PEDROLLO QET Electric Panel For Three Phase Electric Pump Instruction Manual

June 13, 2024
pedrollo

PEDROLLO-logo

PEDROLLO QET Electric Panel For Three Phase Electric Pump

PEDROLLO-QET-Electric-Panel-For-Three-Phase-Electric-Pump-
product

Product Information

Operating Instructions
The QEM QET Control Boxes for 4 Borehole Pumps are made in Italy. The control boxes are designed to ensure safe and efficient operation of the borehole pumps. The product is suitable for use in various applications, provided that the instructions and warnings outlined in this user manual are followed.

Symbols and Warnings
The user manual includes several symbols and warnings to ensure safe usage of the product:

  • DANGER: This symbol indicates a hazardous situation that may result in severe injuries or damage to goods. It is crucial to carefully follow the prescriptions when encountering this danger sign.
  • CAUTION: This symbol indicates a hazardous situation that may result in severe injuries or damage to goods. Caution is required.
  • WARNING: The instructions provided with this sign must be followed to avoid malfunction, equipment damage, and injury to personnel.

Warnings and Precautions
Before operating the QEM/QET control boxes, it is important to take note of the following warnings and precautions:

  • Always cut off the power supply before working on the electrical panel or system.
  • The electrical panel must be connected by a qualified electrician according to the electrical regulations in force.
  • Ensure the system is connected to an efficient earthing system before executing any other work.
  • After the system is connected, check the settings of the electrical panel as the electrical pump may start automatically.
  • Perform an immediate inspection upon receipt of the goods to ensure no damage occurred during transport.
  • The QEM/QET electrical panels should only be used for their intended purpose and function as specified in the design. Any other application or use is considered improper and hazardous.
  • All panel installation and maintenance operations must be performed by a specialized technician who is fully aware of the relevant safety standards.
  • Always disconnect the unit from the power supply before maintenance or cleaning.
  • If the QEM/QET control boxes are not used for prolonged periods, store them in a clean and safe location protected against atmospheric agents and the potential risk of dropping/falling.
  • In the event of a fire in the place of installation or the surrounding area, avoid using water jets and use appropriate extinguishing equipment and means (powder, foam, carbon dioxide).
  • Install the equipment far from heat sources and in a dry and sheltered location, following the stated protection rating (IP).
  • It is recommended to install a safety device to protect the panel power line in compliance with current electrical standards.

General Description (Technical Characteristics)
The technical characteristics of the QEM/QET control boxes are not provided in the extracted text. Please refer to the complete user manual for detailed information regarding the product’s technical specifications.

Installation
The installation instructions for the QEM/QET control boxes are not provided in the extracted text. Please refer to the complete user manual for detailed installation guidelines.

Luminous Indicators and Control Commands
The information about luminous indicators and control commands is not provided in the extracted text. Please refer to the complete user manual for detailed information on the luminous indicators and control commands of the QEM/QET control boxes.

Standard Circuit Diagrams
The standard circuit diagrams for the QEM and QET control boxes are not provided in the extracted text. Please refer to the complete user manual for detailed circuit diagrams.

General Conditions
The product warranty provided by Pedrollo S.p.a company is subject to the general terms of sale. To acknowledge the warranty, it is necessary to strictly follow the operating instructions in this booklet and apply the correct mechanical, hydraulic, and electro-technical practices. All products are covered by a warranty valid for 24 months, which includes the replacement or repair of defective parts due to construction defects.

OPERATING INSTRUCTIONS

SYMBOLS AND WARNINGS
The symbols below indicate hazardous situations that may arise if the prescriptions pro-vided in this use and maintenance manual are not fulfilled.

  • This warning sign is used when there is a danger of death and to indicate an hazardous situation which may result in severe injuries or damage of goods. Follow the prescriptions carefully when you see this danger sign.
  • This warning sign is used when there is a danger of death and to indicate an hazardous situation which may result in severe injuries or damage of goods. Caution is requirede.
  • The instructions provided with this sign must be followed to avoid malfunction and damage to the equipment and prevent injury to personnelratore.
  • Cut off the power supply before working on the electrical panel or on to the system.
  • The electrical panel must be connected by a qualified electrician according to the electrical regulations in force.
  • Connect to an efficient earthing system before executing any other work.
  • After the system is connected check the settings of the electrical panel since the electrical pump may start automatically.

GENERAL INFORMATION

This manual must always accompany the relevant equipment and be conserved in an accessible location for consultation by qualified technicians assigned for operation and maintenance of the system.
The installer/user is strongly recommended to read carefully all instructions and information in this manual before using the product, in order to avoid damage or improper use of the unit, which would also affect the warranty as null and void.
Before operating the equipment, carefully read the manual and follow all instructions herein. The information and instructions in this manual refer to the standard use of this product; in the event of special circumstances, functions or applications not described in this document, contact our service centre for assistance.
If technical assistance or spare parts are required, when contacting the manufacturer always specify the identification code of the model and construction number as stated on the data plate.
Our service centre is available for any requirement or clarification.
The electrical equipment supplied must be installed indoors in a well- ventilated environment, within a temperature range of -5° to +40°C.

WARNINGS
On receipt of the goods, perform an inspection immediately to ensure that the equipment has not been damaged during transport.
The QEM/QET electrical panels must be used exclusively for the purpose and function as spe-cified in design. Any other application or use is to be considered improper and therefore ha-zardous.
All QEM/QET panel installation and maintenance operations must be performed by a specialized technician who is fully aware of the relevant current safety standards.
Always disconnect the unit from the power supply before maintenance or cleaning.
If QEM/QET is not used for prolonged periods, store the product in a clean and safe location protected against atmospheric agents and the potential risk of dropping/falling.
In the event of a fire in the place of installation or the surrounding area, avoid the use of water jets and use the appropriate extinguishing equip-ment and means (powder, foam, carbon dioxide).
Install the equipment far from heat sources and in a dry and sheltered location in observance of the stated protection rating (IP). The installation of a safety device is recommended to protect the panel power line in compliance with current electrical standards.

GENERAL DESCRIPTION (TECHNICAL CHARACTERISTICS)

  • Power supply 1~50/60 Hz 230V ±10% (QEM);
  • Power supply 3~50/60 Hz 400V ±10% (QET);
  • Main Switch ON/OFF (QEM only)
  • Main Switch MANUAL/OFF/AUTOMATIC (QET only)
  • Motor overcurrent protection
  • Green led: Motor active (ON);
  • Red led: Thermal relay protection active (QET only);
  • Input for float / pressure switch (QET only);
  • Fuses with aM tripping curve (QET only);
  • Box in ABS, IP55;
  • Ambient temperature: -5/+40 °C;
  • Relative humidity 50% at 40 °C (condensate free).

INSTALLATION

Ensure that the main power supply specifications corresponds to the voltage specified on the data plate of the electrical panel and motor connected, then make the earthing connection before all other connections.

  • QEM ➞ 230V ± 10% 50Hz
  • QET ➞ 400V ± 10% 50Hz

The power line must be protected by a residual current circuit breaker. Tighten the electrical cables on the relative terminals using a suitable tool correctly sized to avoid the risk of damage to the fixing screws. Take care if using an electric screwdriver.

LUMINOUS INDICATORS AND CONTROL COMMANDS
QEM
By turning the main switch to position (1), the control box starts the pump and turns on the green led. The pump will remain in operation until the main switch is not turned in the position (0).
If an overload occurs in the water pump’s motor, the intervention of the thermal protection stops the pump and turn off the led. The intervention of the protection is showed when the thermal protection button drops out. To restore the functioning of the control box after the intervention of the protection press the button down.

QET
By turning the main switch to the MAN position, the control box starts the pump in manual mode. green led goes out indicating that the water pump is running. The pump will remain on until the main switch is not turned to the 0 position.
By turning the main switch to the AUT position, the control box activates the pump only if the contact wired to the P-P terminals is closed. The pump will remain on until the main switch is not turned to the position (0) or until P-P contact is not opened.
The amperometry relay will stop the water pump during a situation of overloading of the motor. It will turn off the green led and the red led goes out to show the tripping. To restore the operation of the control box after the intervention of the protection, turn the main switch to position (0), open the control box, and press down the RESET button.
The automatic reset of the protection can be set by pressing down the reset button and turning it ¼ turn clockwise (not recommended).

STANDARD CIRCUIT DIAGRAMS

QEM

QET

PEDROLLO QET Electric Panel For Three Phase Electric
Pump

GENERAL CONDITIONS

Warranty
The product warranty is subject to the general terms of sale of the Pedrollo S.p.a company. Acknowledgement of the warranty depends on the strict and proven fulfilled of the ope-rating instructions in this booklet and application of the correct mechanical, hydraulic and electro-technical practices.
All products are covered by a warranty valid for 24 months, which covers all construction defectsof our products and includes the replacement/repairs of defective parts
The warranty will not be deemed valid in the event of:

  • tampering with the panel (modifications without prior authorization);
  • faults due to lack of or inadequate protection and/or connection errors;
  • faults caused by exceeding data plate specifications;
  • normal wear and tear;
  • failure by installation personnel to observe the specified operating procedures;
  • accidental causes, natural disasters of any kind, such as fires, flooding, water or lightening;

The defective material must be delivered carriage paid to Pedrollo S.p.A., who reserves the right to final judgement of the cause of the said defects.
The Warranty applies exclusively to restoring the original product characteristics and does not cover material damage or physical injury.

Maintenance
QEM/QET does not require routine maintenance provided that it is used within the operating limits and in observance of the instructions in this manual.
Special maintenance or repairs must be performed exclusively by authorized service centers. In the event of repairs, only original spare parts must be used.
The manufacturer declines all liability for material damage or injury to persons or animals caused by maintenance interventions performed by unauthorized personnel or using non-original materials.

Disposal
In the event of disassembly and scrapping, strictly observe local legislation regarding pollution.
Waste disposal according to material categories is recommended.

DECLARATION OF CONFORMITY

PEDROLLO S.p.A.
Via E. Fermi, 7
37047 – San Bonifacio (VR)
hereby declares, under its sole responsibility, that the machine:
Trade mark PEDROLLO
QEM and QET series
complies with the provisions of the following EU directives and subsequent amendments:

  • 73/23/CEE
  • 93/68/CEE

in compliance with the following technical standards:
CEI 17-13/1 (EN 60439-1)
CEI 70-1 (EN 60529)
CEI 44-5 (EN 60204-1)
EN 60335-1/95
San Bonifacio, 10/07/2013

PEDROLLO S.p.A.
Via E. Fermi, 7
37047 San Bonifacio – (Verona) – Italy
Tel. +39 045 6136311 – Fax +39 045 7614663
e-mail: sales@pedrollo.comwww.pedrollo.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals