KERBL 222005 Heatable Water Bowl with Tube Valve H10 User Guide
Installation Instructions
Attachment Options
The H10 watering basin can be attached to the wall using a suitable means of attachment or directly to pipes with the relevant pipe attachment bracket (#222019).
- Wall installation
- Pipe attachment with #222019
Installation
Installing the basin
The H10 hearable watering basin can be installed on a wall or pipe. Suitable mounting materials must be selected for the installation height. The installation height must be adjusted to the relevant animal breed and application. Installation height approx. 60 – 80 cm.
Connecting the Pipe
The protection plug and the filler plug must be removed from the top and bottom connectors before beginning the pipe connection.
The watering basin can be connected either from below or from above. The watering basin is also suitable for circulation heater systems and can be connected from above and below simultaneously.
Seal all connections!
If the watering basin is only connected from one side the free connection must be sealed with a filler plug. (The filler plug is included in the scope of delivery)
For pressures >3 bar we recommend installing a pressure regulator in the supply pipe in order to be able to regulate the water pressure.
Please adhere to the connection diagram
The supply pipe to the watering basin must be frost-proofed
The supply pipe to the watering basin must be frost-proofed. Please use the relevant KERBL heating cable for this purpose and insulate it in accordance with the guidelines.
The supply pipe to the watering basin must be frost-proofed
The supply pipe to the watering basin must be frost-proofed. Please use the relevant KERBL heating cable for this purpose and insulate it in accordance with the guidelines.
The heating pipes, the insulation and the supply pipes to the watering basis must be protected from browsing.
Electrical Connection for the Heating Element
The 24V power supply must be laid along the existing pipe to the H10 heatable watering basin.
The transformer and frost protection thermostat are not included in the scope of delivery and must be ordered separately. Caution: the heating element has a power input of 80 respectively 50 W. A 200 W transformer must be selected in order to also operate e.g. a 24V KERBL frost protection heating cable.
Note: T he transformer and thus the devices connected to it can be switched on and off automatically using a KERBL frost protection thermostat (#222794). This can save energy and thus cut costs.
The 24V power supply must be connected to the underside of the watering basin through the cable feed-through on the terminal box. Please lay the cable in the terminal box in such a way that the terminal box cover can be screwed on. The feed-through plug for the supply pipe needs to be punctured so that the supply cable can be fed into the terminal box.
The electrical connection may only be carried out by a qualified
electrician. The relevant national regulations and guidelines must be taken
into account.
! Please adhere to the connection diagram
Attaching the Terminal Box Cover
Close the terminal box using the terminal box cover set (#222022) (included). This cover is not installed at the factory and is included in the scope of delivery. The rubber seal must be positioned between the cover and the cast basin. The cover must be screwed on using the screws that are included.
Purging the Water Pipe
The water pipe must be thoroughly purged before it is connected to the water
supply. It is possible for loose processing residue to be located in newly
laid pipes. The pipe valve on the watering basin also needs to be thoroughly
purged before initial operation.
Setting the Flow Rate on the Valve
The H10 heatable watering basin is fitted with a flow rate regulation screw at
the installation elbow that enables regulation of the water flow rate at the
pipe valve. The regulation screw can be set using a no. 6 Allen key or a
10-cent coin (one Eurocent).
Slot horizontal = maximum water flow
Slot vertical = minimum water flow
Caution: Do not remove the regulation screw
Safety Notes
- Protect all electrical supply lines, insulation and heating cables on the pipes from browsing.
- Install a protective bracket on this watering basin in narrow stalls and bays (see item 4)
- Install the transformer and the 230V power cables away from the reach of the animals
- The 230V cable to the transformer must be fused separately
- The electrical installation may only be carried out by a qualified electrician
- Test the functionality of the entire electrical installation before the first frost of the season
- Do not completely unscrew the regulation screw on the valve. There is no limit stop to prevent the regulation screw from being removed!
Maintenance
Changing the Heating Element
In order to remove the enamel inside basin, for example in order to change the
heating element, the pipe valve must be screwed off the installation elbow
using an open-end spanner (SW24). Then release the hexagon bolt on the
underside of the basin using an open-end spanner (SW13). The enamel inner
basin can now be removed without having to remove and therefore re-seal the
installation elbow.
The Basin needs to be cleaned regularly.
The watering basin needs to be cleaned regularly in order allow the animal
optimum water intake. This serves the health of the animals and ensures a
longer lifespan for the watering basin.
Accessories
-
222019 – Pipe attachment bracket, in pairs for a pipe diameter of 1“-3“
-
221971 – Protective bracket for drinking basins Size 2
-
Transformer
222796 – 100 W
222797 – 200 W
222626 – 300 W
222798 – 400 W
-
Antifreeze Thermostat
222794
Replacement Parts
KERBL Art. No. | Description | Quantity |
---|---|---|
6299 | Washer – DIN 125 – A8.4 – A2 | 1 |
6300 | Protective plug for internal thread G1/2“ | 1 |
6301 | Hexagon bolt – ISO 4017 – M8x16-A2 | 1 |
6302 | Cylinder head screw – ISO 4762 – M5x10-A2 | 1 |
22209 | Filler plug for watering basin – G1/2“ | 1 |
221886 | Pipe valve for watering basin | 1 |
222011 | Upper basin for H10, enamel | 1 |
222012 | Lower basin for H10, powder coated in black | 1 |
222006 | Heating element for basin H10 – 50 VA | 1 |
--- | --- | --- |
222007 | Heating element for basin H10 – 80 VA | 1 |
222014 | Mounting clamp for heating element 222013 | 1 |
222015 | Installation elbow with drill hole for regulation screw | 1 |
222018 | Nylon regulation screw with seal for 222015 | 1 |
222022 | Terminal box cover for H10, complete, in polyethylene bag | 1 |
2220141 | PVC plug Ø10mm for H10 | 1 |
2220142 | PVC filler plug Ø8mm for H10 | 1 |
2220143 | Terminal block 2.5mm^2 – 2-pole | 1 |
2220151 | Flat seal for KERBL installation elbow 222015 | 1 |
Connection Diagram – Heatable Watering Basin H10
-
Mains connection 230V fused separately
-
Mains connection, water branch line or circulation system possible
-
Frost protection thermostat 230V KERBL #222794
-
Junction box at least IP54
-
Transformer 230V-> 24V
KERBL #222796 – 100 Watt
KERBL #222797 – 200 Watt
KERBL #222626 – 300 Watt
KERBL #222798 – 400 Watt -
Junction box at least IP54
-
4V supply line for further heatable watering basins or heating cables
-
24V supply line for connection to watering basin
-
Protective sheeting for browsing area
-
Pipe insulation
-
24V frost protection heating cable KERBL #22358; #223581
-
Heatable watering basin
-
Screws
-
Pipe insulation
-
24V frost protection heating cable KERBL #22358; #223581
-
Protective sheeting for browsing area
-
Possible water pipe connection from below, or 2nd connection for circulation systems
Caution! The transformer and the frost protection thermostat are not included in the scope of delivery and need to be ordered separately!
Maximum permissible cable and pipe length Imax in metres, depending on nominal line section in mm². For a maximum voltage drop of 15% and a parallel connection
Line section in mm²| Maximum line length in metres
1,5| 50
2,5| 80
Guarantee Card
Based on our General Terms and Conditions we provide a 2-YEAR GUARANTEE for this product for the resolution of damage caused by defective materials or manufacturing defects. The guarantee term is valid from the date of purchase. The guarantee does not cover:
- Damage caused by natural wear and tear (wearing parts, sliding parts), overloading or incorrect operation.
- Damaged caused by an Act of God or during transportation.
- Damage to rubber parts, e.g. on connection wires. Guarantee repairs are only carried out at the manufacturing works or an authorised repair
shop! The manufacturer reserves the right to refuse any guarantee claim in cases of non-compliance. For this purpose the equipment must be returned to the point of sale in one piece, packaged and postage paid with the original invoice and the guarantee card. Please give details of the nature of your complaint. The owner of the equipment will carry costs that arise from unjustified complaints.
Albert KERBL GmbH hereby declares that the product / device described in these instructions complies with the fundamental requirements and other relevant stipulations and regulations. The CE-/UCKA-mark confirms compliance with the Directives of the European Union or the relevant UK legislation.
Albert Kerbl GmbH
Felizenzell 9
84428 Buchbach, Germany
Tel. +49 8086 933 – 100
Fax +49 8086 933 – 500
info@kerbl.de
www.kerbl.de
Kerbl Austria Handels GmbH
Wirtschaftspark 1
9130 Poggersdorf
Tel. +43 4224 81555
Fax. +43 4224 81555-629
order@kerbl-austria.at
www.kerbl-austria.at
Kerbl France Sarl
3 rue Henri Rouby, B.P 46 Soultz
68501 Guebwiller Cedex, France
Tel. : +33 3 89 62 15 00
Fax : +33 3 89 83 04 46
info@kerbl-france.com
www.kerbl-france.com
Kerbl UK Ltd
Lands End Way Oakham, Rutland
LE15 6RF, UK
Phone +44 (0) 1572 722558
Fax +44 (0) 1572 757614
www.kerbl.co.uk
References
- Home - www.austria.at
- France.fr : Explore France and its wonders - Explore France
- Everything around animal breeding, husbandry and agricultural supplies - Albert Kerbl GmbH
- Page d'accueil - Kerbl France
- Home - Kerbl UK Ltd
- Everything around animal breeding, husbandry and agricultural supplies - Albert Kerbl GmbH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>