INTRODUCTION

The versatile ADP-26 is part of the ADP Self powered, DSP integrated Series. It has been designed to offer the utmost sound reinforcement reliability, incorporating the latest acoustical and electronical technology and delivering incredible, dynamic sound.
The ADP-26 is an extremelly high power, two way full range cabinet providing exceptional performance. Each cabinet has a DSP integrated for system protection and optimization. This DSP applies linear phase (FIR) and classic crossovers.
Other features include temperature sensor, Ethernet options and many more.
The compact ADP-26 has an unbeatable power to size ratio, there is no need for external amplification racks, is very light weight and is the ideal solution for portable or fixed sound reinforcement. A variety of rigging options make the ADP-26 easy to set-up in minimal time. To extend the low frequency response, the ADP-18S subwoofer cabinet can be used.
To facilitate, correct and reliable use of the powered cabinet ADP-26 we have designed this instruction manual. Please read the manual carefully before proceeding to install the system.
Please observe the technical data carefully and do not ignore the instructions included within this manual.
Before starting to use this device, please read this instruction manual carefully.
Keep these instructions in the place where the equipment will be used and with easy access to them.

| • Electrical appliance
The exclamation mark within a triangle identifies the presence of electricity. Use the system carefully without wet hands or feet. Avoid installing the speaker in wet or excesivelly humid places. Do not place material that contains liquid on or near the unit. Avoid dripping or splashing water or any liquid over the unit. Regularly check the condition of the cables and make sure these are not being walked on or pinched. Connect the speaker to bipolar, earthed
mains. The mains plug must be connected to the appropriate protection (fuse or breaker). Connection to any other type of mains could result in an electrical shock and violate local electrical codes.
CAUTION: DO NOT CONNECT OR DISCONNECT THE AC POWER CONNECTORS UNDER LOAD.
---|---
| • Heavy equipment
Apply back protection when using the system. Avoid loading and unloading at heights.
| • Electrical shock risk
The diagonal mark within a triangle identifies the presence of dangerous voltage.
Do not open or handle the interior of the box. These parts are not to be adjusted by the user. For maintenance and/ or repair please go to an authorized service centre.In order to reduce the risk of electric shock, disconnect from AC before plug in or unplugging Audio signal cables. Reconnect to AC only if all signal connections are made and secured. Never manipulate the ground type plug provided.
The AC mains plugs should always remain accessible for operation.
Unplug the loudspeaker during storms or when it’s being used for a long time.
| • Hearing damage risk
These systems can reproduce large quantities of sound pressure which can damage hearing. Take precautions if you are going to be near them for extended amounts of time and do not get too close.
| • Hanging / Flying
Do not hang the cabinets from the handles or from any other part other than the designated hanging point. When flying this system please observe the technical and “Rainbow” software data carefully. Never exceed the maximum safe working loads or ignore the instructions included within this manual. Use Only flying accessories provided by Lynx Pro Audio S.L. Rigging must be always carried out by professionals.
| • Delicate Material
Please ensure no foreign object or water enters the speaker. Only clean the unit with dry cloths. Do not use solvents.
| • Overheating / Fire risk
To reduce the risk of the speaker over heating, avoid direct contact with sunlight. Avoid placing the unit close to heat inducing objects such as radiators. Do not cover the equipment in use and do not block any ventilation openings.
Do not put naked flame, such as lighted candles, close or on top of the unit.
| • Electromagnetic and interferente emissions
Avoid placing objects which through electromagnetic waves can damage the unit, such as mobile phones, lap tops, magnetic strip cards etc.
This system complies with normatives
EN 55103-1 (1)
EN 55103-2 (2)
(1) This device may not cause harmful interferences.
(2) This device may receive interference including interferences that may cause undesired working.
| •IMPORTANT NOTE
This Equipment must be used in accordance with these instructions and by trained professional personnel only.
This equipment should not be used in places with extreme tropical climates. Don’t expose this apparatus to extreme humidity and or temperature values.

SYSTEM OVERVIEW

  • ADP-26
    High Output, self-powered (Class D switch mode power supply), two-way cabinet.
    Consists of two 6” (1.5” voice coil) neodymium magnet transducers with aluminium demodulating rings and a 1” compression driver with titanium diaphragm, mounted on a 90ºH x 60ºV rotatable, exponential horn.
    DSP (FIR technology) controlled with 1000W amplification, 127dB SPL.

  • Technical Data:
    Components:
    •HF
    •LF/MF| 1” titanium diaphragm driver
    2 x 6” neodymium (aluminium demodulating rings)
    ---|---
    Frequency range:| 65 Hz – 20 KHz (-10dB)
    Frequency response:| 75 Hz – 18 KHz (± 3dB)
    Max SPL / Peak:| 124 dB – 127 dB peak
    Coverage angle:| 90º H x 60º V rotatable horn
    Power amplifier:| 1000W Class D
    LF/MF amplifier: 1 x 500 W
    HF amplifier: 1 x 500 W
    Processing:| 56 bit Lynx DSPB-22 with FIR filters
    Cabinet adjustment:| Back panel LCD
    Control connections:| XLR / Ethernet (OCS) optional, USB (DSP programming)
    AC power:| 230V / 115V selectable. 50/60 Hz 5A
    AC connections:| 16A Neutrik powerCon TRUE1 with link output
    Finish:| Polyurea coating high grade resistant paint
    Material:| 15 mm Premium birch plywood
    Dimensions:| 530 x 222 x 269 mm (H x W x D)
    Weight:| 13kg (28 lbs)

  • ADP-26 measurementsLYNX ADP 26 Class Powered Cabinet - measurements

  • ADP-26 back panelLYNX ADP 26 Class Powered Cabinet - measurements 1

CONNECTORS AND CONNECTIONS

SOCKET POWERCON CONNECTORSLYNX ADP 26 Class Powered Cabinet - measurements
2XLR SOCKET CONNECTORSLYNX ADP 26 Class Powered
Cabinet - measurements 3XLR AEREAL CONNECTORSLYNX ADP 26 Class Powered Cabinet - measurements
4

  • CONNECTION EXAMPLE: 6 ADP-26 cabinets

LYNX ADP 26 Class Powered Cabinet - measurements 5 CAUTION:
Do not connect or disconnect the AC power connectors underload.
From the buttons below the display on the cabinet’s back panel you are able to configure the Basic adjustment functions of the internal DSP. Depending on the model, you can find the following configurations:

Preset Display Name Additional info
1 FIR FULL RANGE Full range with FIR filters
2 FIR X80Hz 80 Hz high pass with FIR filters
3 FIR X90Hz 90 Hz high pass with FIR filters
4 FIR X100Hz 100 Hz high pass with FIR filters
5 FIR FULL R INV Full range inverted with FIR filters
6 FIR X80Hz INV 80 Hz high pass inverted with FIR filters
7 FIR X90Hz INV 90 Hz high pass inverted with FIR filters
8 FIR X100Hz INV 100 Hz high pass inverted with FIR filters
9 FIR FULL R -6 Full range -6dB with FIR filters
10 FIR FR -6 INV Full range inverted -6dB with FIR filters
11 FULL RANGE Full range
12 X80Hz 80 Hz high pass
13 X90 Hz 90 Hz high pass
14 X100 Hz 100 Hz high pass
15 FULL R INV Full range inverted
16 X80 Hz INV 80 Hz high pass inverted
17 X90 Hz INV 90 Hz high pass inverted
18 X100 Hz INV 100 Hz high pass inverted
19 FULL R -6 Full range -6dB
20 FULL R -6 INV Full range inverted -6dB

Note:
You must apply the desired configuration in each one cabinet. This is done via the buttons located on the back panel of the cabinet and requires electrical power to work.
FIR FILTERS
Finite Impulse Response (FIR) filters are used in the signal processing of the ADP-215 cabinet. FIR is a type of digital filter with linear phase characteristics. This frees system designers from the constraints of phase anomalies associated with analogue filters or their digital versions (IIR, Infinite Impulse Response). When properly used, FIR filtering can audibly improve a system’s impulse response and reduce crossover interference.

CONFIGURATION PANEL

On the back panel you will see 3 buttons and an information screen, on which you can read the established parameters and information such as amplification module temperature, input signal level and name of the current preset (Fig1).
If changes are not made the display will automatically dim to save energy and avoid unnecessary light in situations where light is not wanted. To re- activate the light simply press the OK button.

SELECT THE INPUT: DIGITAL OR ANALOG

To change the preset configuration just press the up button (Fig2(1)) and down button (Fig2(2)) until you see the title and preset number required.
Once found, press OK (Fig2(3)) until the progress bar finishes (Fig3). The display will indicate “Loading DSP” (Fig4).![LYNX ADP 26 Class Powered Cabinet

ONLINE CONTROL SYSTEM

  • Who is it for?
    Users of Self powered DSP incorporated Lynx Pro Audio Cabinets where the user has requested the cabinets be supplied with the Ethernet Module kit.

  • What is it for?
    Obtain detailed information of cabinet behaviour and monitor the cabinet/s in real time. You can change the preset, gain, mute, polarity and phase. You can also activate the air absorption compensation and select the «SOLO» mode.

  • How does it work?
    Via Ethernet (cable or wireless). Once installed, the O.C.S. software automatically detects all the cabinets connected to the network and displays them in the O.C.S. window on the users PC.

  • What does it show?
    As well as displaying the cabinet model and IP address the O.C.S will be monitoring in real time and the user will be able to view RMS levels, Input clip, power module temperature, compression levels, air absorption compensation and cabinet angulation.

LYNX ADP 26 Class Powered Cabinet - SYSTEM

RAINBOW 3D Acoustic Prediction Software

Lynx Pro Audio’s R&D department is working on Rainbow 3D, a new acoustic simulation software with dynamic 3D features. With a sophisticated design, Rainbow 3D stands out for its speed, being able to provide a simulation in just a few seconds. It also provides algorithms for beam steering and optimizing the listening area.

  • Designed from scratch by professionals
    Rainbow 3D has been programmed from scratch by Lynx Pro Audio engineers, using new programming procedures that achieve an effective simulation with really low calculation time.

  • Multiple listening zones
    The program can simulate all Lynx Pro Audio’s acoustic enclosures located in a 3D space, including the classic side, top and front views. It can also define multiple listening zones and allows offset positioning and symmetry. Blueprint images, textures and PNG format pictures can be imported.

  • Unlimited sound sources
    Allows the acoustic simulation for an unlimited number of sound sources and audio systems. You can place as many systems (subwoofers, line arrays, columns and individual boxes) as you desire. Also, the line arrays can be placed in stack or flown configuration.

  • Beam steering
    Rainbow 3D has the ability to add DSP processing to the simulation and uses algorithms to control the directivity (beam steering) in columns, without the need to tilt them physically, being able to divide the column into several beams that point to different zones.

  • Accurate optimization thanks to FIR filters
    Optimized algorithms are used in the listening area to improve the sound coverage and the frequency response. This feature can be executed in a matter of seconds. Additionally, the export of FIR coefficients can be performed with the optimization for later loading in the DSP via Ethernet or a USB device. In the near future direct communication with Lynx Pro Audio and OCS will be available.

  • Multiple measures and tools
    Likewise, the R&D department is developing multiple measurement and analysis tools for the calculated data. For example, the sound pressure curves (SPL) in the listening areas and the capture of virtual measurements that show the frequency response in the points of location indicated and added. Among other tools you will find autosplay and a wizard to set up different subwoofer arragements.

LYNX ADP 26 Class Powered Cabinet - SYSTEM 1

HARDWARE AND ACCESSORIES

The ADP series include some accessories for installation, rigging and transport. The ADP-26 includes:LYNX ADP 26 Class Powered Cabinet -
ACCESSORIES

****DECLARATION OF CONFORMITY
Lynx Pro Audio S.L.
Calle 1 – Pol. Ind. Picassent
46220 Picassent (Valencia)
SPAIN – EU
Tel.: (+34) 961 10 96 01
www.lynxproaudio.com

Lynx Pro Audio S.L. declares that ionic series are in conformity with the following EC directives:

Low Voltage Directive 2006/95/EC
Electromagnetic Compatibility EMC 2004/108/EC
RoHS Directive 2002/95/EC

In accordance with Harmonized European Norms:

EN 60065:2002| Audio, video and similar electronic apparatus. Safety requirements
---|---
EN 55103-1:1996|  Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use.
Part 1: Emission.
EN 55103-2:1996|  Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use.
Part 2: Immunity.
ADP models:| ADP-215 / ADP-15 / ADP-12 / ADP-26 / ADP-212M / ADP-12M /   ADP- 18S / ADP-12S

LYNX PRO AUDIO GUARANTEE
Lynx products are guaranteed against every kind of manufacturing fault 3 year after the date of sale. When products are under guarantee, the repairing and the free supplying of the device parts in order to correct any kind of defect are guaranteed by Lynx Pro Audio S.L. In the case that the product could not be returned to the factory for checking and repairing, Lynx Pro Audio S.L. would supply all the necessary parts.
Lynx Pro Audio S.L. is not responsible for any damage or defect caused during the transport or caused by an undue or improper handling y a non-authorized person during the life of this guarantee.
All our products undergo rigorous tests and quality controls. We guarantee the characteristics described here within and their quality against any fabrication defect.
The user loses all warranty rights if he incorporates or carries out any modification to the product, if he uses it outside of the stated safe working loads or does not secure the system properly using all the pins in their corresponding holes.
For any question regarding the product, the user must quote the model and serial number.
WEEE Declaration: Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime. Please dispose of this product according to the respective national regulations or contractual agreements.
If there are any further questions concerning the disposal of this product please contact Lynx Pro Audio S.L.

Lynx Pro Audio S.L
www.lynxproaudio.com

Documents / Resources

| LYNX ADP-26 Class Powered Cabinet [pdf] User Manual
ADP-26 Class Powered Cabinet, ADP-26, Class Powered Cabinet, Powered Cabinet, Cabinet
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals