Maintenance step

  1. Remove the rotating assembly along the reverse side of the light outletDEWALT DW074LR T2 Red Rotary Laser - Maintenance
  2. Remove the rubber sleeve from the bracketDEWALT DW074LR T2 Red Rotary Laser - Maintenance 1
  3. Remove 4 screws to take off Connecting PlateDEWALT DW074LR T2 Red Rotary Laser - Maintenance 2
  4. Remove 4 screws and 3 self-tapping screws to take off top cover.DEWALT DW074LR T2 Red Rotary Laser - cover
  5. Remove 4 screws and 3 self-tapping screws to take off Mid Section.DEWALT DW074LR T2 Red Rotary Laser - Mid Section
  6. Below is a list of the main parts. Replace or repair these parts according to the troubleshooting section.DEWALT DW074LR T2 Red Rotary Laser - Mid Section 1
907250 NRL-MB-005_A11 Main PCBA DCE074R T
907251 NRL-MB-005_A12 Main PCBA DW074R T2

DEWALT DW074LR T2 Red Rotary Laser - Mid Section 2

Defect Troubleshooting Main Part
Horizontal application defective Check x-axis and y-axis bubble circuit board

connection
cable ,or replace the Membrane Switch| 906139 OPP2-keypad-001 Membrane Switch
Calibration can’t saved| Replace the storage IC| Main PCBA
Calibration limit beyond precision scope| Adjust the compensation glass| /
Weak beam| Replace the laser| 907257 OPP-01-01 88 Main Laser Module (DW074LR)
906482 MPP-01-01 88 Main Laser Module (DCE074LR)
Uneveling| Replace stepping motor| 904290 NRL800HT-01-02 04 Stepper Motor
Light is out of working| Replace the Membrane Switch| 906139 OPP2-keypad-001 Membrane Switch
Unit won’t receive remote control signal.| Check receiver connection cable| /
Vertical application defective| Check z-axis bubble circuit board connection cable ,or replace the Membrane Switch| 906139 OPP2-keypad-001 Membrane Switch
Rotation head loose from frame.| Fasten the screw| /
Battery indicator lights flash| Battery voltage is low, need to recharge| /
No alarm| Replace Main PCBA| Main PCBA
Button doesn’t work| Data cable looses ,reinstall the data cable| /
Scan function defective| Replace Counter Photo-Eye PCBA| 905243 NRL-ECV-001 A20 Counter Photo-Eye PCBA
Slope out of tolerance| Loosen the four M2.5 screws on the Main PCBA. Move the Main PCBA left or right to correct the slope. Tighten the screws.| /
Unable to enter the calibration mode| Replace main PCBA| Main PCBA

Calibration Instruction

  1. Install the battery, long press the SLOPE BUTTON , meanwhile short press the POWER BUTTON   . Hold the SLOPE BUTTON until POWER BUTTON released. All the indicators will light up , indicating instrument is in calibration mode;
  2. When enter calibration mode, the unit will auto select X direction. Calibrate the laser through UP/DWON BUTTON .   Press and hold Slope button to save the calibration value. The rotating laser will flash 3 times.
  3. Press and hold RPM BUTTON   (Press time≥3s) to switch to Y axis. Repeat STEP2 to calibrate Y axis. The two values in X and Y need to be saved separately.
  4. Short press to exit the calibration mode or power off the rotary directly.