Telran NP-L500W Outdoor Magnetic Lock User Guide
- June 13, 2024
- TELRAN
Table of Contents
Telran NP-L500W Outdoor Magnetic Lock User Guide
Instructions For Magnetic Locking Devices
*Technical Parameters
A. Holding power: 500KGS
B. Working Voltage: 12VDC
C. Working Current: 320mA
D. Safety mode: Power-on to lock, Power-off to open.
E. Typical Installation: Flushing (A), Hanging (G)
F. Append: LED (D), Time Delay Opening (X), For Feedback (F)
*Installation chart
* Typical Installation:
STEP 1
A. Fold template along dotted line.
B. Place template against door and head frame.
C. Drill holes as indicated on temple.
STEP 2
A. Mount the armature plate to door using I rubber washer sandwiched between 2
steel washer (the rubber washer
and 2 steel washer are installed on the through sex nut between the armature
plate and door).
STEP 3
A. Install the mounting plate with 2 flat head screws (the 2 M5X5 flat head
screws are installed in the slotted holes for adjustment).
B. Adjust mounting plate so that it forms right angle with the armature plate.
C. Using the mounting plate as a temple, drill the wire hole.
D. Drill and remaining mounting screws.
STEP4
A. Install magnet to mounting plate with 2 M4 screws supplied.
* Armature Plate Mounts To The Door:
Important: Fix the armature plate not too tightly. and make the rubber washer more nexible, in order to make the armature plate automatically adjust its proper position with magnet.
* 12VDC Input:
A. Connect the positive (+) lead from a 12VDC power source to line Red.
B. Connect the ground (-) lead from a 12VDC power source to line Black.