SATCO 65-781R2 LED UFO High Bay Instruction Manual
- June 13, 2024
- SATCO
Table of Contents
LED UFO HIGH BAY
Models:
65-781R2, 65-782R2, 65-783R2, 65-784R2,
65-791R2, 65-792R2, 65-793R2, 65-794R2,
65-801R2, 65-802R2, 65-803R2, 65-804R2:
ø11″ (280±5mm)
65-784R2, 65-785R2, 65-787R2, 65-788R2,
65-795R2, 65-796R2, 65-797R2, 65-798R2,
65-805R2, 65-806R2, 65-807R2, 65-808R2:
ø13.4″ (340±5mm)
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing fixture. Retain for future reference.
WARNING: Risk of Fire or Electric Shock
- To avoid damage, falling, electric shock or fire, do not modify the lamp or replace accessories without confirming with the supplier first.
- Only authorized, qualified personnel should install this fixture and should follow the owner’s manual. Any improper installation might cause failure, electric shock, fire or other injury, damage or hazard.
- Disconnect power before installation or any maintenance of the fixture.
- Do not dismantle the fixture without the supplier’s authorization.
- Do not touch the power supply when the fixture is operating.
- The external flexible cable or cord of this fixture cannot be replaced; if the cord is damaged, the fixture shall be destroyed.
- Terminal block not included. The electrical fitting must be installed by a licensed electrician.
- For use in environments where an accumulation of non-conductive dust on the fixture may be expected.
IMPORTANT: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
SPECIFICATIONS
Model | CCT | Volts | Operating Temperature |
---|---|---|---|
65-781R2 | 4000K | 100-277V | -40°C to +45°C (-40°F to +113°F) |
65-782R2 | 5000K | ||
65-783R2 | 4000K | ||
65-784R2 | 5000K | ||
65-785R2 | 4000K | ||
65-786R2 | 5000K | ||
65-787R2 | 4000K | ||
65-788R2 | 5000K | ||
65-791R2 | 4000K | ||
65-792R2 | 5000K | ||
65-793R2 | 4000K | ||
65-794R2 | 5000K | ||
65-795R2 | 4000K | 4000K | -40°C to +45°C (-40°F to +113°F) |
65-796R2 | 5000K | 5000K | |
65-797R2 | 4000K | 4000K | |
65-798R2 | 5000K | 5000K | |
65-801R2 | 4000K | 4000K | |
65-802R2 | 5000K | 5000K | |
65-803R2 | 4000K | 4000K | |
65-804R2 | 5000K | 5000K | |
65-805R2 | 4000K | 4000K | |
65-806R2 | 5000K | 5000K | |
65-807R2 | 4000K | 4000K | |
65-808R2 | 5000K | 5000K |
WIRING DIAGRAM & INSTRUCTIONS
The LED high bay light can be equipped with an optional DC motion sensor (86/218 microwave sensor, 86/217 – 6m mounting height or 86/220 -12m mounting height PIR sensors). The sensor needs to be set via remote (86/219). For standard 0-10V dimming applications, see wiring diagram.
INSTALLATION: Hook Mount
STEP 1: Screw the hook into the fixture, tighten and secure.
STEP 2: Hang the fixture on the ceiling hook or chain.
STEP 3: Connect wires using the wiring diagram and instructions on page 1. Make sure connections are capped and sealed.
INSTALLATION: Ceiling Mount
STEP 1: Use a pen or sharp tool and mark holes through the mounting
surface on the ceiling and drill holes. Fix screws into the holes with a
hammer.
STEP 2: Align the bracket hole with screw hole nd push the fixture to one side and secure.
STEP 3: Connect wires using the wiring diagram and instructions on page
- Make sure connections are capped and sealed.
NOTE: By adjusting the bracket screws, the fixture can be angled 50° to the left or right vertically.
Optional DC Motion Sensor
Motion sensor installation does not require tools.
NOTE: The motion sensor has no dialing code. A remote control (86/219) is needed for adjustment. Refer to remote control instructions for adjustments.
If motion sensor is not desired, unscrew the motion sensor and replace it with a protective cover.