the device, when the alarm is on. You can not mute
the device, if the alarm is not triggered.
Internet/Security
WiFi Mode – Client
Allows the device to connect to an available WiFi network. After typing the
details in the respective fields, press Connect.
WiFi Client Backup
Allows the device to connect to an available WiFi network, as a secondary
(backup), if your primary WiFi network becomes unavailable. After typing the
details in the respective fields, press Set.
WiFi Mode – Acess Point
Configure Shelly to create a Wi-Fi Access point. After typing the details in
the respective fields, press Create Access Point.
Restrict Login
Restrict the web interface of Shely with a Username and Password. After typing
the details in the respective fields, press Restrict Shelly.
Settings
Volume
Define the alarm volume level of the device, when the alarm is triggered.
Possible range: 1 ~ 11.
Time Zone and Geo-location
Enable or Disable the automatic detection of Time Zone and Geo-location.
Factory Reset
Return Shelly to its factory default settings.
Device Reboot
Restart your Shelly device.
Device Information
- Device ID – Unique ID of Shelly
- Device IP – The IP of Shelly in your Wi-Fi network
Edit Device
- Device Name
- Device Room
- Device Picture
When you are done editing press Save Device.
THE EMBEDDED WEB INTERFACE
Even without the mobile app Shelly can be set and controlled through a browser
and connection of a mobile
phone or tablet.
Step 3
Type 192.168.33.1 into the address field of your browser to load the web interface of Shelly.
General – Home Page
This is the home page of the embedded web interface.
- Current alarm status
- Current PPM* count
- Connection to Cloud
- Present time
- Settings
- PPM – intensity of combustible gas in the area
Self test
Make a self-test of the device
Mute
Mute the device, when the alarm is on. You can not mute the device, if the
alarm is not triggered
Internet/Security
WiFi Mode – Client
Allows the device to connect to an available WiFi network. After typing the
details in the respective fields, press Connect.
WiFi Client Backup
Allows the device to connect to an available WiFi network, as a secondary
(backup), if your primary WiFi network becomes unavailable. After typing the
details in the respective
fields, press Set.
WiFi Mode – Acess Point
Configure Shelly to create a Wi-Fi Access point. After typing the details in
the respective fields, press Create Access Point.
Restrict Login
Restrict the web interface of Shely with a Username and Password. After typing
the details in the respective fields, press Restrict Shelly. SNTP Server You
can change the default SNTP server. Enter the address, and click Save.
Advanced – Developer Settings
Here you can change the action execution:
- Via CoAP (CoIOT)
- Via MQTT
Cloud
You can Activate/Deactivate the connection to Shelly
Cloud.
ATTENTION! To reset the device, press and hold the Button for at least 10 seconds. Upon successful factory reset, Shelly will make a lond sound.
Settings
Time Zone and Geo-location
Enable or Disable the automatic detection of Time Zone and Geo-location. If
Disabled you can define it manually.
Volume
Define the alarm volume level of the device, when the alarm is triggered.
Possible range: 1 ~ 11
Firmware Upgrade
Shows present firmware version. If a newer version is available, you can
update your Shelly by clicking Upload to install it.
Factory reset
Return Shelly to its factory settings.
Device Reboot
Reboots the device.
Device Info
Shows your device ID. In Client Mode shows also your WiFi network name and
WiFi signal strength.
Additional Features
Shelly allows control via HTTP from any other device, home automation
controller, mobile app or server. For more information about the REST control
protocol,
please visit www.shelly.cloud or send a request to developers@ shelly.cloud.
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>