Sonel CMM-60 Multimeter Software User Manual

June 13, 2024
Sonel

Sonel CMM-60 Multimeter Software

Sonel-CMM-60-Multimeter-Software-product

Product Information

The Sonel CMM-60 Multimeter Software is a computer program designed for remote readout of measurement results via Bluetooth. It allows users to connect their multimeter to a computer and view measurement data on the screen. The software is compatible with the CMM-60 multimeter.

  • Manufacturer : SONEL S.A.
  • Address : ul. Wokulskiego 11, 58-100 widnica, Poland
  • Version : 1.01
  • Date : 29.06.2023

Product Usage Instructions

Installation of the Bluetooth receiver in the PC

  1. Download the CMM-RR Driver from the SONEL website www.sonel.pl or acquire it from the Sonel DVD.
  2. Insert the CMM-RR into the computer’s USB port and open Device Manager.
  3. In the Ports menu, find the unidentified USB device. Alternate name: TI CC2540 USB CDC.
  4. Right-click on the device and select “Update driver”.
  5. Choose manual installation of the driver.
  6. Select the location of the CMM-RR Driver folder.
  7. The driver should be successfully installed.
  8. Note down the receiver port number. In the example given, it is COM2.

Pairing the multimeter with the application

  1. Select the desired device and click on it to establish a connection.
  2. After a successful connection, the current data will be displayed on the screen.

Data logging
To save a graph to the computer’s clipboard, click on “Copy Graph”.

  • File
    • Open: Opens a logger or real-time file.
    • Save: Saves a logger or real-time file.
    • Save as: Saves a logger or real-time file with a different name.
    • Export To Excel: Exports a logger or real-time file to an Excel file.
    • Print Graph: Print the graph.
  • Data
    • View Toolbar: Shows/hides the toolbar.
    • Status Bar: Shows/hides the status bar.
    • Com Port ConnectBle: Connects to the COM port.
    • Real-Time Start: Starts real-time measurement.
    • Stop Stops measurement.
    • DataLogger: Opens the data logger.
    • Graph Setting: Changes graph colors.
  • Help
    • Help: Displays the user manual.
    • About Multimeter: Displays information about the software version.

Toolbar functions

  • Rczka Tool
    • Drag the mouse with the left button pressed to move the graph.
  • Przybli zaznaczenie Tool
    • Drag the mouse with the left button pressed to zoom in on the selected area.
  • Powiksz w pionie Tool
    • Restores the default vertical zoom of the graph.
  • Szybka transformacja Fouriera FFT Tool
    • Select the data on the graph for analysis.
    • Set the filtering (none, Hamming, Hanning, Triangle, Blackman, or 4-term Blackman-Harris).

Downloading data from the multimeter
Select “DataLogger” and click “Download Multimeter DataLogger” to retrieve the data saved in logger mode from the multimeter’s memory. After downloading, a list of all recordings will be displayed in the left part of the window.

Manufacturer
The manufacturer and service provider for the device and software is SONEL S.A.

Contact Information:

  • Address: ul. Wokulskiego 11, 58-100 widnica, Poland
  • Tel : +48 74 884 10 53 (Customer Service Office)
  • Email : bok@sonel.pl
  • Website : www.sonel.pl

Installation of the Bluetooth receiver in the PC

  1. Download the CMM-RR Driver from the SONEL website www.sonel.pl or acquire it from the Sonel DVD.
  2. Insert CMM-RR into the computer’s USB port and open Device Manager.
  3. In the Ports menu find an unidentified USB device.
    • Alternate name : TI CC2540 USB CDC.
  4. Select the unidentified device and after right-clicking select Update Driver SoftwareSonel-CMM-60-Multimeter-Software-fig- \(4\)
  5. Manually search and install driver software.Sonel-CMM-60-Multimeter-Software-fig- \(6\)
  6. Select the driver software location in the CMM-RR Driver folder.Sonel-CMM-60-Multimeter-Software-fig- \(7\)
  7. The driver has been successfully installed.Sonel-CMM-60-Multimeter-Software-fig- \(8\)
  8. Check the device’s port number. In this example it is COM2.

Pairing the meter with the application

  1. Start CMM-60 Multimeter Software. MNSonel-CMM-60-Multimeter-Software-fig- \(9\)
  2. In the main menu select Com Port ► ConnectBle.Sonel-CMM-60-Multimeter-Software-fig- \(11\)
    1. Insert the COM port’s number (sec. 0 step
  3. Click the Scan button to scan for multimeters.Sonel-CMM-60-Multimeter-Software-fig- \(11\)
    • The scanning result is as above. Select the device in ① and click ② to connect.
    • Measuring data will be displayed normally after a successful connection.Sonel-CMM-60-Multimeter-Software-fig- \(12\)

Data recording

  1. In the main menu select Start ► Real Time to begin data recording.Sonel-CMM-60-Multimeter-Software-fig- \(13\)
  2. Select the Data List in the drawing area to check for the recorded data list.Sonel-CMM-60-Multimeter-Software-fig- \(14\)
  3. You can also select Summary in the drawing area to see related statistical information.Sonel-CMM-60-Multimeter-Software-fig- \(15\)
  4. Clicking the Copy Graph button exports the graph to the computer’s clipboard.Sonel-CMM-60-Multimeter-Software-fig- \(16\)

Menu functions

Sonel-CMM-60-Multimeter-Software-fig- \(17\)

  • opens multimeter logger (or real-time) file
  • saves multimeter logger (or real-time) file
  • exports multimeter logger (or real-time) data to *.xls file format
  • starts recording the real-time data
  • stops recording real-time data
  • prints the graph
  • displays the version of the software

Toolbar functions

  • Hand tool
    • Move the mouse while holding the left mouse button to move the graph.
  • Local amplifier
    • Move the mouse while pressing the left mouse button to enlarge the chosen area.
  • Vertical amplification
  • Horizontal amplification
  • Numerical display
    • Obtain the reading’s data by clicking a point in the graphics area.
  • Fits all of the graphs into the screen
  • FFT transform
    • Fast Fourier Transformation analyzer. Press the left mouse button to choose the data range that needs to be transformed.Sonel-CMM-60-Multimeter-Software-fig- \(27\)
    • Set Filter (none, Hamming, Hanning, Triangle, Blackman or 4-term Blackman-Harris).
    • Set FFT size (32, 64, 128, 256, 512, 1024, 2048).
    • Select the spectrum of the analysis (power or frequency).
    • Click Run to obtain the analysis.
    • Click Close to exit the window.

Downloading data from the meter

  1. Select DataLogger ► Download Multimeter DataLogger to download data of logger from Multimeter memory
    • After downloading, data will show in the Logger List.
    • Double-click the item on the list to show and analyze the measurement data.Sonel-CMM-60-Multimeter-Software-fig- \(28\)

Manufacturer
The manufacturer of the device and software provides all warranty and after- warranty repairs:

SONEL S.A. Wokulskiego 11 58-100 Swidnica Poland

Customer Service

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>