SPECIFICATION

  • WEIGHT DISPLAY: LCD, 4 1/2 Digit, 1.0” Characters
  • DISPLAY SIZE: 63″ W x 3.54″ D x 1.77″ H (270 mm x 90 mm x 45 mm)
  • PLATFORM SIZE: 2″ W x 11.8″ D x 1.97”H (310 mm x 300 mm x 50 mm)
  • POWER: 9V DC 100mA power supply or (6) AA alkaline batteries (not included)
  • TARE: 100% of full-scale capacity
  • TEMPERATURE: 40 to 105°F (5 to 40°C)
  • HUMIDITY: 25% ~ 95% RH
  • CAPACITY X DIVISION : 550lb x 0.2lb (250kg x 0.1kg)
  • KEYS: ON/OFF, NET/GROSS, UNIT, TARE

INTRODUCTION

Thank you for purchasing our Detecto Model DR550C Digital Scale.  The DR550C is equipped with a Stainless Steel platform that is easily removed for cleaning.  With the included 9V DC adapter, the scale can be used in a fixed location.

This manual will guide you through the setup and operation of your scale. Please read it thoroughly before attempting to operate this scale and keep it handy for future reference.

The affordable DR550C stainless steel platform scale from Detecto is accurate, dependable, lightweight, and portable, making it ideal for mobile clinics and home care nurses. The remote indicator has a big LCD screen that is 55mm high, units conversion, and tare. To guarantee patient safety when getting on and off the scale, the unit incorporates a slip-resistant pad. Because the DR550C runs on batteries, you can carry it anywhere you need it.

Proper Disposal

When this device reaches the end of its useful life, it must be properly disposed of.  It must not be disposed of as unsorted municipal waste.  Within the European Union, this device should be returned to the distributor from where it was purchased for proper disposal.  This is in accordance with EU Directive 2002/96/EC.  Within North America, the device should be disposed of in accordance with the local laws regarding the disposal of waste electrical and electronic equipment.

It is everyone’s responsibility to help maintain the environment and to reduce the effects of hazardous substances contained in electrical and electronic equipment on human health.  Please do your part by making certain that the device is properly disposed of.  The symbol shown to the right indicates that this device must not be disposed of in unsorted municipal waste programs.

INSTALLATION

Unpacking

Before beginning installation of your scale, make certain the instrument has been received in good condition.  When removing the scale from its packing, inspect it for signs of damage, such as exterior dents and scratches.  Keep the carton and packing material for return shipment if it should become necessary.  It is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit.

  1. Remove the scale from the shipping carton and inspect it for any signs of damage.
  2. Plug-in the supplied 9VDC power supply or install (6) AA 1.5V alkaline battery. Refer to the POWER SUPPLY or BATTERY sections of this manual for more instruction.
  3. Place the scale on a flat level surface, such as a table or bench.
  4. The scale is now ready for use.

Power Supply

To apply power to the scale using the supplied 9VDC, 100 mA power supply, insert the plug from the power supply cable into the power jack on the back of the scale and then plug power supply into the proper electrical outlet.  The scale is now ready for operation.

Battery

The scale can use (6) AA 1.5V alkaline batteries (not included).  If you wish to operate the scale from batteries, you must first obtain and install the batteries.  The batteries are contained in a cavity inside the scale. Access is via a removable door on the top cover of the scale.

Battery Installation

The DR550C Digital Scale operates with (6) “AA” batteries (Alkaline preferred).

  1. Place unit upright on a flat surface and lift platform from top of scale.
  2. Remove battery compartment door and insert batteries into compartment. Make certain to observe the correct polarity.
  3. Replace compartment door and platform cover on scale.

**Mounting the Unit**

  1. Mount bracket to wall using (2) screws that are appropriate anchors for the surface being mounted to.
  2. Lower control panel into the mounting bracket. Insert flat tip screws (included) through round holes in mounting bracket and drive the screws into existing threaded holes in the lower half of the control panel to secure control panel to bracket.

DISPLAY ANNUNCIATORS

The annunciators are turned on to indicate that the scale display is in the mode corresponding to the annunciator label or that the status indicated by the label is active.

Net

The “Net” annunciator is turned on to indicate that the displayed weight is in net mode.

Gross

The “Gross” annunciator is turned on to indicate that the displayed weight is in Gross mode.

(Minus Weight)

This annunciator is turned on when a negative (minus) weight is displayed.

lb

Red LED at the right of “lb” will be turned on to indicate the displayed weight is in pounds.

kg

Red LED at the right of “kg” will be turned on to indicate the displayed weight is in kilograms.

Lo (Low Battery)

When the batteries are near the point they need to be replaced, a low battery indicator on the display will turn on.  If the voltage drops too low for accurate weighing, the scale will automatically shut off and you will be unable to turn it back on. When the low battery indicator is displayed, the operator should replace the batteries or remove the batteries and plug the power supply into the scale and then into the proper electrical wall outlet.

KEY FUNCTIONS

ON / OFF

  1. Press and release to turn on scale.
  2. Press and release to turn the scale off.

NET / GROSS

  1. Toggle between Gross and Net.

UNIT

  1. Press to change the weighing units to the alternate units of measurement (if selected during configuration of the scale).
  2. In the Configuration mode, press to confirm the setting for each menu.

TARE

  1. Press to reset the display to zero up to 100% of the scale capacity.
  2. Press and hold for 6 seconds to enter Configuration mode.
  3. In the Configuration mode, press to select menu.

OPERATION

DO NOT operate the keypad with pointed objects (pencils, pens, etc). Damage to keypad resulting from this practice is NOT covered under warranty.

Turn the Scale On

Press the ON / OFF key to turn the scale on.  The scale will display  8888 then change to the selected weighing units.

Select the Weighing Unit

Press the UNIT key to alternate between the selected weighing units.

Weighing an Item

Place the item to be weighed on the scale platform.  Wait a moment for the scale display to stabilize, then read the weight.

To Re-Zero the Weight Display

To re-ZERO (tare) the weight display, press the TARE key and continue.  The scale will re-ZERO (tare) until the full capacity is reached.

Net / Gross Weighing

This is useful when weighing in merchandise to be weighed in a container.  To control the total weight, the value of the container may be retrieved.  This way it is possible to control to what extent the loading area of the scale is utilized.  (Gross, i.e. incl. weight of container).

Turn the Scale Off

With the scale turned on, press the ON / OFF key to turn the scale off.

CARE AND MAINTENANCE

The heart of the DR550C Digital Scale is 4 precision load cells located in the four corners of the scale base.  It will provide accurate operation indefinitely if protected against the overload of scale capacity, dropping items on a scale, or another extreme shock.

  • DO NOT submerge scale or display in water, pour or spray water directly on them.
  • DO NOT use acetone, thinner or other volatile solvents for cleaning.
  • DO NOT expose scale or display to direct sunlight or temperature extremes.
  • DO NOT place scale in front of heating/cooling vents.
  • DO clean scale and display with a damp soft cloth and mild non-abrasive detergent.
  • DO remove power before cleaning with a damp cloth.
  • DO provide clean AC power and adequate protection against lightning damage.
  • DO keep surroundings clear to provide clean and adequate air circulation.

FCC Compliance Statement

This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual, may cause interference to radio communications.  It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment.  Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference.

You may find the booklet “How to Identify and Resolve Radio TV Interference Problems” prepared by the Federal Communications Commission helpful.  It is available from the U.S. Government Printing Office, Washington, D.C. 20402. Stock No. 001-000-00315-4.

All rights reserved.  Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein.  While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein.  All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution.  For this reason the Seller is not able to guarantee the result of any procedure contained herein.  Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk.

FREQUENTLY ASKED QUESTIONS

Does this come with an adapter to plug it in?

Yes, it comes with a plug.

Is assembly required?

No, assembly is required. Just plug it in.

Is this scale sensitive to foot position or angle like regular bathroom scales?

No, it isn’t.

Does the scale number “lock” on the screen when it hits a steady weight?

No. Although it has a HOLD button, pressing it simply resets the weight to zero.

Does the display have a backlight to light it up?

No, it doesn’t have a backlight.

Can I wear shoes and be weighed or do I have to be barefoot?

It is preferred to be barefoot as wearing shoes add to your weight.

Can this balance be calibrated?

Yes.

Does it measure anything besides weight such as BMI?

No.

Is this scale waterproof or water-resistant at all?

No, it isn’t.

Does this measure fat?

No, it doesn’t measure fat.

Can the cord be detached from the base unit?

No, it can’t be.

Does mounting require holes be made in wall?

Yes.

Does this scale have an auto-off feature?

Yes, it has auto off feature.

Is Detecto weighing scale accurate?

Digital precision balance scales from DETECTO are designed for extremely accurate weighing applications and have an accuracy of 10 milligrams.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

DETECTO User Manuals

Related Manuals