ansult 019929 LED Strip Light Instruction Manual
- June 4, 2024
- ansult
Table of Contents
ansult 019929 LED Strip Light
SAFETY INSTRUCTIONS
- Read these instructions carefully before installation and use, and save them for future reference.
- The product is not dimmable.
- Disconnect the power supply before installation.
- The product is only intended for indoor use in dry areas. Damp areas and outdoor environments require products with a higher protection rating.
- Never modify the product or any of its parts in any way – risk of personal injury or material damage.
- The product is intended for lights with 2-pin IEC approved G13 standard sockets.
- The product should be installed by an authorised electrician in accordance with the relevant electrical safety regulations.
ELECTRICAL SAFETY!
New installations and extensions to existing systems should always be
carried out by an authorised electrician. If you have the necessary experience
and knowledge (otherwise contact an electrician), you can replace power
switches and wall sockets, fit plugs, extension cords and light sockets.
Incorrect installation can result in fatal injury and the risk of fire.
SYMBOLS
| Read the instructions.
---|---
| The product is not dimmable.
| Approved in accordance with the relevant directives.
| Recycle discarded product in accordance with local regulations.
TECHNICAL DATA
Rated voltage | 230 V ~ 50 Hz |
---|---|
Output | 22 W |
Socket | G13 |
Tube type | T8 |
Energy class | E |
Colour temperature | 3000 K |
Luminous flux | 2450 lm |
Power factor | 0.9 |
Colour rendering index | 80 |
Life span | 30000 h |
On/Off | 12500 times |
INSTALLATION
NEW INSTALLATION
**FIG. 1 **
**FIG. 2 **
AFTER INSTALLATION IN LIGHTS WITH CHOKE COIL
Conventional T8 strip light
S = Starter.
**FIG. 3 **
LED strip light
Replace the starter with the LED fuse.
F = LED fuse.
**FIG. 4 **
AFTER INSTALLATION IN LIGHTS WITH ELECTRONIC ACTUATOR
**Conventional T8 strip light**
A = Electronic actuator.
**FIG. 5 **
LED strip light
- Remove the electronic actuator (B) as shown in the figure below.
- Connect a direct wire between pin 2 and 3 on the light.
- Connect pin 1 to the mains phase (L) and pin 4 to neutral (N).
B = Electronic actuator.
**FIG. 6 **
PRODUCT INFORMATION SHEET
Supplier’s name or trademark: | Anslut |
---|---|
Supplier’s address (a): | Jula AB, Julagatan, 2, 53237 Skara, SE |
Model identifier: | 019929 |
Type of light source: | |
Lighting technology used: | LED |
Light source connected to mains supply or light source not connected to mains
supply:| MLS| Connected light source (CLS):| no
Colour-tuneable light source:| no| Envelope:| –
High luminance light source:| no| |
Anti-glare shield:| no| Dimmable:| no
Product parameters
Parameter| Value| Parameter| Value
General product parameters:
Energy consumption in on-mode (kWh/1000 h)| 22| Energy efficiency class| E
Useful luminous flux (Φuse), indicating if it refers to the flux in a sphere
(360˚), in a wide cone (120˚) or in a narrow cone (90˚).| 2 450 in Sphere
(360°)| Correlated colour temperature, rounded to the nearest 100 K, or the
range of correlated colour temperatures, rounded to the nearest 100 K, that
can be set.| 3 000
On-mode power (Pon), expressed in W.| 22,0| Standby power (Psb), expressed in
W and rounded to the second decimal.| ****
0,00
Networked standby power (Pnet) for CLS, expressed in W and rounded to the
second decimal.| –| Colour rendering index, rounded to the nearest integer, or
the range of CRI-values that can be set.| 80
Outer dimensions without separate control gear, lighting control parts and
non-lighting control parts, if any (millimetre).| Height| 28| Spectral power
distribution in the range 250 nm to 800 nm, at full-load.| ****
See image in last page
Width| 28
Depth| 1 500
Claim of equivalent power (c)| –| If yes, equivalent power (W)| –
| | Chromaticity coordinates (x and y)| 0,440
0,400
Parameters for directional light sources:
Peak luminous intensity (cd)| | Beam angle in degrees, or the range of beam angles that can be set|
Parameters for LED and OLED light sources:
R9 colour rendering index value| 2| Survival factor| 0,90
The lumen maintenance factor| 0,96| |
Parameters for LED and OLED mains light sources:
Displacement factor (cos φ1)| 0,89| Colour consistency in mcadam ellipses| 3
Claims that an LED light source replaces a fluorescent light source without
integrated ballast of a particular wattage.| -(b)| If yes then replacement
claim (W)| –
Flicker metric (Pst LM)| 0,0| Stroboscopic effect metric (SVM)| 0,0
Jula reserves the right to make changes.
For latest version of operating instructions, see
www.jula.com