ActronAir PKV720T Weather Hood Kit User Manual

June 1, 2024
ActronAir

ActronAir PKV720T Weather Hood Kit

Specifications

  • Models: PKV720T, PKY820T, PKY960T, PKV850T, PKV960T

Weights (kg):

  • PKV720T: Shipping Nett 37
  • PKY820T: Shipping Nett 21
  • PKY960T: Shipping Nett 54
  • PKV850T: Shipping Nett 24
  • PKV960T: Shipping Nett 62

Optional Weather Hood Assembly Procedures:

Weather Hood Sub-Assembly:

  1. Pre-assemble weather hood centre panels as shown in Step-1 of Fig. 1 below.
  2. Assemble weather hood centre, right side panel, and left side panel as shown in Step-2 of Fig. 1 below.

IMPORTANT NOTE: For proper sealing, PVC closed
cell tape must be applied to adjoining contact edges before
fastening the screws.

Weather Hood Installation

  1. Apply PVC closed cell tape on contact edges of the Weather Hood Assembly as shown in Step-1 below.
  2. Mount weather hood assembly onto the unit, using the screws provided.

FAQ:
Q: Can anyone install the weather hood kit?
A: Only qualified technicians are allowed to perform the installation and commissioning procedures described in the guide. Compliance with WH&S regulations is mandatory during the process.

INSTALLATION AND COMMISSIONING GUIDE

WEATHER HOOD KIT – WHOA8296 / WHOA72 / WHOA8596

MODELS :
PKV720T PKY820T PKY960T PKV850T PKV960T

SAFETY INSTRUCTIONS

Only qualified technicians are allowed to perform the procedures described in this guide.
WH&S regulations must be observed and will take precedent during the installation and commissioning process.

Optional Weather Hood Part Number Model Weights (kg)
Shipping Nett
WHOA8296 PKY820/960T 37
WHOA72 PKV720T 54
WHOA8596 PKV850/960T 62

OPTIONAL WEATHER HOOD MATERIALS (WHOA 8296):

  • 1 Pc – Weather Hood Centre Top Panel
  • 1 Pc – Weather Hood Centre Panel
  • 1 Pc – Weather Hood Right Side Panel
  • 1 Pc – Weather Hood Left Side Panel
  • 1 Roll – PVC Closed Cell Tape
  • 40 Pcs – Stainless Steel Screw 12G x 5/8, #2 Phillips Pan Head

IMPORTANT NOTE
Economy option is available only with Economy Damper on LHS or RHS configuration.
OPTIONAL WEATHER HOOD ASSEMBLY PROCEDURES:

Weather Hood Sub-Assembly:

  1.  Pre-assemble weather hood centre panels as shown in Step-1 of Fig. 1 below.
  2.  Assemble weather hood centre, right side panel and left side panel as shown in Step-2 of Fig. 1 below.

IMPORTANT NOTE:
For proper sealing, PVC closed cell tape must be applied to adjoining contact edges before fastening the screws.

ActronAir-PKV720T-Weather-Hood-Kit-1

WEATHER HOOD INSTALLATION

  1. Apply PVC closed cell tape on contact edges of the Weather Hood Assembly as shown in Step-1 below.
  2.  Mount weather hood assembly onto the unit, using the screws provided, as shown below.

ActronAir-PKV720T-Weather-Hood-Kit-2

Table 1| Suggested Air FilterProvisions| Return/Spill Air Access| Outside AirDuct Spigot
---|---|---|---
MODEL| QTY| Sizes(H x W x T) – mm| Dimensions(H x W) – mm| Dimensions(H x W) – mm
PKY820TPKY960T| 9| 594 x 492 x 96| 1400 x 400| 1258 x 668
PKV720T|  6| 508 x 508 x 102| 1494 x 374| 1498 x 378
PKV850T| 610 x 610 x 102| 1598 x 516| 1602 x 520
PKV960T

OPTIONAL DAMPER WEIGHT & DIMENSIONS

Unit Model Part Number Application * Weight (kg) Dimensions (mm)
PKY820T – PKY960T 3520-012  Outside Air 13.3 600 x 1200 x 165
PKV720T 3520-032 17.1 450 x 1665 x 100
PKV850T – PKV960T 3520-031 21.69 530 x 1642 x 100
  • Weight includes damper and actuator weights

ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Copyright © 2015 Actron Engineering Pty. Ltd. All rights reserved.