Installation Instructions

Attachment Options

The H10 watering basin can be attached to the wall using a suitable means of attachment or directly to pipes with the relevant pipe attachment bracket (#222019).

  • Wall installationInstallation Instruction
  • Pipe attachment with #222019
    Installation Instruction

Installation

Installing the basin

The H10 hearable watering basin can be installed on a wall or pipe. Suitable mounting materials must be selected for the  installation height. The installation height must be adjusted to the relevant animal breed and application. Installation height approx. 60 – 80 cm.

Installation Instruction

Connecting the Pipe

The protection plug and the filler plug must be removed from the top and bottom connectors before beginning the pipe connection.

The watering basin can be connected either from below or from above. The watering basin is also suitable for circulation heater systems and can be connected from above and below simultaneously.

Seal all connections!

If the watering basin is only connected from one side the free connection must be sealed with a filler plug. (The filler plug is included in the scope of delivery)

For pressures >3 bar we recommend installing a pressure regulator in the supply pipe in order to be able to regulate the water pressure.

Please adhere to the connection diagram

The supply pipe to the watering basin must be frost-proofed

The supply pipe to the watering basin must be frost-proofed. Please use the relevant KERBL heating cable for this purpose and insulate it in accordance with the guidelines.

The supply pipe to the watering basin must be frost-proofed

The supply pipe to the watering basin must be frost-proofed. Please use the relevant KERBL heating cable for this purpose and insulate it in accordance with the guidelines.

The heating pipes, the insulation and the supply pipes to the watering basis must be protected from browsing.

Electrical Connection for the Heating Element

The 24V power supply must be laid along the existing pipe to the H10 heatable watering basin.

The transformer and frost protection thermostat are not included in the scope of delivery and must be ordered separately. Caution: the heating element has a power input of 80 respectively 50 W. A 200 W transformer must be selected in order to also operate e.g. a 24V KERBL frost protection heating cable.

Note: T he transformer and thus the devices connected to it can be switched on and off automatically using a KERBL frost protection thermostat (#222794). This can save energy and thus cut costs.

The 24V power supply must be connected to the underside of the watering basin through the cable feed-through on the terminal box. Please lay the cable in the terminal box in such a way that the terminal box cover can be screwed on. The  feed-through plug for the supply pipe needs to be punctured so that the supply cable can be fed into the terminal box.

The electrical connection may only be carried out by a qualified electrician. The relevant national regulations and guidelines must be taken into account.

! Please adhere to the connection diagram
Installation Instruction

Attaching the Terminal Box Cover

Close the terminal box using the terminal box cover set (#222022) (included). This cover is not installed at the factory and is included in the scope of delivery. The rubber seal must be positioned between the cover and the cast basin. The  cover must be screwed on using the screws that are included.

Purging the Water Pipe
The water pipe must be thoroughly purged before it is connected to the water supply. It is possible for loose processing residue to be located in newly laid pipes. The pipe valve on the watering basin also needs to be thoroughly purged before initial operation.

Setting the Flow Rate on the Valve
The H10 heatable watering basin is fitted with a flow rate regulation screw at the installation elbow that enables regulation of the water flow rate at the pipe valve. The regulation screw can be set using a no. 6 Allen key or a 10-cent coin (one Eurocent).

Slot horizontal = maximum water flow
Slot vertical = minimum water flow

Caution: Do not remove the regulation screw

Safety Notes

  • Protect all electrical supply lines, insulation and heating cables on the pipes from browsing.
  • Install a protective bracket on this watering basin in narrow stalls and bays (see item 4)
  • Install the transformer and the 230V power cables away from the reach of the animals
  • The 230V cable to the transformer must be fused separately
  • The electrical installation may only be carried out by a qualified electrician
  • Test the functionality of the entire electrical installation before the first frost of the season
  • Do not completely unscrew the regulation screw on the valve. There is no limit stop to prevent the regulation screw from being removed!

Maintenance

Changing the Heating Element
In order to remove the enamel inside basin, for example in order to change the heating element, the pipe valve must be screwed off the installation elbow using an open-end spanner (SW24). Then release the hexagon bolt on the underside of the basin using an open-end spanner (SW13). The enamel inner basin can now be removed without having to remove and therefore re-seal the installation elbow.

The Basin needs to be cleaned regularly.
The watering basin needs to be cleaned regularly in order allow the animal optimum water intake. This serves the health of the animals and ensures a longer lifespan for the watering basin.

Accessories

  • 222019 – Pipe attachment bracket, in pairs for a pipe diameter of 1“-3“

  • 221971 – Protective bracket for drinking basins Size 2

  • Transformer

    222796 – 100 W

    222797 – 200 W

    222626 – 300 W

    222798 – 400 W

  • Antifreeze Thermostat

    222794

Replacement Parts

Replacement Parts

KERBL Art. No. Description Quantity
6299 Washer – DIN 125 – A8.4 – A2 1
6300 Protective plug for internal thread G1/2“ 1
6301 Hexagon bolt – ISO 4017 – M8x16-A2 1
6302 Cylinder head screw – ISO 4762 – M5x10-A2 1
22209 Filler plug for watering basin – G1/2“ 1
221886 Pipe valve for watering basin 1
222011 Upper basin for H10, enamel 1
222012 Lower basin for H10, powder coated in black 1
222006 Heating element for basin H10 – 50 VA 1
--- --- ---
222007 Heating element for basin H10 – 80 VA 1
222014 Mounting clamp for heating element 222013 1
222015 Installation elbow with drill hole for regulation screw 1
222018 Nylon regulation screw with seal for 222015 1
222022 Terminal box cover for H10, complete, in polyethylene bag 1
2220141 PVC plug Ø10mm for H10 1
2220142 PVC filler plug Ø8mm for H10 1
2220143 Terminal block 2.5mm^2 – 2-pole 1
2220151 Flat seal for KERBL installation elbow 222015 1

Connection Diagram – Heatable Watering Basin H10
Connection Diagram

  1. Mains connection 230V fused separately

  2. Mains connection, water branch line or circulation system possible

  3. Frost protection thermostat 230V KERBL #222794

  4. Junction box at least IP54

  5. Transformer 230V-> 24V
    KERBL #222796 – 100 Watt
    KERBL #222797 – 200 Watt
    KERBL #222626 – 300 Watt
    KERBL #222798 – 400 Watt

  6. Junction box at least IP54

  7. 4V supply line for further heatable watering basins or heating cables

  8. 24V supply line for connection to watering basin

  9. Protective sheeting for browsing area

  10. Pipe insulation

  11. 24V frost protection heating cable KERBL #22358; #223581

  12. Heatable watering basin

  13. Screws

  14. Pipe insulation

  15. 24V frost protection heating cable KERBL #22358; #223581

  16. Protective sheeting for browsing area

  17. Possible water pipe connection from below, or 2nd connection for circulation systems

Caution! The transformer and the frost protection thermostat are not included in the scope of delivery and need to be ordered separately!

Maximum permissible cable and pipe length Imax in metres, depending on nominal line section in mm². For a maximum voltage drop of 15% and a parallel connection

Line section in mm²| Maximum line length in metres
1,5| 50
2,5| 80

Guarantee Card

Based on our General Terms and Conditions we provide a 2-YEAR GUARANTEE for this product for the resolution of damage caused by defective materials or manufacturing defects. The guarantee term is valid from the date of purchase. The guarantee does not cover:

  1. Damage caused by natural wear and tear (wearing parts, sliding parts), overloading or incorrect operation.
  2. Damaged caused by an Act of God or during transportation.
  3. Damage to rubber parts, e.g. on connection wires. Guarantee repairs are only carried out at the manufacturing works or an authorised repair

shop! The manufacturer reserves the right to refuse any guarantee claim in cases of non-compliance. For this purpose the equipment must be returned to the point of sale in one piece, packaged and postage paid with the original invoice and the guarantee card. Please give details of the nature of your complaint. The owner of the equipment will carry costs that arise from unjustified complaints.

Albert KERBL GmbH hereby declares that the product / device described in these instructions complies with the fundamental requirements and other relevant stipulations and regulations. The CE-/UCKA-mark confirms compliance with the Directives of the European Union or the relevant UK legislation.

Albert Kerbl GmbH
Felizenzell 9
84428 Buchbach, Germany
Tel. +49 8086 933 – 100
Fax +49 8086 933 – 500
info@kerbl.de
www.kerbl.de

Kerbl Austria Handels GmbH
Wirtschaftspark 1
9130 Poggersdorf
Tel. +43 4224 81555
Fax. +43 4224 81555-629
order@kerbl-austria.at
www.kerbl-austria.at

Kerbl France Sarl
3 rue Henri Rouby, B.P 46 Soultz
68501 Guebwiller Cedex, France
Tel. : +33 3 89 62 15 00
Fax : +33 3 89 83 04 46
info@kerbl-france.com
www.kerbl-france.com

Kerbl UK Ltd
Lands End Way Oakham, Rutland
LE15 6RF, UK
Phone +44 (0) 1572 722558
Fax +44 (0) 1572 757614
www.kerbl.co.uk

KERBL Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals